Shunyi Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shunyi Liang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Kezhu Song
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, China
2 shared publications Chengyang Zhu
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, China
1 shared publicationJuncheng Liang
Ionizing Radiation Division, National Institute of Metrology, Beijing, China
1 shared publication- Juncheng Liang
National Institute of Metrology, Beijing, 100029, CHINA
1 shared publication - Yijie Jiang
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China
1 shared publication - Zhijie Yang
National Institute of Metrology, Beijing, 100029, CHINA
1 shared publication
Latest Publications
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05043
Performance optimizations and evaluations for the small direct currents measurement system
Ionization chambers are essential for activity determinations in radionuclide metrology. We have developed a high-precision integrating-differentiating (int-diff) system for measuring small currents. It is anticipated to enhance the ionization current measurement capability of the 4πγ ionization chamber radioactivity standard at the National Institute of Metrology (NIM), China. Besides, it has broad application prospects in physical experiments and fundamental metrology. The design of the measurement system is optimized through circuit analysis and simulation. The structure of the integrating capacitor array is redesigned to reduce the error of the amplification gain, and a relay is used as the reset switch to achieve improved noise and leakage performance. The digital readout and control module is also enhanced in terms of flexibility and functionality. High-precision test platforms utilizing the standard small current source at NIM China and an ionization chamber were developed to evaluate the performance of the system. The results demonstrate an ultra-low noise floor (< 1 fA/√Hz) and a low current bias of fA-level, as well as a low temperature coefficient of the amplification gain of 2.1 ppm/°C. The short-term stability and linearity of the gain are also tested and exhibit comparable indicators to those of the Keithley 6430. Reasonable results are obtained in the long-term reproducibility test. Therefore, the system enables high-precision measurements for small direct currents and shows promise for applications in ionization chambers.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05043
Performance optimizations and evaluations for the small direct currents measurement system
Ionization chambers are essential for activity determinations in radionuclide metrology. We have developed a high-precision integrating-differentiating (int-diff) system for measuring small currents. It is anticipated to enhance the ionization current measurement capability of the 4πγ ionization chamber radioactivity standard at the National Institute of Metrology (NIM), China. Besides, it has broad application prospects in physical experiments and fundamental metrology. The design of the measurement system is optimized through circuit analysis and simulation. The structure of the integrating capacitor array is redesigned to reduce the error of the amplification gain, and a relay is used as the reset switch to achieve improved noise and leakage performance. The digital readout and control module is also enhanced in terms of flexibility and functionality. High-precision test platforms utilizing the standard small current source at NIM China and an ionization chamber were developed to evaluate the performance of the system. The results demonstrate an ultra-low noise floor (< 1 fA/√Hz) and a low current bias of fA-level, as well as a low temperature coefficient of the amplification gain of 2.1 ppm/°C. The short-term stability and linearity of the gain are also tested and exhibit comparable indicators to those of the Keithley 6430. Reasonable results are obtained in the long-term reproducibility test. Therefore, the system enables high-precision measurements for small direct currents and shows promise for applications in ionization chambers.
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (6) , 954-959
A Low-Noise Int-Diff Small Direct Currents Measurement System With Two-Stage Amplifier and Digital Differentiator
Ionization chambers are used as secondary standards in radionuclide metrology. In activity determinations, the measurement of the ionization current is an uncertainty limiting factor, thus requiring precision picoamperemeters with low noise and high stability of transfer coefficient. A small direct current measurement system is presented, including a two-stage amplifier, a filter, a Field Programmable Gate Array (FPGA) and host computer software. It is based on the integrating-differentiating (int-diff) scheme, where the integration function is performed through 100 capacitors and an operational amplifier, while the differentiation function is implemented in the FPGA. Test results with a prototype show a low noise level of 7 fA/√Hz at 100 Hz and no significant DC offset in the transient current measurement waveform. The system has a 10 kHz bandwidth for fast settling, and low-frequency currents can also be measured. Results show that the performance of this system meets design expectations, and can apply to ionization current measurements.
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (6) , 954-959
A Low-Noise Int-Diff Small Direct Currents Measurement System With Two-Stage Amplifier and Digital Differentiator
Ionization chambers are used as secondary standards in radionuclide metrology. In activity determinations, the measurement of the ionization current is an uncertainty limiting factor, thus requiring precision picoamperemeters with low noise and high stability of transfer coefficient. A small direct current measurement system is presented, including a two-stage amplifier, a filter, a Field Programmable Gate Array (FPGA) and host computer software. It is based on the integrating-differentiating (int-diff) scheme, where the integration function is performed through 100 capacitors and an operational amplifier, while the differentiation function is implemented in the FPGA. Test results with a prototype show a low noise level of 7 fA/√Hz at 100 Hz and no significant DC offset in the transient current measurement waveform. The system has a 10 kHz bandwidth for fast settling, and low-frequency currents can also be measured. Results show that the performance of this system meets design expectations, and can apply to ionization current measurements.