Thomas Dardano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Thomas Dardano has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Quentin Raynaud
Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience Lausanne University Hospital and University of Lausanne Lausanne Switzerland
3 shared publications - Ruud B. van Heeswijk
Department of Radiology Lausanne University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
3 shared publications - Antoine Lutti
Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience Lausanne University Hospital and University of Lausanne Lausanne Switzerland
2 shared publications - Giulia Di Domenicantonio
Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience, Lausanne University Hospital and University of Lausanne
2 shared publications Andre Kuehne
Brightmind.AI GmbH Vienna Austria
1 shared publicationAntoine Lutti
Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience Lausanne University Hospital and University of Lausanne Lausanne Switzerland
1 shared publication
Latest Publications
- Open Access
K-space sampling strategies to reduce noise induced by cardiac pulsatility in brain maps of R 2 * and magnetic susceptibility
Purpose Cardiac pulsation increases the noise level in brain MR images. Maps of the transverse relaxation rate R2* and magnetic susceptibility (QSM) are particularly affected by cardiac-induced noise as they are computed from gradient-echo data acquired at multiple echo times. Here, we introduce two data acquisition strategies to mitigate the impact of cardiac-induced noise in brain maps of R2* and QSM. Methods The proposed strategies are based on the higher level of cardiac-induced noise near the k-space centre. Using a pseudo-spiral sampling trajectory, the first strategy allows for the acquisition of a specific number of averages at each k-space location, set from the local level of cardiac-induced noise. The second strategy synchronizes the acquisition with the cardiac cycle in real time. We compared in 10 healthy volunteers, the variability of data acquired across 4 repetitions and in the same session, using both strategies and with a standard linear trajectory. Results Compared to linear sampling, the pseudo-spiral trajectory reduced the variability of R2* and QSM maps across repetitions by 26/28/22% and 19/18/16% in the brainstem/cerebellum/whole brain, for a 14% increase in scan time. The pseudo-spiral sampling also reduced the level of aliasing artifacts from pulsating blood vessels. The cardiac-triggered trajectory did not reduce the variability of R2* or QSM maps. Conclusion Pseudo-spiral k-space trajectories can be designed to mitigate cardiac-induced noise in brain maps of the MRI parameters R2* and QSM. Synchronization of the acquisition with the cardiac cycle in real time did not lead to any reduction in cardiac-induced noise.
Open AccessK-space sampling strategies to reduce noise induced by cardiac pulsatility in brain maps of R 2 * and magnetic susceptibility
Purpose Cardiac pulsation increases the noise level in brain MR images. Maps of the transverse relaxation rate R2* and magnetic susceptibility (QSM) are particularly affected by cardiac-induced noise as they are computed from gradient-echo data acquired at multiple echo times. Here, we introduce two data acquisition strategies to mitigate the impact of cardiac-induced noise in brain maps of R2* and QSM. Methods The proposed strategies are based on the higher level of cardiac-induced noise near the k-space centre. Using a pseudo-spiral sampling trajectory, the first strategy allows for the acquisition of a specific number of averages at each k-space location, set from the local level of cardiac-induced noise. The second strategy synchronizes the acquisition with the cardiac cycle in real time. We compared in 10 healthy volunteers, the variability of data acquired across 4 repetitions and in the same session, using both strategies and with a standard linear trajectory. Results Compared to linear sampling, the pseudo-spiral trajectory reduced the variability of R2* and QSM maps across repetitions by 26/28/22% and 19/18/16% in the brainstem/cerebellum/whole brain, for a 14% increase in scan time. The pseudo-spiral sampling also reduced the level of aliasing artifacts from pulsating blood vessels. The cardiac-triggered trajectory did not reduce the variability of R2* or QSM maps. Conclusion Pseudo-spiral k-space trajectories can be designed to mitigate cardiac-induced noise in brain maps of the MRI parameters R2* and QSM. Synchronization of the acquisition with the cardiac cycle in real time did not lead to any reduction in cardiac-induced noise.
