Azer P. Yalin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Azer P. Yalin has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Jacob A. Gottfried
University of Wisconsin-Madison
3 shared publications - John D. Williams
Colorado State University 4 Department of Mechanical Engineering Fort Collins, Colorado 80523
3 shared publications Lei Tao
Department of Mechanical Engineering Colorado State University Fort Collin 80523 CO USA
3 shared publications- Anthony DeMario
Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
2 shared publications - Christian L'ORange
Colorado State University
2 shared publications - Ciprian Dumitrache
Colorado State University
2 shared publications
Latest Publications
- Open Access
- 9 July 2026
- Published by Elsevier in SSRN Electronic Journal
Origin of Prompt Optical Emission of Femtosecond Laser Filaments in Nitrogen at Different Pressures
Despite extensive research efforts, the early-time behavior of femtosecond (fs) filaments remains poorly understood. The complex interplay of nonlinear optical phenomena makes fs filaments inherently challenging to characterize, particularly the population dynamics of excited species within the first few nanoseconds. This work investigates the early-time behavior of femtosecond filaments in nitrogen by examining the respective roles of photoionization, dipole coupling between ionic levels, and post-pulse plasma kinetics. The system is modeled by coupling a time-dependent Schrödinger equation treatment of the N2+ nuclear wave function, which captures fs-scale quantum dynamics, with a nonequilibrium plasma kinetic model to resolve the post-pulse plasma dynamics. The modeled excited-state populations are compared directly with time-resolved optical emission spectroscopy measurements, allowing the dominant pathways responsible for the observed N2+ (B–X) and N2(C–B) emission to be identified. The results show that the majority of the N2+(B) emission originates from strong-field ionization and dipole coupling during the femtosecond pulse rather than from post-pulse electron-impact ionization. In contrast, the persistence of N2(C) emission is strongly influenced by pressure-dependent post-pulse kinetics, including ion clustering, recombination, and energypooling pathways. The results reveal that plasma composition and spectral characteristics vary significantly with pressure, as distinct pathways for production and loss of excited species become dominant. These insights advance the understanding of early-time plasma formation and emission in femtosecond nitrogen filaments, with direct relevance to fs-LIBS, directed-energy systems, plasma-assisted combustion, biomedical applications, and Femtosecond Laser Electronic Excitation Tagging (FLEET).
- 9 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOrigin of Prompt Optical Emission of Femtosecond Laser Filaments in Nitrogen at Different Pressures
Despite extensive research efforts, the early-time behavior of femtosecond (fs) filaments remains poorly understood. The complex interplay of nonlinear optical phenomena makes fs filaments inherently challenging to characterize, particularly the population dynamics of excited species within the first few nanoseconds. This work investigates the early-time behavior of femtosecond filaments in nitrogen by examining the respective roles of photoionization, dipole coupling between ionic levels, and post-pulse plasma kinetics. The system is modeled by coupling a time-dependent Schrödinger equation treatment of the N2+ nuclear wave function, which captures fs-scale quantum dynamics, with a nonequilibrium plasma kinetic model to resolve the post-pulse plasma dynamics. The modeled excited-state populations are compared directly with time-resolved optical emission spectroscopy measurements, allowing the dominant pathways responsible for the observed N2+ (B–X) and N2(C–B) emission to be identified. The results show that the majority of the N2+(B) emission originates from strong-field ionization and dipole coupling during the femtosecond pulse rather than from post-pulse electron-impact ionization. In contrast, the persistence of N2(C) emission is strongly influenced by pressure-dependent post-pulse kinetics, including ion clustering, recombination, and energypooling pathways. The results reveal that plasma composition and spectral characteristics vary significantly with pressure, as distinct pathways for production and loss of excited species become dominant. These insights advance the understanding of early-time plasma formation and emission in femtosecond nitrogen filaments, with direct relevance to fs-LIBS, directed-energy systems, plasma-assisted combustion, biomedical applications, and Femtosecond Laser Electronic Excitation Tagging (FLEET).
