Yangyu Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yangyu Li has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Dacheng Li
Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
3 shared publications - Anjing Wang
Anhui Province Key Laboratory of Optical Quantitative Remote Sensing, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
2 shared publications - Fangxiao Cui
Anhui Province Key Laboratory of Optical Quantitative Remote Sensing, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
2 shared publications - Jun Wu
Anhui Province Key Laboratory of Optical Quantitative Remote Sensing, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
2 shared publications - Wei Xiong
Anhui Province Key Laboratory of Optical Quantitative Remote Sensing, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
2 shared publications - Fengxiang Ma
Electric Power Research Institute of State Grid Anhui Electric Power Company, Ltd., Hefei, China
1 shared publication
Latest Publications
- Open Access
Research on Kinematic Error of Pendulum Interferometer Based on Optomechanical Coupled Simulation
To address the issue of normal displacement deviation induced by the geometric nonlinearity of cross-spring flexural pivots in pendulum-type interferometers, which leads to modulation attenuation, this study proposes a co-simulation method combining Finite Element Analysis (FEA) and Physical Optics. First, an optomechanical model was established based on the retroreflective property of cube-corner prisms and a double-pendulum differential scanning architecture (where the optical path difference is four times the mechanical displacement). Using the ANSYS Workbench 2022 R1 transient dynamics module with the “Large Deflection” algorithm enabled, the nonlinear motion trajectories of single-pivot and dual-pivot flexural hinges were quantitatively compared. Subsequently, a multi-physics data mapping interface was established to map mechanical motion errors into a physical optics simulation model, where the interference modulation was accurately calculated via electromagnetic field tracing. Results demonstrate that under ambient temperature (25 °C) and a spectral resolution of 1 cm−1, the normal displacement deviation of the single-pivot hinge is only 0.00165 mm, representing a 95.6% reduction compared to the dual-pivot structure (0.03765 mm). Furthermore, the modulation of the single-pivot structure remains above 0.98 throughout the scanning range, significantly outperforming the nonlinear decay characteristic of the dual-pivot structure. These findings provide a theoretical basis for the structural optimization and selection of high-precision portable FTIR spectrometers.
Open AccessResearch on Kinematic Error of Pendulum Interferometer Based on Optomechanical Coupled Simulation
To address the issue of normal displacement deviation induced by the geometric nonlinearity of cross-spring flexural pivots in pendulum-type interferometers, which leads to modulation attenuation, this study proposes a co-simulation method combining Finite Element Analysis (FEA) and Physical Optics. First, an optomechanical model was established based on the retroreflective property of cube-corner prisms and a double-pendulum differential scanning architecture (where the optical path difference is four times the mechanical displacement). Using the ANSYS Workbench 2022 R1 transient dynamics module with the “Large Deflection” algorithm enabled, the nonlinear motion trajectories of single-pivot and dual-pivot flexural hinges were quantitatively compared. Subsequently, a multi-physics data mapping interface was established to map mechanical motion errors into a physical optics simulation model, where the interference modulation was accurately calculated via electromagnetic field tracing. Results demonstrate that under ambient temperature (25 °C) and a spectral resolution of 1 cm−1, the normal displacement deviation of the single-pivot hinge is only 0.00165 mm, representing a 95.6% reduction compared to the dual-pivot structure (0.03765 mm). Furthermore, the modulation of the single-pivot structure remains above 0.98 throughout the scanning range, significantly outperforming the nonlinear decay characteristic of the dual-pivot structure. These findings provide a theoretical basis for the structural optimization and selection of high-precision portable FTIR spectrometers.
- Open Access
- 5 January 2026
- Published by MDPI AG in Remote Sensing
- Vol. 18 (1) , 175
An Optimized Approach for Methane Spectral Feature Extraction Under High-Humidity Conditions
Fourier transform infrared (FTIR) spectroscopy-based gas remote sensing has been widely applied for long-range atmospheric composition analysis. However, when deployed for longwave infrared methane detection, spectral features of methane are significantly interfered by water vapor variations at the edge of atmospheric window, which compromises detection performance. To address the spectral fitting degradation caused by relative changes between methane and water vapor signals, this study incorporates temperature, relative humidity, and sensing distance into the cost function, establishing a continuous optimization space with concentration path lengths (CLs) as variables, which are the product of the concentration and path length. A hybrid differential evolution and Levenberg–Marquardt (D-LM) algorithm is developed to enhance parameter estimation accuracy. Combined with a three-layer atmospheric model for real-time reference spectrum generation, the algorithm identifies the optimal spectral combination that provides the best match to the measured data. Algorithm performance is validated through two experimental configurations: Firstly, adaptive detection using synthetic spectra covering various humidity–methane concentration combinations is conducted; simulation results demonstrate that the proposed method significantly reduces the mean squared error (MSE) of fitting residuals by 95.8% compared to the traditional LASSO method, effectively enhancing methane spectral feature extraction under high-water-vapor conditions. Then, a continuous monitoring of controlled methane releases over a 500 m open path under high-outdoor-humidity conditions is carried out to validate outdoor performance of the proposed algorithm; field measurement analysis further confirms the method’s robustness, achieving a reduction in fitting residuals of approximately 57% and improving spectral structure fitting. The proposed approach provides a reliable technical pathway for adaptive gas cloud detection under complex atmospheric conditions.