- Open Access
- 14 September 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 237-251
A characterization of cardiac‐induced noise in R2* maps of the brain
Purpose: Cardiac pulsation increases the noise level in brain maps of the transverse relaxation rate R2*. Cardiac‐induced noise is challenging to mitigate during the acquisition of R2* mapping data because its characteristics are unknown. In this work, we aim to characterize cardiac‐induced noise in brain maps of the MRI parameter R2*.Methods: We designed a sampling strategy to acquire multi‐echo 3D data in 12 intervals of the cardiac cycle, monitored with a fingertip pulse‐oximeter. We measured the amplitude of cardiac‐induced noise in this data and assessed the effect of cardiac pulsation on R2* maps computed across echoes. The area of k‐space that contains most of the cardiac‐induced noise in R2* maps was then identified. Based on these characteristics, we introduced a tentative sampling strategy that aims to mitigate cardiac‐induced noise in R2* maps of the brain.Results: In inferior brain regions, cardiac pulsation accounts for R2* variations of up to 3 s−1 across the cardiac cycle (i.e., ∼35% of the overall variability). Cardiac‐induced fluctuations occur throughout the cardiac cycle, with a reduced intensity during the first quarter of the cycle. A total of 50% to 60% of the overall cardiac‐induced noise is localized near the k‐space center (k < 0.074 mm−1). The tentative cardiac noise mitigation strategy reduced the variability of R2* maps across repetitions by 11% in the brainstem and 6% across the whole brain.Conclusion: We provide a characterization of cardiac‐induced noise in brain R2* maps that can be used as a basis for the design of mitigation strategies during data acquisition.
- 14 September 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 237-251
Open AccessA characterization of cardiac‐induced noise in R2* maps of the brain
Purpose: Cardiac pulsation increases the noise level in brain maps of the transverse relaxation rate R2*. Cardiac‐induced noise is challenging to mitigate during the acquisition of R2* mapping data because its characteristics are unknown. In this work, we aim to characterize cardiac‐induced noise in brain maps of the MRI parameter R2*.Methods: We designed a sampling strategy to acquire multi‐echo 3D data in 12 intervals of the cardiac cycle, monitored with a fingertip pulse‐oximeter. We measured the amplitude of cardiac‐induced noise in this data and assessed the effect of cardiac pulsation on R2* maps computed across echoes. The area of k‐space that contains most of the cardiac‐induced noise in R2* maps was then identified. Based on these characteristics, we introduced a tentative sampling strategy that aims to mitigate cardiac‐induced noise in R2* maps of the brain.Results: In inferior brain regions, cardiac pulsation accounts for R2* variations of up to 3 s−1 across the cardiac cycle (i.e., ∼35% of the overall variability). Cardiac‐induced fluctuations occur throughout the cardiac cycle, with a reduced intensity during the first quarter of the cycle. A total of 50% to 60% of the overall cardiac‐induced noise is localized near the k‐space center (k < 0.074 mm−1). The tentative cardiac noise mitigation strategy reduced the variability of R2* maps across repetitions by 11% in the brainstem and 6% across the whole brain.Conclusion: We provide a characterization of cardiac‐induced noise in brain R2* maps that can be used as a basis for the design of mitigation strategies during data acquisition.
- Open Access
- 6 June 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1695-1712
Dipolectric antenna for high‐field MRI
Purpose: To introduce the dipolectric antenna: a novel RF coil design for high‐field MRI using a combination of a dipole antenna with a loop‐coupled dielectric resonator antenna.Methods: Simulations in human voxel model Duke involving 8‐, 16‐, and 38‐channel dipolectric antenna arrays for brain MRI were conducted. An 8‐channel dipolectric antenna for occipital lobe MRI at 7 T was designed and constructed. The array was built of four dielectric resonator antennas (dielectric constant = 1070) and four segmented dipole antennas. In vivo MRI experiments were conducted in one subject, and the SNR performance was benchmarked against a commercial 32‐channel head coil.Results: A 38‐channel dipolectric antenna array provided the highest whole‐brain SNR (up to a 2.3‐fold SNR gain in the center of the Duke's head vs. an 8‐channel dipolectric antenna array). Dipolectric antenna arrays driven in dipole‐only mode (with dielectric resonators used as receive‐only) yielded the highest transmit performance. The constructed 8‐channel dipolectric antenna array provided up to threefold higher in vivo peripheral SNR when compared with a 32‐channel commercial head coil.Conclusion: Dipolectric antenna can be considered a promising approach to enhance SNR in human brain MRI at 7 T. This strategy can be used to develop novel multi‐channel arrays for different high‐field MRI applications.