- Open Access
- 3 June 2026
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 5 (1) , 24
LIF measurements of $\mathrm{N}_2^+$ IVDF for molecular and air breathing electric propulsionLaser-induced fluorescence (LIF) diagnostics for molecular ions remain far less developed than their noble gas counterparts, despite growing interest in molecular propellants for electric propulsion (EP). In this work, a LIF diagnostic targeting the $$\mathrm{N}_2^{+}\,(B^2\Sigma_u^+ - X^2\Sigma_g^+)$$ First Negative System is developed and applied to an EP relevant plasma discharge. A practical excitation–fluorescence scheme is defined, supported by a spectral model to analyze absorption and fluorescence processes and to guide excitation-line selection. The LIF diagnostic is applied to the plume of a hidden anode plasma, operating on nitrogen feed gas, enabling spatially resolved measurements of ion velocity distribution functions (IVDFs). The IVDFs obtained reveal distributed ionization and acceleration, with fast ions appearing several millimeters downstream of the source, consistent with probe measurements. These results represent the first application of LIF for IVDFs of molecular ions in EP relevant systems. Finally, a comparative analysis of LIF signal-levels between molecular and atomic (noble gas) ions, including consideration of linestrengths and population fractions, is presented.- 3 June 2026
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 5 (1) , 24
Open AccessLIF measurements of $\mathrm{N}_2^+$ IVDF for molecular and air breathing electric propulsionLaser-induced fluorescence (LIF) diagnostics for molecular ions remain far less developed than their noble gas counterparts, despite growing interest in molecular propellants for electric propulsion (EP). In this work, a LIF diagnostic targeting the $$\mathrm{N}_2^{+}\,(B^2\Sigma_u^+ - X^2\Sigma_g^+)$$ First Negative System is developed and applied to an EP relevant plasma discharge. A practical excitation–fluorescence scheme is defined, supported by a spectral model to analyze absorption and fluorescence processes and to guide excitation-line selection. The LIF diagnostic is applied to the plume of a hidden anode plasma, operating on nitrogen feed gas, enabling spatially resolved measurements of ion velocity distribution functions (IVDFs). The IVDFs obtained reveal distributed ionization and acceleration, with fast ions appearing several millimeters downstream of the source, consistent with probe measurements. These results represent the first application of LIF for IVDFs of molecular ions in EP relevant systems. Finally, a comparative analysis of LIF signal-levels between molecular and atomic (noble gas) ions, including consideration of linestrengths and population fractions, is presented. - Open Access
- 8 April 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (14)
2D krypton density maps in a SPT-70 Hall effect thruster by two-photon absorption laser induced fluorescence (TALIF)
There is a growing recognition of the importance of neutral density fields to the physics, and particularly facility related effects, of Hall-effect thrusters (HETs). This work presents the first high-resolution (mm scale) spatial maps of neutral density in the near-field plume of a HET using two-photon absorption laser-induced fluorescence (TALIF). We employ a 212.6 nm TALIF excitation scheme, based on a pulsed nanosecond dye laser, to map absolute krypton neutral densities in the plume of a SPT-70 HET. Absolute densities are determined via a ratio-based approach using cold-flow measurements. The diagnostic system incorporates active wavelength stabilization via a feedback-controlled dye laser with drift correction algorithms to maintain measurement accuracy through extended mapping campaigns. Neutral density maps are acquired under cold-flow conditions and four plasma-operating states (540 and 720 W at varying background pressures), highlighting the effects of power level and background pressure on the near-field neutral particle profile. These results provide important experimental benchmarks for validating computational models and advancing physical understanding of neutral behavior and electric propulsion facility effects.
- 8 April 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (14)
Open Access2D krypton density maps in a SPT-70 Hall effect thruster by two-photon absorption laser induced fluorescence (TALIF)
There is a growing recognition of the importance of neutral density fields to the physics, and particularly facility related effects, of Hall-effect thrusters (HETs). This work presents the first high-resolution (mm scale) spatial maps of neutral density in the near-field plume of a HET using two-photon absorption laser-induced fluorescence (TALIF). We employ a 212.6 nm TALIF excitation scheme, based on a pulsed nanosecond dye laser, to map absolute krypton neutral densities in the plume of a SPT-70 HET. Absolute densities are determined via a ratio-based approach using cold-flow measurements. The diagnostic system incorporates active wavelength stabilization via a feedback-controlled dye laser with drift correction algorithms to maintain measurement accuracy through extended mapping campaigns. Neutral density maps are acquired under cold-flow conditions and four plasma-operating states (540 and 720 W at varying background pressures), highlighting the effects of power level and background pressure on the near-field neutral particle profile. These results provide important experimental benchmarks for validating computational models and advancing physical understanding of neutral behavior and electric propulsion facility effects.
