TUTuna Unal

Tuna Unal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tuna Unal has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fluorescence compatibility of various resin composites on cervical restorations: An in-vitro evaluation

    by Eminenur Uytun, Elif Alkan, Ezgi Tüter Bayraktar, Tuna Ünal Korkut, Bora Korkut, Dilek Tağtekin

  • Open Access

    Effect of magnification and press-on force on resin composite polishing

    by Tuna Unal, Bora Korkut, Dilek Tağtekin

    To evaluate surface roughness (Ra) and gloss (GU) of two resin composites after polishing with two systems, using a novel press-on force guided (PFG) polishing simulator. Eighty specimens were prepared using Essentia Universal (EU) and G-aenial Universal Injectable (GUI) composites. Surface roughness and gloss were assessed by a profilometer (Marsurf Ps10), and a glossmeter (Novo-Curve). They were polished with Sof-Lex and Twist Dia systems with or without magnification and PFG. Each polishing material was used for 30 s. Ra1 and GU1 measurements were repeated by the same operator. Data were analyzed using One-way ANOVA, Three-way ANOVA, and Robust ANOVA with Bonferroni Correction for multiple comparisons and Spearman’s rho Correlation Coefficient (< 0.050). Higher Ra values were observed in GUI group for Twist Dia (0.33 ± 0.05z) compared to SofLex (0.22 ± 0.08y). Roughness was higher when PFG was uncontrolled (0.31 ± 0.07x), compared to the controlled (0.25 ± 0.09w). No Ra difference was observed in EU group between SofLex (0.33 ± 0.04) and Twist Dia (0.29 ± 0.04)(P = .440). Uncontrolled PFG provided higher gloss for GUI and EU composites (69.7 ± 2.91x, 54.63 ± 18.68x, respectively). Twist Dia presented higher gloss for GUI and EU composites (72.3 ± 2.57z,58.88 ± 13.73z, respectively). Magnification did not affect the roughness or gloss for both composites (P ≥ .05). A moderate negative correlation was found between roughness and gloss in GUI (r=-.546)(P < .001), while no correlation was observed in EU (r=-.110)(P = .449). Higher surface roughness and gloss were observed with uncontrolled (not constant) press-on force. Even though SofLex may provide a lower surface roughness, Twist Dia can generate a greater surface gloss regardless of the composite type. 3.5X loupe magnification was not effective on surface roughness and gloss within a limited polishing time. Press-on force is an important factor affecting the composite polishing quality. Spiral polishing wheels can be advantageous for composite restoration polishing, as they better preserve the secondary and tertiary anatomies and provide a higher gloss. The effect of magnification on composite polishing can be related to the time spent using it.


  • Two‐year retrospective evaluation of monoshade universal composites in direct veneer and diastema closure restorations

