Jacob A. Gottfried
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jacob A. Gottfried has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Azer P. Yalin
Mechanical Engineering, Colorado State University, Fort Collins, USA
3 shared publications Charles E. Rose
Sandia National Laboratory 2 , Albuquerque, New Mexico 87123, USA
1 shared publicationChen Shen
University of Wisconsin-Madison
1 shared publicationDane Morgan
University of Wisconsin-Madison
1 shared publicationMalcolm Roux
Colorado State University
1 shared publicationMark H. Anderson
University of Wisconsin-Madison
1 shared publication
Latest Publications
- 17 April 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (8) , 15812-15821
Demonstration of partially transparent thick metallic sodium in the vacuum ultraviolet spectral range: comment
In a previous publication [ Opt. Express 21 , 28182 ( 2013 ) 10.1364/OE.21.028182 ], Daido et al . reported that solid samples of metallic sodium exhibited high transparency of vacuum ultraviolet light through several millimeter-thick samples. The calculated extinction coefficient associated with these observations was near 7E-7, over 4 orders of magnitude lower than previous measurements. In this paper, we will compare the phenomenon reported by Daido et al . with the existing literature to establish that there is no peer-reviewed support for the observations. Further, this paper will discuss a rigorous experimental campaign that failed to replicate the transmission phenomenon observed by Daido et al .
- 17 April 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (8) , 15812-15821
Demonstration of partially transparent thick metallic sodium in the vacuum ultraviolet spectral range: comment
In a previous publication [ Opt. Express 21 , 28182 ( 2013 ) 10.1364/OE.21.028182 ], Daido et al . reported that solid samples of metallic sodium exhibited high transparency of vacuum ultraviolet light through several millimeter-thick samples. The calculated extinction coefficient associated with these observations was near 7E-7, over 4 orders of magnitude lower than previous measurements. In this paper, we will compare the phenomenon reported by Daido et al . with the existing literature to establish that there is no peer-reviewed support for the observations. Further, this paper will discuss a rigorous experimental campaign that failed to replicate the transmission phenomenon observed by Daido et al .
- 18 December 2023
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (1) , 9-21
Krypton tagging velocimetry in the plume of a plasma hollow cathode
Krypton tagging velocimetry (KTV) is an emerging flow diagnostic that investigates the bulk movement of high-speed, low-pressure gas flows. The present contribution expands the typical KTV method to the lower density (vacuum) conditions of interest in electric propulsion research. Our KTV scheme utilizes a two-photon (Write) excitation at 214.7 nm from a pulsed dye laser, followed by (Read) re-excitation of the ensuing metastable at 769.5 nm with an optical parametric oscillator. For the case of cold krypton gas expanding from a hollow cathode into vacuum, we find a bulk velocity of 452 ± 37 m/s and temperature of 20 ± 16 K. We also study the flow in the plume with the hollow cathode plasma operating for which we find bulk velocity of 1200 ± 130 m/s and temperature of 880 ± 370 K. Measurements are performed at background pressures down to ∼10−5 Torr.
- 18 December 2023
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (1) , 9-21
Krypton tagging velocimetry in the plume of a plasma hollow cathode
Krypton tagging velocimetry (KTV) is an emerging flow diagnostic that investigates the bulk movement of high-speed, low-pressure gas flows. The present contribution expands the typical KTV method to the lower density (vacuum) conditions of interest in electric propulsion research. Our KTV scheme utilizes a two-photon (Write) excitation at 214.7 nm from a pulsed dye laser, followed by (Read) re-excitation of the ensuing metastable at 769.5 nm with an optical parametric oscillator. For the case of cold krypton gas expanding from a hollow cathode into vacuum, we find a bulk velocity of 452 ± 37 m/s and temperature of 20 ± 16 K. We also study the flow in the plume with the hollow cathode plasma operating for which we find bulk velocity of 1200 ± 130 m/s and temperature of 880 ± 370 K. Measurements are performed at background pressures down to ∼10−5 Torr.
