QRQuentin Raynaud

Quentin Raynaud

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Quentin Raynaud has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ISME —incoherent sampling of multi‐echo data to minimize cardiac‐induced noise in brain maps of R2*$ {R}_2^{\ast } $ and magnetic susceptibility

    by Quentin Raynaud, Rita Oliveira, Nadège Corbin, Yaël Balbastre, Ruud B. van Heeswijk, Antoine Lutti

    Purpose: Maps of the MRI parameters and magnetic susceptibility () enable the investigation of microscopic tissue changes in brain disease. However, cardiac‐induced signal instabilities increase the variability of brain maps of and . In this study, we introduce incoherent sampling of multi‐echo data (ISME)—a sampling strategy that minimizes the level of cardiac‐induced instabilities in brain maps of and . Methods: ISME uses phase‐encoding gradients to shift the k‐space frequency of the acquired data between consecutive readouts of a multi‐echo train. As a result, the multi‐echo data at a given k‐space index are acquired at different phases of the cardiac cycle. We compare the variability of and maps acquired with ISME and with standard multi‐echo trajectories in N = 10 healthy volunteers. We investigate the effect of both trajectories on the spatial aliasing of pulsating MR signals and propose a weighted least‐squares approach for the estimation of that accounts for the increase of the residuals with echo time. Results: ISME reduces the variability of and maps across repetitions by 25%/26%/21% and 24%/32%/23% in the cerebellum/brainstem/whole brain, respectively. With ISME, the spatial aliasing of pulsating MR signals is incoherent between raw echo images, leading to visually sharper maps. The proposed weighted least‐squares approach for the estimation of reduces the dependence of the fitting residuals on echo time and the variability of by an additional 3%/2%/1% in the cerebellum/brainstem/whole brain. Conclusion: ISME allows the mitigation of cardiac‐induced signal instabilities in brain maps of and , improving reproducibility.


  • Open Access

    In Vivo Characterization of Magnetic Inclusions in the Subcortex From Nonexponential Transverse Relaxation Decay

    by Rita Oliveira, Quentin Raynaud, Ileana Jelescu, Valerij G. Kiselev, Evgeniya Kirilina, Antoine Lutti

    According to theoretical studies, MRI signal decay due to transverse relaxation in brain tissue with magnetic inclusions (e.g., blood vessels and iron‐rich cells) is expected to follow a transition from Gaussian behaviour at short echo times to exponential behaviour at longer times. The decay parameters carry information about the inclusions (e.g., size and volume fraction) and provide unique insights into brain microstructure. However, gradient‐echo decays typically only capture the long‐time exponential behaviour. We provide experimental evidence of nonexponential transverse relaxation decay in human subcortical grey matter from in vivo MRI data acquired at 3 T, allowing the subsequent characterization of the magnetic inclusions. Gradient‐echo data were collected with short interecho spacings, minimal echo time (1.25 ms) and novel acquisition strategies to mitigate motion and cardiac‐induced effects. The data were fitted using exponential and nonexponential models that describe the impact of magnetic inclusions on the MRI signal. Nonexponential models provided superior fits. The strongest deviations from exponential were detected in the substantia nigra and globus pallidus. Numerical simulations of the signal decay from histological maps of iron concentration in the substantia nigra replicated the experimental data, highlighting that non‐haem iron can be at the source of the nonexponential decay. To investigate the potential of nonexponential decays to characterize brain microstructure, we estimated the properties of the underlying inclusions using two analytical models. Under the static dephasing regime, the magnetic susceptibility and volume fractions of the inclusions ranged between 1.8–4 and 0.02–0.04 ppm, respectively. Alternatively, under the diffusion narrowing regime, the typical inclusion size was ~2.4 μm. Both simulations and experimental data suggest an intermediate regime with a non‐negligible effect of water diffusion. Nonexponential transverse relaxation decay allows to characterize the spatial distribution of magnetic material within subcortical tissue with increased specificity, with potential applications for Parkinson's disease and other pathologies.


