BHBin He

Bin He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bin He has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Front Cover

    by Bin He, Yuxin Zhang, Zhe Meng, Zhijun He, Chengming Wang, Zhenyu Chen, Zichen Yin, Zhangwei Hu, Yejiong Shi, Ning Zhang, et al.

    OCTA can provide in‐vivo 3D microvasculature of bio‐tissue but faces challenges with motion sensitivity and time constraints. Our adaptive, efficient scanning protocol and motion compensation algorithms address these issues. Employing a high‐resolution spectral‐domain OCT system, our innovative OCTA method enhances vascular imaging performance and reconstructs human skin's relative blood speed imaging.Further details can be found in the article by Bin He, Yuxin Zhang, Zhe Meng, Zhijun He, Chengming Wang, Zhenyu Chen, Zichen Yin, Zhangwei Hu, Yejiong Shi, Ning Zhang, Wenxin Zhang, Guihuai Wang, and Ping Xue (e202200340) image

  • Optical coherence tomography angiography with adaptive multi‐time interval

    by Bin He, Yuxin Zhang, Zhe Meng, Zhijun He, Chengming Wang, Zhenyu Chen, Zichen Yin, Zhangwei Hu, Yejiong Shi, Ning Zhang, et al.

    Optical coherence tomography angiography (OCTA) can provide in vivo three‐dimensional microvasculature information of bio‐tissues, but it is sensitive to motion and time‐consuming. To overcome these limitations, we propose an adaptive multiple time interval correlation mapping OCTA with a time‐efficient scanning protocol and motion compensation algorithms. A spectral‐domain OCT with a center wavelength of 850 nm, A‐scan rate of 120 kHz and spatial resolution of 4.1 μm (axial) × 6.9 μm (lateral) is built to reconstruct the microvascular networks in the human arm. By adaptive optimization of the weights of different time interval B‐scan angiograms, our novel OCTA technique achieves better performance with a visible vascular density increase of ~67% and a signal‐to‐noise ratio enhancement of ~11.6%.


  • Whole Brain Micro-Vascular Imaging Using Robot Assisted Optical Coherence Tomography Angiography

    by Bin He, Yuxin Zhang, Zhe Meng, Zhijun He, Zhenyu Chen, Zichen Yin, Zhangwei Hu, Yejiong Shi, Chengming Wang, Xiao Zhang, et al.

    Optical coherence tomography angiography (OCTA) can provide depth resolved image of microvasculature but fail to acquire both high resolution and large field imaging of an irregular sample. The robotic arm can easily scan along the sample surface to ensure that the sample at the same depth is all in the same focal plane, so OCTA can be obtained without the effect of unevenly distributed resolution and fall off as occurred in conventional imaging with linear scanning of irregular sample. So, we integrated a 120 kHz OCT with a robotic arm and proposed a novel calibration method for robotic arm with a repeatability positioning accuracy of ∼60μm. A correlation mapping (CM) masked eigen decomposition OCTA was proposed with CM > 0.6 for binarization to improve the vascular visualization and CM > 0.99 for extraction of big vessels to enhance stitching efficacy. With the aid of robotic arm, micro-vascular OCTA of whole mouse brain was achieved for the first time, to our knowledge, over a volume size of 10 mm × 8.1 mm × 1 mm with a resolution of ∼4μm(axial) x ∼6μm(lateral). We believe robot assisted OCTA system will have great potential in biomedical application like intraoperative navigation and other fields.


  • Open Access

    Dispersion Measurement with Optical Computing Optical Coherence Tomography

    by Wenxin Zhang, Zhengyu Chen, Xiao Zhang, Chengming Wang, Bin He, Ning Liu, Yangkang Wu, Yuxiu Tao, Ning Zhang, Ping Xue

    We propose a novel technique to measure fiber dispersion without any derivative operation and index measurement. Based on the relationship between the dispersion and the signal in optical computing optical coherence tomography, dispersion can be deduced with high accuracy from optical computing OCT signal position and resolution. The group velocity dispersion and third order dispersion of single mode fiber and dispersion compensating fiber with lengths of 10 m–10 km are measured to be in good consistence with the nominal value.