- 5 January 2026
- Published by MDPI AG in Remote Sensing
- Vol. 18 (1) , 175
Open AccessAn Optimized Approach for Methane Spectral Feature Extraction Under High-Humidity Conditions
Fourier transform infrared (FTIR) spectroscopy-based gas remote sensing has been widely applied for long-range atmospheric composition analysis. However, when deployed for longwave infrared methane detection, spectral features of methane are significantly interfered by water vapor variations at the edge of atmospheric window, which compromises detection performance. To address the spectral fitting degradation caused by relative changes between methane and water vapor signals, this study incorporates temperature, relative humidity, and sensing distance into the cost function, establishing a continuous optimization space with concentration path lengths (CLs) as variables, which are the product of the concentration and path length. A hybrid differential evolution and Levenberg–Marquardt (D-LM) algorithm is developed to enhance parameter estimation accuracy. Combined with a three-layer atmospheric model for real-time reference spectrum generation, the algorithm identifies the optimal spectral combination that provides the best match to the measured data. Algorithm performance is validated through two experimental configurations: Firstly, adaptive detection using synthetic spectra covering various humidity–methane concentration combinations is conducted; simulation results demonstrate that the proposed method significantly reduces the mean squared error (MSE) of fitting residuals by 95.8% compared to the traditional LASSO method, effectively enhancing methane spectral feature extraction under high-water-vapor conditions. Then, a continuous monitoring of controlled methane releases over a 500 m open path under high-outdoor-humidity conditions is carried out to validate outdoor performance of the proposed algorithm; field measurement analysis further confirms the method’s robustness, achieving a reduction in fitting residuals of approximately 57% and improving spectral structure fitting. The proposed approach provides a reliable technical pathway for adaptive gas cloud detection under complex atmospheric conditions.
- Open Access
A Multi-Spectral Thermal Gas Detection Imager Using Uncooled Infrared Camera
Gas remote detection is useful for early warning of gas leakage and toxic chemicals. Optical gas imaging (OGI) built with an uncooled infrared camera is superior to cooled detectors in terms of cost. Current mainstream OGI technologies fall short in their detection of gases at ambient temperature and their ability to classify multiple gases. A multi-spectral uncooled imager is developed to try to solve these problems, which is constructed from a commercial uncooled thermal camera and wide band filters. To solve filter self-radiation and unevenness, a correction method is devised, with an ambient temperature blackbody placed in front and subtracted from the measured image. Based on waveband cutoffs, filters are classified into target-sensitive filters and background filters. Multi-spectra are simulated according to wide band filter transmittance, which can be used in gas classification. A sulfur hexafluoride (SF6) experiment is conducted outdoors at a distance of 10 m. An SVM model is trained to classify gas release in real time. Detection with a cold sky background is improved with the aid of data cube differences in a time sequence. The SF6 outdoor experiment concluded with preliminary effective results of ambient temperature gas remote detection.
Open AccessA Multi-Spectral Thermal Gas Detection Imager Using Uncooled Infrared Camera
Gas remote detection is useful for early warning of gas leakage and toxic chemicals. Optical gas imaging (OGI) built with an uncooled infrared camera is superior to cooled detectors in terms of cost. Current mainstream OGI technologies fall short in their detection of gases at ambient temperature and their ability to classify multiple gases. A multi-spectral uncooled imager is developed to try to solve these problems, which is constructed from a commercial uncooled thermal camera and wide band filters. To solve filter self-radiation and unevenness, a correction method is devised, with an ambient temperature blackbody placed in front and subtracted from the measured image. Based on waveband cutoffs, filters are classified into target-sensitive filters and background filters. Multi-spectra are simulated according to wide band filter transmittance, which can be used in gas classification. A sulfur hexafluoride (SF6) experiment is conducted outdoors at a distance of 10 m. An SVM model is trained to classify gas release in real time. Detection with a cold sky background is improved with the aid of data cube differences in a time sequence. The SF6 outdoor experiment concluded with preliminary effective results of ambient temperature gas remote detection.