Mimi Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mimi Liu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Bin Wang
Medical Data Science Center, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua Medicine, Tsinghua University, Beijing, China
1 shared publication Chaoxiang Ge
Wenzhou Med Univ, Natl Clin Res Ctr Ocular Dis, Eye Hosp, Wenzhou, Peoples R China
1 shared publication- Chen Yao
Peking University Clinical Research Institute, Peking University First Hospital, Beijing, China
1 shared publication - Feifei Jin
Trauma Medicine Center, Peking University People's Hospital, Beijing, China
1 shared publication - Han Wen
Eye Hospital, WenZhou Medical University, WenZhou, China
1 shared publication - James Chodosh
Department of Ophthalmology and Visual Sciences, University of New Mexico School of Medicine
1 shared publication
Latest Publications
- Open Access
- 13 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
Combined analysis of 16S rDNA sequencing and metabolomics to find biomarkers of drug-induced liver injury
Drug induced liver injury (DILI) is a kind of liver dysfunction which caused by drugs, and gut microbiota could affect liver injury. However, the relationship between gut microbiota and its metabolites in DILI patients is not clear. The total gut microbiota DNA was extracted from 28 DILI patient and 28 healthy control volunteers (HC) and 16S rDNA gene were amplified. Next, differentially metabolites were screened. Finally, the correlations between the diagnostic strains and differentially metabolites were studied.The richness and uniformity of the bacterial communities decreased in DILI patients, and the structure of gut microbiota changed obviously. Enterococcus and Veillonella which belong to Firmicutes increased in DILI, and Blautia and Ralstonia which belong to Firmicutes, Dialister which belongs to Proteobacteria increased in HC. In addition, these diagnostic OTUs of DILI were associated with the DILI damage mechanism. On the other hands, there were 66 differentially metabolites between DILI and HC samples, and these metabolites were mainly enriched in pyrimidine metabolism and steroid hormone biosynthesis pathways. Furthermore, the collinear network map of the key microbiota-metabolites were constructed and the results indicated that Cortodoxone, Prostaglandin I1, Bioyclo Prostaglandin E2 and Anacardic acid were positively correlated with Blautia and Ralstonia, and negatively correlated with Veillonella.This study analyzed the changes of DILI from the perspective of gut microbiota and metabolites. Key strains and differentially metabolites of DILI were screened and the correlations between them were studied. This study further illustrated the mechanism of DILI.
- 13 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
Open AccessCombined analysis of 16S rDNA sequencing and metabolomics to find biomarkers of drug-induced liver injury
Drug induced liver injury (DILI) is a kind of liver dysfunction which caused by drugs, and gut microbiota could affect liver injury. However, the relationship between gut microbiota and its metabolites in DILI patients is not clear. The total gut microbiota DNA was extracted from 28 DILI patient and 28 healthy control volunteers (HC) and 16S rDNA gene were amplified. Next, differentially metabolites were screened. Finally, the correlations between the diagnostic strains and differentially metabolites were studied.The richness and uniformity of the bacterial communities decreased in DILI patients, and the structure of gut microbiota changed obviously. Enterococcus and Veillonella which belong to Firmicutes increased in DILI, and Blautia and Ralstonia which belong to Firmicutes, Dialister which belongs to Proteobacteria increased in HC. In addition, these diagnostic OTUs of DILI were associated with the DILI damage mechanism. On the other hands, there were 66 differentially metabolites between DILI and HC samples, and these metabolites were mainly enriched in pyrimidine metabolism and steroid hormone biosynthesis pathways. Furthermore, the collinear network map of the key microbiota-metabolites were constructed and the results indicated that Cortodoxone, Prostaglandin I1, Bioyclo Prostaglandin E2 and Anacardic acid were positively correlated with Blautia and Ralstonia, and negatively correlated with Veillonella.This study analyzed the changes of DILI from the perspective of gut microbiota and metabolites. Key strains and differentially metabolites of DILI were screened and the correlations between them were studied. This study further illustrated the mechanism of DILI.
