Agnieszka Chalaszczyk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Agnieszka Chalaszczyk has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Ester Orlandi
Department of Clinical, Surgical, Diagnostic, and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
5 shared publications - Guido Baroni
Department of Electronics, Information and Bioengineering, Politecnico di Milano (POLIMI), 20133 Milan, Italy
3 shared publications - Maria Rosaria Fiore
Radiation Oncology Unit, Clinical Department, CNAO National Center for Oncological Hadrontherapy, Pavia, Italy
3 shared publications - Amelia Barcellini
Radiation Oncology Unit, Clinical Department, CNAO National Center for Oncological Hadrontherapy, Pavia, Italy
2 shared publications - Andrea Pella
Bioengineering Unit, Clinical Department, CNAO National Center for Oncological Hadrontherapy, 27100 Pavia, Italy
2 shared publications - Chiara Paganelli
Department of Electronics, Information and Bioengineering, Politecnico di Milano (POLIMI), 20133 Milan, Italy
2 shared publications
Latest Publications
- Open Access
- 10 July 2026
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 11 (11)
High-dose carbon ion re-irradiation for recurrent pelvic sarcomas: a retrospective analysis of oncologic outcomes in a referral center.
- 10 July 2026
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 11 (11)
Open AccessHigh-dose carbon ion re-irradiation for recurrent pelvic sarcomas: a retrospective analysis of oncologic outcomes in a referral center.
- Open Access
- 14 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1537
Setup Optimization in Ocular Proton Therapy at the National Centre for Oncological Hadrontherapy: Comparison of Two Approaches to Refine the Position of an Eye-Tracking Device
This study describes a method for setup optimization in patient simulation for ocular proton therapy (OPT) at the National Center for Oncological Hadrontherapy (CNAO) in Pavia, Italy, with the aim of minimizing the occupancy time of clinical areas and streamlining the actual procedure. Setup repeatability is ensured by patient-specific immobilization tools and relies on the patient’s ability to maintain a stable gaze direction according to the treatment plan. This is facilitated by aligning a light source (LED) on a patient-specific base along the prescribed gaze direction. At CNAO, a dedicated Eye-Tracking System (ETS) was designed to provide the patient with a visible source of light aligned to the desired gaze direction. The ETS position is defined prior to treatment planning, relying on optical-tracking guidance and comparing the position of passive markers fixed on the ETS chassis with patient-specific models prepared offline in accordance with the desired geometry. OPT at CNAO started in 2016 and may be considered as a consolidated clinical routine. However, all the preparation phases, including patient-specific ETS models and setup, still require long sessions in clinical areas such as the computed tomography (CT) and the treatment rooms, with a non-negligible impact on other activities. This study describes a novel approach for patient-specific definition of the ETS position and orientation, aiming at minimizing the time required for preparatory activities inside clinical areas. To minimize the occurrence of biases and to reproduce as much as possible a real end-to-end approach, we included in the analysis data of patients that received OPT in our facility. The study was performed in parallel, carrying out the alignment with the standard method currently used in the clinical workflow of CNAO and with the proposed method. Results are presented as 3D residuals and gaze deviations, comparing ETS alignment based on the new approach with respect to the clinical standard method. The preliminary results of this study are evidence of the capability of the procedure to align the ETS position, allowing performing of the procedure in a non-clinical dedicated room.
- 14 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1537
Open AccessSetup Optimization in Ocular Proton Therapy at the National Centre for Oncological Hadrontherapy: Comparison of Two Approaches to Refine the Position of an Eye-Tracking Device
This study describes a method for setup optimization in patient simulation for ocular proton therapy (OPT) at the National Center for Oncological Hadrontherapy (CNAO) in Pavia, Italy, with the aim of minimizing the occupancy time of clinical areas and streamlining the actual procedure. Setup repeatability is ensured by patient-specific immobilization tools and relies on the patient’s ability to maintain a stable gaze direction according to the treatment plan. This is facilitated by aligning a light source (LED) on a patient-specific base along the prescribed gaze direction. At CNAO, a dedicated Eye-Tracking System (ETS) was designed to provide the patient with a visible source of light aligned to the desired gaze direction. The ETS position is defined prior to treatment planning, relying on optical-tracking guidance and comparing the position of passive markers fixed on the ETS chassis with patient-specific models prepared offline in accordance with the desired geometry. OPT at CNAO started in 2016 and may be considered as a consolidated clinical routine. However, all the preparation phases, including patient-specific ETS models and setup, still require long sessions in clinical areas such as the computed tomography (CT) and the treatment rooms, with a non-negligible impact on other activities. This study describes a novel approach for patient-specific definition of the ETS position and orientation, aiming at minimizing the time required for preparatory activities inside clinical areas. To minimize the occurrence of biases and to reproduce as much as possible a real end-to-end approach, we included in the analysis data of patients that received OPT in our facility. The study was performed in parallel, carrying out the alignment with the standard method currently used in the clinical workflow of CNAO and with the proposed method. Results are presented as 3D residuals and gaze deviations, comparing ETS alignment based on the new approach with respect to the clinical standard method. The preliminary results of this study are evidence of the capability of the procedure to align the ETS position, allowing performing of the procedure in a non-clinical dedicated room.