- Open Access
- 12 December 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 121 (24)
Collective Thomson scattering measurement of plasma evolution during the current pulse in a laser-triggered switch
High-voltage laser-triggered switches (HV-LTSs) are used in pulsed-power applications where low jitter and precise timing are required. The switches allow operation in the megaampere, megavolt regime while maintaining low insertion losses. Currently, there is a lack of detailed plasma measurements in these switches, yet such measurements are needed to elucidate the detailed physics, which include a range of processes such as laser breakdown, streamer formation and growth, current flow, plasma evolution, and cooling. Detailed spatially- and temporally resolved measurements of plasma properties within the switches could contribute to validating and advancing numeric models of these systems. This contribution presents laser Thomson scattering measurements of the electron number density and temperature evolution in a HV-LTS. The switch was operated at 6 kV with current flow for a duration of 145 ns and a peak current density of 0.2 MA/cm2 into a matched load. The Thomson scattering diagnostic system uses a 532 nm probe from an Nd:YAG laser allowing a temporal resolution of ∼10 ns. We find that during the switch current pulse, the plasma electron temperature rose from a starting value of 8.1 ± 1.6 eV (due to cooling of the earlier trigger laser plasma) to a peak value of 26 ± 5 eV with an associated increase in the electron density from 8.6 ± 1.7 × 1017 to 3.1 ± 0.6 × 1018 cm−3.
- 12 December 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 121 (24)
Open AccessCollective Thomson scattering measurement of plasma evolution during the current pulse in a laser-triggered switch
High-voltage laser-triggered switches (HV-LTSs) are used in pulsed-power applications where low jitter and precise timing are required. The switches allow operation in the megaampere, megavolt regime while maintaining low insertion losses. Currently, there is a lack of detailed plasma measurements in these switches, yet such measurements are needed to elucidate the detailed physics, which include a range of processes such as laser breakdown, streamer formation and growth, current flow, plasma evolution, and cooling. Detailed spatially- and temporally resolved measurements of plasma properties within the switches could contribute to validating and advancing numeric models of these systems. This contribution presents laser Thomson scattering measurements of the electron number density and temperature evolution in a HV-LTS. The switch was operated at 6 kV with current flow for a duration of 145 ns and a peak current density of 0.2 MA/cm2 into a matched load. The Thomson scattering diagnostic system uses a 532 nm probe from an Nd:YAG laser allowing a temporal resolution of ∼10 ns. We find that during the switch current pulse, the plasma electron temperature rose from a starting value of 8.1 ± 1.6 eV (due to cooling of the earlier trigger laser plasma) to a peak value of 26 ± 5 eV with an associated increase in the electron density from 8.6 ± 1.7 × 1017 to 3.1 ± 0.6 × 1018 cm−3.
- 20 June 2022
- Published by American Institute of Aeronautics and Astronautics (AIAA)
Electron Density and Temperature Measurements by Thomson Scattering in a High-Voltage Laser-Triggered Switch
View Video Presentation: https://doi.org/10.2514/6.2022-3496.vid High-voltage laser-triggered switches (HV-LTS) can deliver kiloampere magnitude currents in nanosecond time frames while having a jitter on the order of only picoseconds to nanoseconds. The most popular model used to simulate the behavior of HV-LTS is the Martin Switch model. However, recent designs of HV-LTS have found inconsistencies in the Martin Switch model that prohibit modeling switches designed to have on-times of hundreds of nanoseconds. The suspected reason for these inconsistencies is the assumptions T. H. Martin used in his derivation, specifically, that the plasma conductivity is constant both spatially and temporally. This study investigates the behavior of plasma conductivity via temporally and spatially-resolved measurements of electron temperature and density by Laser Thomson scattering. We find that the plasma conductivity does have a spatial and temporal dependency during the decay of the plasma channel. Further improvements to the diagnostic setup are necessary to allow earlier time measurements during the switch discharge phase to inform the Martin Model.
- 20 June 2022
- Published by American Institute of Aeronautics and Astronautics (AIAA)
Electron Density and Temperature Measurements by Thomson Scattering in a High-Voltage Laser-Triggered Switch
View Video Presentation: https://doi.org/10.2514/6.2022-3496.vid High-voltage laser-triggered switches (HV-LTS) can deliver kiloampere magnitude currents in nanosecond time frames while having a jitter on the order of only picoseconds to nanoseconds. The most popular model used to simulate the behavior of HV-LTS is the Martin Switch model. However, recent designs of HV-LTS have found inconsistencies in the Martin Switch model that prohibit modeling switches designed to have on-times of hundreds of nanoseconds. The suspected reason for these inconsistencies is the assumptions T. H. Martin used in his derivation, specifically, that the plasma conductivity is constant both spatially and temporally. This study investigates the behavior of plasma conductivity via temporally and spatially-resolved measurements of electron temperature and density by Laser Thomson scattering. We find that the plasma conductivity does have a spatial and temporal dependency during the decay of the plasma channel. Further improvements to the diagnostic setup are necessary to allow earlier time measurements during the switch discharge phase to inform the Martin Model.