- Open Access
Laser-Induced Breakdown Spectroscopy and Shadowgraphy of Acoustically Levitated Heptane Droplets
In this study, we examined the impact of droplet size and laser energy on droplet fragmentation and the resulting species composition due to laser irradiation of an acoustically levitated heptane droplet. Using shadowgraphy and spatially resolved laser-induced breakdown spectroscopy (LIBS), we observed two different fragmentation regimes for the conditions studied. The experiments demonstrated that low laser energy densities (<~70 mJ/mm3), designated as regime 1, resulted in a single plasma breakdown event accompanied by broadband emission and C2 Swan bands, suggesting weak plasma formation. Conversely, high energy densities (>~70 mJ/mm3), designated as regime 2, resulted in multiple plasma breakdowns that resulted in the emission of Hα, O, and N, implying a full laser breakdown in the gaseous reactive mixture. Additionally, in regime 2, we calculated the electron density using Stark broadening of the Hα line and temperature using Boltzmann analysis of O lines at 715 nm and 777 nm. We found that the electron densities and temperatures within the air spark and heptane droplets are quite similar. The findings from this research could impact the design of spray ignition systems and may also aid in validating the modeling efforts of aerosols, droplet breakdown, and ignition.
Open AccessLaser-Induced Breakdown Spectroscopy and Shadowgraphy of Acoustically Levitated Heptane Droplets
In this study, we examined the impact of droplet size and laser energy on droplet fragmentation and the resulting species composition due to laser irradiation of an acoustically levitated heptane droplet. Using shadowgraphy and spatially resolved laser-induced breakdown spectroscopy (LIBS), we observed two different fragmentation regimes for the conditions studied. The experiments demonstrated that low laser energy densities (<~70 mJ/mm3), designated as regime 1, resulted in a single plasma breakdown event accompanied by broadband emission and C2 Swan bands, suggesting weak plasma formation. Conversely, high energy densities (>~70 mJ/mm3), designated as regime 2, resulted in multiple plasma breakdowns that resulted in the emission of Hα, O, and N, implying a full laser breakdown in the gaseous reactive mixture. Additionally, in regime 2, we calculated the electron density using Stark broadening of the Hα line and temperature using Boltzmann analysis of O lines at 715 nm and 777 nm. We found that the electron densities and temperatures within the air spark and heptane droplets are quite similar. The findings from this research could impact the design of spray ignition systems and may also aid in validating the modeling efforts of aerosols, droplet breakdown, and ignition.
- Open Access
Open-Path Cavity Ring-Down Spectroscopy for Simultaneous Detection of Hydrogen Chloride and Particles in Cleanroom Environment
The present study addresses advanced monitoring techniques for particles and airborne molecular contaminants (AMCs) in cleanroom environments, which are crucial for ensuring the integrity of semiconductor manufacturing processes. We focus on quantifying particle levels and a representative AMC, hydrogen chloride (HCl), having known detrimental effects on equipment longevity, product yield, and human health. We have developed a compact laser sensor based on open-path cavity ring-down spectroscopy (CRDS) using a 1742 nm near-infrared diode laser source. The sensor enables the high-sensitivity detection of HCl through absorption by the 2-0 vibrational band with an Allan deviation of 0.15 parts per billion (ppb) over 15 min. For quantifying particle number concentrations, we examine various detection methods based on statistical analyses of Mie scattering-induced ring-down time fluctuations. We find that the ring-down distributions’ 3rd and 4th standard moments allow particle detection at densities as low as ~105 m−3 (diameter > 1 μm). These findings provide a basis for the future development of compact cleanroom monitoring instrumentation for wafer-level monitoring for both AMC and particles, including mobile platforms.