- 20 March 2023
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 252, 205-212
Short-Term Outcomes of Modified Boston Type-II Keratoprosthesis Implantation With Autologous Auricular Cartilage Reinforcement
- 20 March 2023
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 252, 205-212
Short-Term Outcomes of Modified Boston Type-II Keratoprosthesis Implantation With Autologous Auricular Cartilage Reinforcement
- Open Access
- 16 December 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (12) , e43229
Electronic Source Data Transcription for Electronic Case Report Forms in China: Validation of the Electronic Source Record Tool in a Real-world Ophthalmology Study
Background: As researchers are increasingly interested in real-world studies (RWSs), improving data collection efficiency and data quality has become an important challenge. An electronic source (eSource) generally includes direct capture, collection, and storage of electronic data to simplify clinical research. It can improve data quality and patient safety and reduce clinical trial costs. Although there are already large projects on eSource technology, there is a lack of experience in using eSource technology to implement RWSs. Our team designed and developed an eSource record (ESR) system in China. In a preliminary prospective study, we selected a cosmetic medical device project to evaluate ESR software’s effect on data collection and transcription. As the previous case verification was simple, we plan to choose more complicated ophthalmology projects to further evaluate the ESR. Objective: We aimed to evaluate the data transcription efficiency and quality of ESR software in retrospective studies to verify the feasibility of using eSource as an alternative to traditional manual transcription of data in RWS projects. Methods: The approved ophthalmic femtosecond laser project was used for ESR case validation. This study compared the efficiency and quality of data transcription between the eSource method using ESR software and the traditional clinical research model of manually transcribing the data. Usability refers to the quality of a user’s experience when interacting with products or systems including websites, software, devices, or applications. To evaluate the system availability of ESR, we used the System Usability Scale (SUS). The questionnaire consisted of the following 2 parts: participant information and SUS evaluation of the electronic medical record (EMR), electronic data capture (EDC), and ESR systems. By accessing log data from the EDC system previously used by the research project, all the time spent from the beginning to the end of the study could be counted. Results: In terms of transcription time cost per field, the eSource method can reduce the time cost by 81.8% (11.2/13.7). Compared with traditional manual data transcription, the eSource method has higher data transcription quality (correct entry rate of 2356/2400, 98.17% vs 47,991/51,424, 93.32%). A total of 15 questionnaires were received with a response rate of 100%. In terms of usability, the average overall SUS scores of the EMR, EDC, and ESR systems were 50.3 (SD 21.9), 51.5 (SD 14.2), and 63.0 (SD 11.3; contract research organization experts: 69.5, SD 11.5; clinicians: 59.8, SD 10.2), respectively. The Cronbach α for the SUS items of the EMR, EDC, and ESR systems were 0.591 (95% CI −0.012 to 0.903), 0.588 (95% CI −0.288 to 0.951), and 0.785 (95% CI 0.576-0.916), respectively. Conclusions: In real-world ophthalmology studies, the eSource approach based on the ESR system can replace the traditional clinical research model that relies on the manual transcription of data.
- 16 December 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (12) , e43229
Open AccessElectronic Source Data Transcription for Electronic Case Report Forms in China: Validation of the Electronic Source Record Tool in a Real-world Ophthalmology Study
Background: As researchers are increasingly interested in real-world studies (RWSs), improving data collection efficiency and data quality has become an important challenge. An electronic source (eSource) generally includes direct capture, collection, and storage of electronic data to simplify clinical research. It can improve data quality and patient safety and reduce clinical trial costs. Although there are already large projects on eSource technology, there is a lack of experience in using eSource technology to implement RWSs. Our team designed and developed an eSource record (ESR) system in China. In a preliminary prospective study, we selected a cosmetic medical device project to evaluate ESR software’s effect on data collection and transcription. As the previous case verification was simple, we plan to choose more complicated ophthalmology projects to further evaluate the ESR. Objective: We aimed to evaluate the data transcription efficiency and quality of ESR software in retrospective studies to verify the feasibility of using eSource as an alternative to traditional manual transcription of data in RWS projects. Methods: The approved ophthalmic femtosecond laser project was used for ESR case validation. This study compared the efficiency and quality of data transcription between the eSource method using ESR software and the traditional clinical research model of manually transcribing the data. Usability refers to the quality of a user’s experience when interacting with products or systems including websites, software, devices, or applications. To evaluate the system availability of ESR, we used the System Usability Scale (SUS). The questionnaire consisted of the following 2 parts: participant information and SUS evaluation of the electronic medical record (EMR), electronic data capture (EDC), and ESR systems. By accessing log data from the EDC system previously used by the research project, all the time spent from the beginning to the end of the study could be counted. Results: In terms of transcription time cost per field, the eSource method can reduce the time cost by 81.8% (11.2/13.7). Compared with traditional manual data transcription, the eSource method has higher data transcription quality (correct entry rate of 2356/2400, 98.17% vs 47,991/51,424, 93.32%). A total of 15 questionnaires were received with a response rate of 100%. In terms of usability, the average overall SUS scores of the EMR, EDC, and ESR systems were 50.3 (SD 21.9), 51.5 (SD 14.2), and 63.0 (SD 11.3; contract research organization experts: 69.5, SD 11.5; clinicians: 59.8, SD 10.2), respectively. The Cronbach α for the SUS items of the EMR, EDC, and ESR systems were 0.591 (95% CI −0.012 to 0.903), 0.588 (95% CI −0.288 to 0.951), and 0.785 (95% CI 0.576-0.916), respectively. Conclusions: In real-world ophthalmology studies, the eSource approach based on the ESR system can replace the traditional clinical research model that relies on the manual transcription of data.