Alessio Capecchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alessio Capecchi has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Arianna Menciassi
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
1 shared publication - Federica Semproni
BioRobotics Institute, Scuola SuperioreSant’Anna, Pontedera (Pisa), Italy
1 shared publication - Veronica Iacovacci
The Biorobotics Institute Scuola Superiore Sant’Anna Viale Rinaldo Piaggio 34 56025 Pontedera Italy
1 shared publication
Latest Publications
- Open Access
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (3) , 1341-1348
Optimization and Validation of an Artificial Bladder Design Through Finite Element Analysis to Meet Clinical Requirements
Bladder cancer and urinary dysfunctions present significant challenges to patient health and quality of life. Considering that radical cystectomy remains the standard treatment for muscle-invasive bladder cancer, there is an urgent need for the implantation of artificial bladders (ABs). In this study, we present the optimization and validation of a novel, collapsible, origami-based AB through Finite Element Method (FEM) simulations. We evaluated various materials and wall thicknesses to improve unfolding capability and minimize structural stress concentrations. Simulations were conducted under different filling conditions, replicating the in-body constraints posed by surrounding organs. The optimal materialthickness combination, namely MoldStar 15 with a 2:1 wall-tofold ratio, effectively maintained low intravesical pressures during filling (0.5-1.96 kPa), meeting the clinical requirements for renal function preservation. Stress analysis showed Von Mises stresses lower than 2.5 MPa, well below the materials tensile stress limit, thus ensuring the structural integrity of the device. The AB model was validated by comparing FEM simulation results with a physical prototype, showing a pressure difference of approximately 15% and a volumetric overlap deviation under 10%.
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (3) , 1341-1348
Open AccessOptimization and Validation of an Artificial Bladder Design Through Finite Element Analysis to Meet Clinical Requirements
Bladder cancer and urinary dysfunctions present significant challenges to patient health and quality of life. Considering that radical cystectomy remains the standard treatment for muscle-invasive bladder cancer, there is an urgent need for the implantation of artificial bladders (ABs). In this study, we present the optimization and validation of a novel, collapsible, origami-based AB through Finite Element Method (FEM) simulations. We evaluated various materials and wall thicknesses to improve unfolding capability and minimize structural stress concentrations. Simulations were conducted under different filling conditions, replicating the in-body constraints posed by surrounding organs. The optimal materialthickness combination, namely MoldStar 15 with a 2:1 wall-tofold ratio, effectively maintained low intravesical pressures during filling (0.5-1.96 kPa), meeting the clinical requirements for renal function preservation. Stress analysis showed Von Mises stresses lower than 2.5 MPa, well below the materials tensile stress limit, thus ensuring the structural integrity of the device. The AB model was validated by comparing FEM simulation results with a physical prototype, showing a pressure difference of approximately 15% and a volumetric overlap deviation under 10%.