Open AccessOpen-Path Cavity Ring-Down Spectroscopy for Simultaneous Detection of Hydrogen Chloride and Particles in Cleanroom Environment
The present study addresses advanced monitoring techniques for particles and airborne molecular contaminants (AMCs) in cleanroom environments, which are crucial for ensuring the integrity of semiconductor manufacturing processes. We focus on quantifying particle levels and a representative AMC, hydrogen chloride (HCl), having known detrimental effects on equipment longevity, product yield, and human health. We have developed a compact laser sensor based on open-path cavity ring-down spectroscopy (CRDS) using a 1742 nm near-infrared diode laser source. The sensor enables the high-sensitivity detection of HCl through absorption by the 2-0 vibrational band with an Allan deviation of 0.15 parts per billion (ppb) over 15 min. For quantifying particle number concentrations, we examine various detection methods based on statistical analyses of Mie scattering-induced ring-down time fluctuations. We find that the ring-down distributions’ 3rd and 4th standard moments allow particle detection at densities as low as ~105 m−3 (diameter > 1 μm). These findings provide a basis for the future development of compact cleanroom monitoring instrumentation for wafer-level monitoring for both AMC and particles, including mobile platforms.
- Open Access
- 13 May 2024
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 3 (1) , 1-13
Temporally resolved relative krypton neutral density during breathing mode of a hall effect thruster recorded by TALIF
A key issue in the development of theory and models for plasma propulsion devices is to describe the instabilities and fluctuations of the devices. It has been widely recognized that many Hall effect thrusters (HETs) exhibit oscillations at frequencies in the range of ∼ 20 kHz. These ionization-related oscillations are generally referred to as Breathing Mode oscillations and have been the subject of considerable research. Here, for the first time, we report direct temporally resolved measurements of the ground state neutral density variation during the period of the oscillation. We used the laser-based Two-Photon Absorption Laser Induced Fluorescence (TALIF) technique to measure neutrals within the plume of a 1.5 kW HET operating on krypton (Kr). Our TALIF scheme employs a frequency-doubled, pulsed dye laser operating at ∼ 212 nm to probe ground state Kr atoms. A novel phase-binning approach is used to recover the time-dependent signal by assigning the timing of each collected TALIF signal (laser shot) relative to the phase of the discharge current. We find that the neutral density fluctuates quite strongly over the period of the oscillation, and that this fluctuation leads the current fluctuation as expected.
- 13 May 2024
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 3 (1) , 1-13
Open AccessTemporally resolved relative krypton neutral density during breathing mode of a hall effect thruster recorded by TALIF
A key issue in the development of theory and models for plasma propulsion devices is to describe the instabilities and fluctuations of the devices. It has been widely recognized that many Hall effect thrusters (HETs) exhibit oscillations at frequencies in the range of ∼ 20 kHz. These ionization-related oscillations are generally referred to as Breathing Mode oscillations and have been the subject of considerable research. Here, for the first time, we report direct temporally resolved measurements of the ground state neutral density variation during the period of the oscillation. We used the laser-based Two-Photon Absorption Laser Induced Fluorescence (TALIF) technique to measure neutrals within the plume of a 1.5 kW HET operating on krypton (Kr). Our TALIF scheme employs a frequency-doubled, pulsed dye laser operating at ∼ 212 nm to probe ground state Kr atoms. A novel phase-binning approach is used to recover the time-dependent signal by assigning the timing of each collected TALIF signal (laser shot) relative to the phase of the discharge current. We find that the neutral density fluctuates quite strongly over the period of the oscillation, and that this fluctuation leads the current fluctuation as expected.
