WDWangchao Dong

Wangchao Dong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wangchao Dong has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Voltage Stability Mechanism of Grid-Connected Permanent Magnet Synchronous Generator Under Large Grid-Side Disturbances

    by Xun Mao, Wangchao Dong, Kai Lyv, Wei Tang, Zhen Wang, Li Guo, Yong Zhan, Yang Pu

    As a mainstream new energy generation technology, elucidating the grid-connected voltage stability mechanisms of permanent magnet synchronous generator (PMSG) is critical for ensuring stable integration of high-penetration renewable energy. Existing research on the voltage stability of grid-connected PMSG systems is confined to single-fault scenarios, failing to adequately account for the impacts of other significant internal grid disturbances, such as direct current blockings and increased renewable energy penetration. Moreover, the traditionally used simplified grid model with a voltage source in series with an impedance is overly idealized, making it difficult to comprehensively reveal the transient stability mechanisms of grid-connected PMSG systems under complex multi-disturbance conditions. To address this issue, this paper proposes a numerical analysis method to investigate the grid stability mechanisms of PMSG systems under various grid disturbance scenarios. First, an electromagnetic transient simulation model of the grid-connected PMSG system is established. Next, key parameters influencing the system’s voltage stability are identified using the global sensitivity Sobol method. Subsequently, a transient voltage stability assessment index and a method for revealing the grid stability patterns of PMSG systems are presented. Finally, the PMSG system is integrated into the CSEE standard test system on the CloudPSS platform for validation and analysis. The results demonstrate that the proposed method effectively reveals voltage stability mechanisms considering various internal grid disturbances, and the mechanistic characteristics it reveals differ significantly from conclusions drawn using a simplified grid model.

  • Open Access

    Understanding of Power Oscillation Mechanism Analysis with Fluctuation Propagation in Grid-Forming Converter

    by Kai Lv, Xun Mao, Wangchao Dong, Zhen Wang

    This work proposes a generic model for clarifying the mechanism hidden in the phenomena of fluctuation propagation in grid-forming (GF-VSG) systems, considering the impact of different disturbances. Additionally, a new judgment criterion is established to give physical insights into the power oscillation stability of the GFMC system. And this judgment criterion, as well as the model, can identify the power stability combined with fluctuation propagation phenomenon no matter what the disturbance is, which can also give guidance to the controller design to guarantee that the GFMC can operate in normal operation conditions while leisurely confronting various disturbances. In addition, it is found that the established conventional single closed-loop system may lose effectiveness in judging stability, especially when the oscillation propagation of disturbance occurs. Finally, the proposed model and judgment criteria are demonstrated by experiments.

  • Open Access

    Aggregation of Air Conditioning Loads in Building Microgrids: A Day-Ahead and Real-Time Control Strategy Considering User Privacy Requirements

    by Jinjin Ding, Wangchao Dong, Bin Xu, Dan Hu, Zheng Tian, Donglin Qin, Hongbin Wu

    Air conditioning loads play a critical role in maintaining the supply–demand balance of building microgrids (BMGs), yet their distributed nature and volatile response may undermine secure and stable operation. This paper proposes a day-ahead and real-time aggregated control strategy for BMG air conditioning loads with user privacy protection. First, an approximate aggregation model is developed based on building heat transfer characteristics, and the aggregated response potential is evaluated by jointly considering user comfort and willingness. Second, without sharing fine-grained user information, a Building Microgrid Operator (BMO)–Load Aggregator (LA) day-ahead distributed-scheduling model is formulated and solved using the alternating direction method of multipliers (ADMM). Finally, to address load fluctuations caused by heterogeneous initial indoor temperature distributions, a real-time control strategy based on State-Queueing (SQ) temperature-state pre-transfer is proposed. Case studies show that, compared with the baseline scheme, the proposed method reduces the system operating cost from CNY 50,694.58 to CNY 47,131.64, a 7% decrease, and decreases load shedding from 1466.35 kWh to 257.31 kWh, an 82% decrease. Meanwhile, the real-time control effectively suppresses power fluctuations in the early control stage, thereby improving both economic performance and response smoothness.


  • Research on Evaluation Methods for the DC Carrying Capacity of New Energy DC Transmission Systems

    by Siyou Bai, Xun Mao, Wangchao Dong, Chaobing Xu, Fei Liao, Peng Xiaotao

  • Open Access

    Introduction to Domestic and International Sulfur Hexafluoride (SF6) Greenhouse Gas Emission Reduction Technologies for Power Grid Enterprises

    by Wangchao Dong, Yue Zhao, Fengxiang Ma, Feng Zhu, Wei Liu, Yumei Song, Shan Zhu, Han Chen

    Since its introduction in 1930, sulfur hexafluoride (SF6) has rapidly become the primary insulation material for high-voltage electrical equipment such as transmission lines, switches, transformers, circuit breakers, and reactors, owing to its exceptional electrical properties. However, the flip side of its excellent performance is its extremely high global warming potential (GWP), which is over 23,000 times that of carbon dioxide (CO2). Managing SF6 has thus become a key aspect of emission reduction efforts. The primary strategies for reducing SF6 emissions include minimizing gas leakage during the production, operation, and maintenance of electrical equipment, as well as purifying and recycling emitted SF6 gas. Various purification and monitoring methods have been developed for routine operations and have already been implemented by power grid companies globally. In addition to ongoing daily monitoring, research is also underway concerning the transformation, degradation, and substitution of SF6 gases. Degradation and transformation methods primarily focus on high-temperature degradation, photocatalysis, and arc degradation. In the context of substitution, the idea is to use conventional gases or various organic compounds to form SF6 mixtures or alternative gases, with the aim of reducing effect of leakage while maintaining performance. Finally, recommendations are made for power grid enterprises to reduce SF6 emissions, emphasizing the importance of source control and the exploration of alternatives. Effective equipment management to prevent gas leakage, comprehensive monitoring and assessment, as well as the proper handling of unusable SF6 devices, are also crucial steps in emission reduction efforts.


  • Open Access

    A Multi-Spectral Thermal Gas Detection Imager Using Uncooled Infrared Camera

    by Fang-Xiao Cui, Yue Zhao, An-Jing Wang, Feng-Xiang Ma, Jun Wu, Yang-Yu Li, Da-Cheng Li, Wang-Chao Dong

    Gas remote detection is useful for early warning of gas leakage and toxic chemicals. Optical gas imaging (OGI) built with an uncooled infrared camera is superior to cooled detectors in terms of cost. Current mainstream OGI technologies fall short in their detection of gases at ambient temperature and their ability to classify multiple gases. A multi-spectral uncooled imager is developed to try to solve these problems, which is constructed from a commercial uncooled thermal camera and wide band filters. To solve filter self-radiation and unevenness, a correction method is devised, with an ambient temperature blackbody placed in front and subtracted from the measured image. Based on waveband cutoffs, filters are classified into target-sensitive filters and background filters. Multi-spectra are simulated according to wide band filter transmittance, which can be used in gas classification. A sulfur hexafluoride (SF6) experiment is conducted outdoors at a distance of 10 m. An SVM model is trained to classify gas release in real time. Detection with a cold sky background is improved with the aid of data cube differences in a time sequence. The SF6 outdoor experiment concluded with preliminary effective results of ambient temperature gas remote detection.