AWAnjing Wang

Anjing Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anjing Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Dacheng Li

    Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China

    3 shared publications
  • Fangxiao Cui

    Anhui Province Key Laboratory of Optical Quantitative Remote Sensing, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

    2 shared publications
  • Jun Wu

    Anhui Province Key Laboratory of Optical Quantitative Remote Sensing, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

    2 shared publications
  • Yangyu Li

    Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China

    2 shared publications
  • Aohua Li

    School of Mechanical Engineering, Hefei University of Technology, Hefei 230009, China

    1 shared publication
  • Fengxiang Ma

    Electric Power Research Institute of State Grid Anhui Electric Power Company, Ltd., Hefei, China

    1 shared publication

Latest Publications

  • Open Access

    An Optimized Approach for Methane Spectral Feature Extraction Under High-Humidity Conditions

    by Yunze Li, Jun Wu, Wei Xiong, Dacheng Li, Yangyu Li, Anjing Wang, Fangxiao Cui

    Fourier transform infrared (FTIR) spectroscopy-based gas remote sensing has been widely applied for long-range atmospheric composition analysis. However, when deployed for longwave infrared methane detection, spectral features of methane are significantly interfered by water vapor variations at the edge of atmospheric window, which compromises detection performance. To address the spectral fitting degradation caused by relative changes between methane and water vapor signals, this study incorporates temperature, relative humidity, and sensing distance into the cost function, establishing a continuous optimization space with concentration path lengths (CLs) as variables, which are the product of the concentration and path length. A hybrid differential evolution and Levenberg–Marquardt (D-LM) algorithm is developed to enhance parameter estimation accuracy. Combined with a three-layer atmospheric model for real-time reference spectrum generation, the algorithm identifies the optimal spectral combination that provides the best match to the measured data. Algorithm performance is validated through two experimental configurations: Firstly, adaptive detection using synthetic spectra covering various humidity–methane concentration combinations is conducted; simulation results demonstrate that the proposed method significantly reduces the mean squared error (MSE) of fitting residuals by 95.8% compared to the traditional LASSO method, effectively enhancing methane spectral feature extraction under high-water-vapor conditions. Then, a continuous monitoring of controlled methane releases over a 500 m open path under high-outdoor-humidity conditions is carried out to validate outdoor performance of the proposed algorithm; field measurement analysis further confirms the method’s robustness, achieving a reduction in fitting residuals of approximately 57% and improving spectral structure fitting. The proposed approach provides a reliable technical pathway for adaptive gas cloud detection under complex atmospheric conditions.

  • Open Access

    A Two-Stage YOLOv5s–U-Net Framework for Defect Localization and Segmentation in Overhead Transmission Lines

    by Aohua Li, Dacheng Li, Anjing Wang

    Transmission-line defect detection is crucial for grid operation. Existing methods struggle to balance defect localization and fine segmentation. Therefore, this study proposes a novel cascaded two-stage framework that first utilizes YOLOv5s for the global localization of defective regions, and then uses U-Net for the fine segmentation of candidate regions. To improve the segmentation performance, U-Net adopts a transfer learning strategy based on the VGG16 pretrained model to alleviate the impact of limited dataset size on the training effect. Meanwhile, a hybrid loss function that combines Dice Loss and Focal Loss is designed to solve the small-target and class imbalance problems. This method integrates target detection and fine segmentation, enhancing detection precision and improving the extraction of detailed damage features. Experiments on the self-constructed dataset show that the method achieves 87% mAP on YOLOv5s, 88% U-Net damage recognition precision, a mean Dice coefficient of 93.66%, and 89% mIoU, demonstrating its effectiveness in accurately detecting transmission-line defects and efficiently segmenting the damage region, providing assistance for the intelligent operation and maintenance of transmission lines.


  • Open Access

    A Multi-Spectral Thermal Gas Detection Imager Using Uncooled Infrared Camera

    by Fang-Xiao Cui, Yue Zhao, An-Jing Wang, Feng-Xiang Ma, Jun Wu, Yang-Yu Li, Da-Cheng Li, Wang-Chao Dong

    Gas remote detection is useful for early warning of gas leakage and toxic chemicals. Optical gas imaging (OGI) built with an uncooled infrared camera is superior to cooled detectors in terms of cost. Current mainstream OGI technologies fall short in their detection of gases at ambient temperature and their ability to classify multiple gases. A multi-spectral uncooled imager is developed to try to solve these problems, which is constructed from a commercial uncooled thermal camera and wide band filters. To solve filter self-radiation and unevenness, a correction method is devised, with an ambient temperature blackbody placed in front and subtracted from the measured image. Based on waveband cutoffs, filters are classified into target-sensitive filters and background filters. Multi-spectra are simulated according to wide band filter transmittance, which can be used in gas classification. A sulfur hexafluoride (SF6) experiment is conducted outdoors at a distance of 10 m. An SVM model is trained to classify gas release in real time. Detection with a cold sky background is improved with the aid of data cube differences in a time sequence. The SF6 outdoor experiment concluded with preliminary effective results of ambient temperature gas remote detection.