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Portable Thomson scattering system for temporally resolved plasma measurements under low density conditions
We present the development of a portable Thomson scattering diagnostic system allowing simultaneous spatially and temporally resolved plasma property measurements for low density plasmas. The setup uses a compact pulsed Nd:YAG laser (532 nm) as the light source with suppression by two volume Bragg grating notch filters and dispersion with a single-stage spectrometer before measurement with an intensified camera. A key issue is the detailed light collection and how it impacts the sensitivity and elastic light suppression, for which we have investigated two optical configurations, one based on a 7 × 1 linear fiber bundle and the other based on a slit spatial-filter. We find that the configuration with the slit spatial-filter provides a higher sensitivity by a factor of ∼2 along with more uniform spatial response. We have developed a custom pulsed-plasma setup with a modulation at 20 kHz, representative of the Hall thruster breathing mode oscillation, to show the possibility of temporally resolved measurements for electric propulsion applications. We have successfully recorded the variations in electron number density and temperature with sub-mm spatial resolution and capturing ten temporal points over the 50 µs modulation period. The detection limit of electron density (with the spatial-filter configuration) is ∼1.6 × 1017 m−3, which is ∼1/10 of the plasma density in the acceleration channel of Hall thrusters.
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Portable Thomson scattering system for temporally resolved plasma measurements under low density conditions
We present the development of a portable Thomson scattering diagnostic system allowing simultaneous spatially and temporally resolved plasma property measurements for low density plasmas. The setup uses a compact pulsed Nd:YAG laser (532 nm) as the light source with suppression by two volume Bragg grating notch filters and dispersion with a single-stage spectrometer before measurement with an intensified camera. A key issue is the detailed light collection and how it impacts the sensitivity and elastic light suppression, for which we have investigated two optical configurations, one based on a 7 × 1 linear fiber bundle and the other based on a slit spatial-filter. We find that the configuration with the slit spatial-filter provides a higher sensitivity by a factor of ∼2 along with more uniform spatial response. We have developed a custom pulsed-plasma setup with a modulation at 20 kHz, representative of the Hall thruster breathing mode oscillation, to show the possibility of temporally resolved measurements for electric propulsion applications. We have successfully recorded the variations in electron number density and temperature with sub-mm spatial resolution and capturing ten temporal points over the 50 µs modulation period. The detection limit of electron density (with the spatial-filter configuration) is ∼1.6 × 1017 m−3, which is ∼1/10 of the plasma density in the acceleration channel of Hall thrusters.
- 18 December 2023
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (1) , 9-21
Krypton tagging velocimetry in the plume of a plasma hollow cathode
Krypton tagging velocimetry (KTV) is an emerging flow diagnostic that investigates the bulk movement of high-speed, low-pressure gas flows. The present contribution expands the typical KTV method to the lower density (vacuum) conditions of interest in electric propulsion research. Our KTV scheme utilizes a two-photon (Write) excitation at 214.7 nm from a pulsed dye laser, followed by (Read) re-excitation of the ensuing metastable at 769.5 nm with an optical parametric oscillator. For the case of cold krypton gas expanding from a hollow cathode into vacuum, we find a bulk velocity of 452 ± 37 m/s and temperature of 20 ± 16 K. We also study the flow in the plume with the hollow cathode plasma operating for which we find bulk velocity of 1200 ± 130 m/s and temperature of 880 ± 370 K. Measurements are performed at background pressures down to ∼10−5 Torr.
- 18 December 2023
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (1) , 9-21
Krypton tagging velocimetry in the plume of a plasma hollow cathode
Krypton tagging velocimetry (KTV) is an emerging flow diagnostic that investigates the bulk movement of high-speed, low-pressure gas flows. The present contribution expands the typical KTV method to the lower density (vacuum) conditions of interest in electric propulsion research. Our KTV scheme utilizes a two-photon (Write) excitation at 214.7 nm from a pulsed dye laser, followed by (Read) re-excitation of the ensuing metastable at 769.5 nm with an optical parametric oscillator. For the case of cold krypton gas expanding from a hollow cathode into vacuum, we find a bulk velocity of 452 ± 37 m/s and temperature of 20 ± 16 K. We also study the flow in the plume with the hollow cathode plasma operating for which we find bulk velocity of 1200 ± 130 m/s and temperature of 880 ± 370 K. Measurements are performed at background pressures down to ∼10−5 Torr.