    by Bora Korkut, Tuna Ünal, Esra Can

    Objectives: The aim of this retrospective evaluation was to assess the short‐term outcome of two monoshade universal resin composites with high chameleon effect in anterior direct veneer and diastema closure restorations, and to investigate the possible reasons for failure.Material and Methods: Patients subjected to veneer and diastema closure restorations with two monoshade universal resin composites (Essentia Universal Shade; EU, GC Corp., and Omnichroma; OC, Tokuyama) operated between January 2018 and March 2019 were selected for the present retrospective evaluation. A total of 159 composite restorations (78 veneers and 81 diastema closure restorations) performed by a single operator in 44 patients (mean age: 33.6) were included in the study. Two blinded and calibrated examiners performed 1‐ and 2‐year assessments of the restorations with respect to FDI criteria, using medical/clinical history and dental photography records. Data were analyzed using Pearson Chi‐square with Continuity Correction, Fisher's Exact tests, and Cox regression (a < 0.05).Results: The cumulative overall survival rates of EU and OC restorations were 94.6% (97.3% for the first year) and 88.6% (95.3% for the first year), respectively, with no significant difference from each other (p = 0.316). The cumulative overall survival rates of direct veneer and diastema closure restoration types were 90.2% (95.1% for the first year) and 92.4% (97.4% for the first year), respectively, with no significant difference (p = 0.559). The reasons for failure were evaluated as fracture of the restoration, failure in esthetic anatomical form, and color mismatch. All the failed direct veneer restorations were due to fractures (FDI score of 5.4), whereas 5 of 6 failed diastema closure restorations were due to color mismatch (FDI score of 3.4). Regarding the composite materials, there were no significant differences between the success rates of the restoration types (p = 0.442 for EU, p = 1.000 for OC). With respect to the restoration types, there were also no significant differences between the success rates of the resin‐based composites (p = 1.000 for direct veneer restorations and p = 0.228 for the diastema closure restorations). In addition, no significant difference was observed between male and female patients regarding the acceptable and unacceptable scores (p = 1.000).Conclusions: The 2‐year clinical performance of the two monoshade universal composites in anterior veneer and diastema closure restorations were both considered successful and similar. Despite the lack of shade selection, both monoshade universal composites presented a successful color match. However, the diastema closure restorations might be more prone to color mismatch compared to the veneers over time, while veneer restorations presented more fractures than the diastema closure restorations.Clinical Significance: Monoshade universal composites presented successful short‐term clinical outcomes regarding both function and esthetics in anterior direct veneer and diastema closure restorations.


  • The Assessment of the Abrasiveness for Resin Composite Finishing & Polishing Systems

    by Bora Korkut, Tuna Unal

    Objective: This in vitro study was aimed to assess the abrasiveness of 4 different composite finishing and polishing systems, on two different nano-hybrid composite materials. Methods: 40 composite disc samples were prepared 4 mm in diameter and 2 mm in thickness for each nano-hybrid resin composite (Tetric EvoCeram BulkFill A1 body and IPS Empress Direct A1; Ivoclar Vivadent, Schaan, Lichtenstein; n=80 in total). Each composite group was divided into 4 finishing and polishing system subgroups (Sof-Lex Disc, 3M, St. Paul MN, USA; Enhance&Pogo, Dentsply Sirona, Konstanz, Germany; OptraGloss, Ivoclar Vivadent, Shaan, Lichtenstein; Twist Dia, Kuraray Noritake, Tokyo, Japan; n=10 for each subgroup). Single surface of each sample was roughened with 600 and 800 grit sandpapers (Carbimet, Special Silicone Carbide Grinding Paper, IL, USA), respectively. Initial thickness (t1) was measured for each sample with a digital micrometer (BMI 770150, Germany). Then, 4 different finishing&polishing systems were preformed for one side of the samples, at 10 000 rpm, in dry conditions, by a single operator (30 s for a single materal). Final thicknesses (t2) were measured after finishing&polishing procedures. Statistical analyses were performed regarding t2-t1 values. Two-way Anova test was used to assess the level of abrasion for the composite and finishing&polishing materials. Tukey HSD was used for multiple comparisons. Results: In terms of composite materials, IPS Empress Direct presented significantly a greater level of abrasion (52.85 ± 42.26B) than Tetric Evo Ceram Bulk Fill (p < 0.001). In terms of finishing & polishing materials, significantly a greater level of abrasiveness was observed for Sof-Lex Disc (91.25 ± 47.22b) among all (p < 0.001). There was no significant differences in abrasiveness, between Enhance&Pogo - Optragloss (p = 0.859), Enhance&Pogo - Twist Dia (p = 0. 891), and Twist Dia – Optragloss (p = 0.440). Conclusion: Both the type of composite and the finishing & polishing material were considered effective factors for abrasion. The greatest level of abrasiveness was observed for the 4-step Sof-Lex Disc system (91 µm on average), for the total 120 seconds of application. The abrasiveness for the 2-step systems was similar and ranged between 24 – 36 µm on average, for 60 seconds of application. IPS Empress Direct presented a greater level of abrasion than Tetric Evo Ceram Bulk Fill on equal terms of finishing & polishing.