- Open Access
The Role of Carbon Ion Therapy in the Changing Oncology Landscape—A Narrative Review of the Literature and the Decade of Carbon Ion Experience at the Italian National Center for Oncological Hadrontherapy
Background: Currently, 13 Asian and European facilities deliver carbon ion radiotherapy (CIRT) for preclinical and clinical activity, and, to date, 55 clinical studies including CIRT for adult and paediatric solid neoplasms have been registered. The National Center for Oncological Hadrontherapy (CNAO) is the only Italian facility able to accelerate both protons and carbon ions for oncological treatment and research. Methods: To summarise and critically evaluate state-of-the-art knowledge on the application of carbon ion radiotherapy in oncological settings, the authors conducted a literature search till December 2022 in the following electronic databases: PubMed, Web of Science, MEDLINE, Google Scholar, and Cochrane. The results of 68 studies are reported using a narrative approach, highlighting CNAO’s clinical activity over the last 10 years of CIRT. Results: The ballistic and radiobiological hallmarks of CIRT make it an effective option in several rare, radioresistant, and difficult-to-treat tumours. CNAO has made a significant contribution to the advancement of knowledge on CIRT delivery in selected tumour types. Conclusions: After an initial ramp-up period, CNAO has progressively honed its clinical, technical, and dosimetric skills. Growing engagement with national and international networks and research groups for complex cancers has led to increasingly targeted patient selection for CIRT and lowered barriers to facility access.
Open AccessThe Role of Carbon Ion Therapy in the Changing Oncology Landscape—A Narrative Review of the Literature and the Decade of Carbon Ion Experience at the Italian National Center for Oncological Hadrontherapy
Background: Currently, 13 Asian and European facilities deliver carbon ion radiotherapy (CIRT) for preclinical and clinical activity, and, to date, 55 clinical studies including CIRT for adult and paediatric solid neoplasms have been registered. The National Center for Oncological Hadrontherapy (CNAO) is the only Italian facility able to accelerate both protons and carbon ions for oncological treatment and research. Methods: To summarise and critically evaluate state-of-the-art knowledge on the application of carbon ion radiotherapy in oncological settings, the authors conducted a literature search till December 2022 in the following electronic databases: PubMed, Web of Science, MEDLINE, Google Scholar, and Cochrane. The results of 68 studies are reported using a narrative approach, highlighting CNAO’s clinical activity over the last 10 years of CIRT. Results: The ballistic and radiobiological hallmarks of CIRT make it an effective option in several rare, radioresistant, and difficult-to-treat tumours. CNAO has made a significant contribution to the advancement of knowledge on CIRT delivery in selected tumour types. Conclusions: After an initial ramp-up period, CNAO has progressively honed its clinical, technical, and dosimetric skills. Growing engagement with national and international networks and research groups for complex cancers has led to increasingly targeted patient selection for CIRT and lowered barriers to facility access.
- Open Access
A Dosiomics Analysis Based on Linear Energy Transfer and Biological Dose Maps to Predict Local Recurrence in Sacral Chordomas after Carbon-Ion Radiotherapy
Carbon Ion Radiotherapy (CIRT) is one of the most promising therapeutic options to reduce Local Recurrence (LR) in Sacral Chordomas (SC). The aim of this work is to compare the performances of survival models fed with dosiomics features and conventional DVH metrics extracted from relative biological effectiveness (RBE)-weighted dose (DRBE) and dose-averaged Linear Energy Transfer (LETd) maps, towards the identification of possible prognostic factors for LR in SC patients treated with CIRT. This retrospective study included 50 patients affected by SC with a focus on patients that presented a relapse in a high-dose region. Survival models were built to predict both LR and High-Dose Local Recurrencies (HD-LR). The models were evaluated through Harrell Concordance Index (C-index) and patients were stratified into high/low-risk groups. Local Recurrence-free Kaplan–Meier curves were estimated and evaluated through log-rank tests. The model with highest performance (median(interquartile-range) C-index of 0.86 (0.22)) was built on features extracted from LETd maps, with DRBE models showing promising but weaker results (C-index of 0.83 (0.21), 0.80 (0.21)). Although the study should be extended to a wider patient population, LETd maps show potential as a prognostic factor for SC HD-LR in CIRT, and dosiomics appears to be the most promising approach against more conventional methods (e.g., DVH-based).