- 6 June 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1695-1712
Open AccessDipolectric antenna for high‐field MRI
Purpose: To introduce the dipolectric antenna: a novel RF coil design for high‐field MRI using a combination of a dipole antenna with a loop‐coupled dielectric resonator antenna.Methods: Simulations in human voxel model Duke involving 8‐, 16‐, and 38‐channel dipolectric antenna arrays for brain MRI were conducted. An 8‐channel dipolectric antenna for occipital lobe MRI at 7 T was designed and constructed. The array was built of four dielectric resonator antennas (dielectric constant = 1070) and four segmented dipole antennas. In vivo MRI experiments were conducted in one subject, and the SNR performance was benchmarked against a commercial 32‐channel head coil.Results: A 38‐channel dipolectric antenna array provided the highest whole‐brain SNR (up to a 2.3‐fold SNR gain in the center of the Duke's head vs. an 8‐channel dipolectric antenna array). Dipolectric antenna arrays driven in dipole‐only mode (with dielectric resonators used as receive‐only) yielded the highest transmit performance. The constructed 8‐channel dipolectric antenna array provided up to threefold higher in vivo peripheral SNR when compared with a 32‐channel commercial head coil.Conclusion: Dipolectric antenna can be considered a promising approach to enhance SNR in human brain MRI at 7 T. This strategy can be used to develop novel multi‐channel arrays for different high‐field MRI applications.
- Open Access
A characterization of cardiac-induced noise in R 2 * maps of the brain
Purpose: Cardiac pulsation increases the noise level in brain maps of the transverse relaxation rate R 2 *. Cardiac-induced noise is challenging to mitigate during the acquisition of R 2 * mapping data because its characteristics are unknown. In this work, we therefore aim to characterize cardiac-induced noise in brain maps of the MRI parameter R 2 *. Methods: We designed a sampling strategy to acquire multi-echo 3D data in 12 intervals of the cardiac cycle, monitored with a fingertip pulse-oximeter. We measured the amplitude of cardiac-induced noise in this data and assessed the effect of cardiac pulsation on R 2 * maps computed across echoes. The area of k-space that contains most of the cardiac-induced noise in R 2 * maps was then identified. Based on these characteristics, we introduced a tentative sampling strategy that aims to mitigate cardiac-induced noise in R 2 * maps of the brain. Results: In inferior brain regions, cardiac pulsation accounts for R 2 * variations of up to 3s -1 across the cardiac cycle, i.e. ∼35% of the overall variability. Cardiac-induced fluctuations occur throughout the cardiac cycle, with a reduced intensity during the first quarter of the cycle. 50-60% of the overall cardiac-induced noise is localized near the k-space centre (k < 0.074 mm -1 ). The tentative cardiac noise mitigation strategy reduced the variability of R 2 * maps across repetitions by 11% in the brainstem and 6% across the whole brain. Conclusion: We provide a characterisation of cardiac-induced noise in brain R 2 * maps that can be used as a basis for the design of mitigation strategies during data acquisition.
Open AccessA characterization of cardiac-induced noise in R 2 * maps of the brain
Purpose: Cardiac pulsation increases the noise level in brain maps of the transverse relaxation rate R 2 *. Cardiac-induced noise is challenging to mitigate during the acquisition of R 2 * mapping data because its characteristics are unknown. In this work, we therefore aim to characterize cardiac-induced noise in brain maps of the MRI parameter R 2 *. Methods: We designed a sampling strategy to acquire multi-echo 3D data in 12 intervals of the cardiac cycle, monitored with a fingertip pulse-oximeter. We measured the amplitude of cardiac-induced noise in this data and assessed the effect of cardiac pulsation on R 2 * maps computed across echoes. The area of k-space that contains most of the cardiac-induced noise in R 2 * maps was then identified. Based on these characteristics, we introduced a tentative sampling strategy that aims to mitigate cardiac-induced noise in R 2 * maps of the brain. Results: In inferior brain regions, cardiac pulsation accounts for R 2 * variations of up to 3s -1 across the cardiac cycle, i.e. ∼35% of the overall variability. Cardiac-induced fluctuations occur throughout the cardiac cycle, with a reduced intensity during the first quarter of the cycle. 50-60% of the overall cardiac-induced noise is localized near the k-space centre (k < 0.074 mm -1 ). The tentative cardiac noise mitigation strategy reduced the variability of R 2 * maps across repetitions by 11% in the brainstem and 6% across the whole brain. Conclusion: We provide a characterisation of cardiac-induced noise in brain R 2 * maps that can be used as a basis for the design of mitigation strategies during data acquisition.