- Open Access
Open-Path Laser Absorption Sensor for Mobile Measurements of Atmospheric Ammonia
Anthropogenic emissions of ammonia to the atmosphere, particularly those from agricultural sources, can be damaging to the environment and human health and can drive a need for sensor technologies that can be used to detect and quantify the emissions. Mobile sensing approaches that can be deployed on ground-based or aerial vehicles can provide scalable solutions for high throughput measurements but require relatively compact and low-power sensor systems. This contribution presents an ammonia sensor based on wavelength modulation spectroscopy (WMS) integrated with a Herriott multi-pass cell and a quantum cascade laser (QCL) at 10.33 µm oriented to mobile use. An open-path configuration is used to mitigate sticky-gas effects and achieve high time-response. The final sensor package is relatively small (~20 L), lightweight (~3.5 kg), battery-powered (<30 W) and operates autonomously. Details of the WMS setup and analysis method are presented along with laboratory tests showing sensor accuracy (<~2%) and precision (~4 ppb in 1 s). Initial field deployments on both ground vehicles and a fixed-wing unmanned aerial vehicle (UAV) are also presented.
Open AccessOpen-Path Laser Absorption Sensor for Mobile Measurements of Atmospheric Ammonia
Anthropogenic emissions of ammonia to the atmosphere, particularly those from agricultural sources, can be damaging to the environment and human health and can drive a need for sensor technologies that can be used to detect and quantify the emissions. Mobile sensing approaches that can be deployed on ground-based or aerial vehicles can provide scalable solutions for high throughput measurements but require relatively compact and low-power sensor systems. This contribution presents an ammonia sensor based on wavelength modulation spectroscopy (WMS) integrated with a Herriott multi-pass cell and a quantum cascade laser (QCL) at 10.33 µm oriented to mobile use. An open-path configuration is used to mitigate sticky-gas effects and achieve high time-response. The final sensor package is relatively small (~20 L), lightweight (~3.5 kg), battery-powered (<30 W) and operates autonomously. Details of the WMS setup and analysis method are presented along with laboratory tests showing sensor accuracy (<~2%) and precision (~4 ppb in 1 s). Initial field deployments on both ground vehicles and a fixed-wing unmanned aerial vehicle (UAV) are also presented.
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Chemical Sensing of Trace Gases and Particulate Matter with Optical Cavities
Reliable concentration assessment of the major atmospheric oxidants (hydroxyl free radicals OH, nitrate radicals NO 3 , etc), and their precursors (nitrous acid HONO, nitrogen dioxide NO 2 , and formaldehyde H 2 CO) is essential for understanding the budget of the atmospheric oxidation capacity and then predicting chemical processes that affect regional air quality and global climate change. Real-time in situ monitoring of these key atmospheric species is challenging because of their high reactivity, short lifetimes on the order of minutes or less and ultralow concentrations in the range of pptv (parts per trillion by volume). In gas sensing by Beer-Lambert-based absorption spectroscopy, the absorption intensity follows an exponential law with the optical absorption length, the use of long path absorption schemes is thus the essential way to improve the spectroscopic measurements sensitivity. Optical cavities bridge the gap between sensitivity and spatial scale, delivering long optical pathlengths in a small physical footprint. High finesse optical cavity is usually formed with high reflectivity dielectric mirrors to achieve long optical path lengths of up to a few tens of kilometres for high-sensitivity spectroscopy applications [1].
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Chemical Sensing of Trace Gases and Particulate Matter with Optical Cavities
Reliable concentration assessment of the major atmospheric oxidants (hydroxyl free radicals OH, nitrate radicals NO 3 , etc), and their precursors (nitrous acid HONO, nitrogen dioxide NO 2 , and formaldehyde H 2 CO) is essential for understanding the budget of the atmospheric oxidation capacity and then predicting chemical processes that affect regional air quality and global climate change. Real-time in situ monitoring of these key atmospheric species is challenging because of their high reactivity, short lifetimes on the order of minutes or less and ultralow concentrations in the range of pptv (parts per trillion by volume). In gas sensing by Beer-Lambert-based absorption spectroscopy, the absorption intensity follows an exponential law with the optical absorption length, the use of long path absorption schemes is thus the essential way to improve the spectroscopic measurements sensitivity. Optical cavities bridge the gap between sensitivity and spatial scale, delivering long optical pathlengths in a small physical footprint. High finesse optical cavity is usually formed with high reflectivity dielectric mirrors to achieve long optical path lengths of up to a few tens of kilometres for high-sensitivity spectroscopy applications [1].