Open AccessA Dosiomics Analysis Based on Linear Energy Transfer and Biological Dose Maps to Predict Local Recurrence in Sacral Chordomas after Carbon-Ion Radiotherapy
Carbon Ion Radiotherapy (CIRT) is one of the most promising therapeutic options to reduce Local Recurrence (LR) in Sacral Chordomas (SC). The aim of this work is to compare the performances of survival models fed with dosiomics features and conventional DVH metrics extracted from relative biological effectiveness (RBE)-weighted dose (DRBE) and dose-averaged Linear Energy Transfer (LETd) maps, towards the identification of possible prognostic factors for LR in SC patients treated with CIRT. This retrospective study included 50 patients affected by SC with a focus on patients that presented a relapse in a high-dose region. Survival models were built to predict both LR and High-Dose Local Recurrencies (HD-LR). The models were evaluated through Harrell Concordance Index (C-index) and patients were stratified into high/low-risk groups. Local Recurrence-free Kaplan–Meier curves were estimated and evaluated through log-rank tests. The model with highest performance (median(interquartile-range) C-index of 0.86 (0.22)) was built on features extracted from LETd maps, with DRBE models showing promising but weaker results (C-index of 0.83 (0.21), 0.80 (0.21)). Although the study should be extended to a wider patient population, LETd maps show potential as a prognostic factor for SC HD-LR in CIRT, and dosiomics appears to be the most promising approach against more conventional methods (e.g., DVH-based).
- Open Access
The Normal, the Radiosensitive, and the Ataxic in the Era of Precision Radiotherapy: A Narrative Review
(1) Background: radiotherapy is a cornerstone of cancer treatment. When delivering a tumoricidal dose, the risk of severe late toxicities is usually kept below 5% using dose-volume constraints. However, individual radiation sensitivity (iRS) is responsible (with other technical factors) for unexpected toxicities after exposure to a dose that induces no toxicity in the general population. Diagnosing iRS before radiotherapy could avoid unnecessary toxicities in patients with a grossly normal phenotype. Thus, we reviewed iRS diagnostic data and their impact on decision-making processes and the RT workflow; (2) Methods: following a description of radiation toxicities, we conducted a critical review of the current state of the knowledge on individual determinants of cellular/tissue radiation; (3) Results: tremendous advances in technology now allow minimally-invasive genomic, epigenetic and functional testing and a better understanding of iRS. Ongoing large translational studies implement various tests and enriched NTCP models designed to improve the prediction of toxicities. iRS testing could better support informed radiotherapy decisions for individuals with a normal phenotype who experience unusual toxicities. Ethics of medical decisions with an accurate prediction of personalized radiotherapy’s risk/benefits and its health economics impact are at stake; (4) Conclusions: iRS testing represents a critical unmet need to design personalized radiotherapy protocols relying on extended NTCP models integrating iRS.
Open AccessThe Normal, the Radiosensitive, and the Ataxic in the Era of Precision Radiotherapy: A Narrative Review
(1) Background: radiotherapy is a cornerstone of cancer treatment. When delivering a tumoricidal dose, the risk of severe late toxicities is usually kept below 5% using dose-volume constraints. However, individual radiation sensitivity (iRS) is responsible (with other technical factors) for unexpected toxicities after exposure to a dose that induces no toxicity in the general population. Diagnosing iRS before radiotherapy could avoid unnecessary toxicities in patients with a grossly normal phenotype. Thus, we reviewed iRS diagnostic data and their impact on decision-making processes and the RT workflow; (2) Methods: following a description of radiation toxicities, we conducted a critical review of the current state of the knowledge on individual determinants of cellular/tissue radiation; (3) Results: tremendous advances in technology now allow minimally-invasive genomic, epigenetic and functional testing and a better understanding of iRS. Ongoing large translational studies implement various tests and enriched NTCP models designed to improve the prediction of toxicities. iRS testing could better support informed radiotherapy decisions for individuals with a normal phenotype who experience unusual toxicities. Ethics of medical decisions with an accurate prediction of personalized radiotherapy’s risk/benefits and its health economics impact are at stake; (4) Conclusions: iRS testing represents a critical unmet need to design personalized radiotherapy protocols relying on extended NTCP models integrating iRS.