  • Open Access

    ISME - Incoherent Sampling of Multi-Echo data to minimize cardiac-induced noise in brain maps of R 2 * and magnetic susceptibility

    by Quentin Raynaud, Rita Oliveira, Nadège Corbin, Yaël Balbastre, Ruud B. van Heeswijk, Antoine Lutti

    Purpose Brain maps of the MRI parameters R2* and magnetic susceptibility (χ) enable the investigation of microscopic tissue changes associated with brain disease in patient populations. However, maps of R2* and χ are computed from gradient-echo data acquired at multiple echo times and are affected by cardiac-induced physiological noise. In this study, we introduce ISME – a sampling strategy that minimizes the level of cardiac-induced noise in brain maps of R2* and χ. Methods Cardiac-induced noise causes exponential-like effects on the decay of the signal magnitude that vary across the cardiac cycle, increasing the variability of R2* and χ estimates. ISME uses phase-encoding gradients to shift the k-space frequency of the acquired data between consecutive readouts of a multi-echo train. As a result, the multi-echo data at a given k-space index is acquired at different phases of the cardiac cycle. We compare the variability of R2* and χ maps acquired with ISME and with standard multi-echo trajectories in N=10 healthy volunteers. We also investigate the effect of both sampling strategies on the spatial aliasing of pulsating MR signals in R2* and χ maps and propose a weighted-least square (NWLS) approach for the estimation of R2* that accounts for the increase in cardiac-induced noise with echo time. Results Compared to standard multi-echo trajectories, ISME reduces the variability of R2* and χ across repetitions by 25/26/21% and 24/32/23% in the cerebellum/brainstem/whole brain, respectively. With ISME, the spatial aliasing of pulsating MR signals is incoherent between raw echo images, leading to visually sharper R2* maps. The proposed NWLS approach for the estimation of R2* removes the dependence of the fitting residuals on echo time and brings an additional 3/2/1% reduction of the R2* variability in the cerebellum/brainstem/whole brain. Conclusion ISME allows the mitigation of cardiac-induced noise in brain maps of R2* and χ, improving reproducibility.

  • Open Access

    K-space sampling strategies to reduce noise induced by cardiac pulsatility in brain maps of R 2 * and magnetic susceptibility

    by Quentin Raynaud, Thomas Dardano, Rita Oliveira, Giulia Di Domenicantonio, Tobias Kober, Christopher W. Roy, Ruud B. van Heeswijk, Antoine Lutti

    Purpose Cardiac pulsation increases the noise level in brain MR images. Maps of the transverse relaxation rate R2* and magnetic susceptibility (QSM) are particularly affected by cardiac-induced noise as they are computed from gradient-echo data acquired at multiple echo times. Here, we introduce two data acquisition strategies to mitigate the impact of cardiac-induced noise in brain maps of R2* and QSM. Methods The proposed strategies are based on the higher level of cardiac-induced noise near the k-space centre. Using a pseudo-spiral sampling trajectory, the first strategy allows for the acquisition of a specific number of averages at each k-space location, set from the local level of cardiac-induced noise. The second strategy synchronizes the acquisition with the cardiac cycle in real time. We compared in 10 healthy volunteers, the variability of data acquired across 4 repetitions and in the same session, using both strategies and with a standard linear trajectory. Results Compared to linear sampling, the pseudo-spiral trajectory reduced the variability of R2* and QSM maps across repetitions by 26/28/22% and 19/18/16% in the brainstem/cerebellum/whole brain, for a 14% increase in scan time. The pseudo-spiral sampling also reduced the level of aliasing artifacts from pulsating blood vessels. The cardiac-triggered trajectory did not reduce the variability of R2* or QSM maps. Conclusion Pseudo-spiral k-space trajectories can be designed to mitigate cardiac-induced noise in brain maps of the MRI parameters R2* and QSM. Synchronization of the acquisition with the cardiac cycle in real time did not lead to any reduction in cardiac-induced noise.


  • Open Access

    A characterization of cardiac‐induced noise in R2* maps of the brain

    by Quentin Raynaud, Giulia Di Domenicantonio, Jérôme Yerly, Thomas Dardano, Ruud B. van Heeswijk, Antoine Lutti

    Purpose: Cardiac pulsation increases the noise level in brain maps of the transverse relaxation rate R2*. Cardiac‐induced noise is challenging to mitigate during the acquisition of R2* mapping data because its characteristics are unknown. In this work, we aim to characterize cardiac‐induced noise in brain maps of the MRI parameter R2*.Methods: We designed a sampling strategy to acquire multi‐echo 3D data in 12 intervals of the cardiac cycle, monitored with a fingertip pulse‐oximeter. We measured the amplitude of cardiac‐induced noise in this data and assessed the effect of cardiac pulsation on R2* maps computed across echoes. The area of k‐space that contains most of the cardiac‐induced noise in R2* maps was then identified. Based on these characteristics, we introduced a tentative sampling strategy that aims to mitigate cardiac‐induced noise in R2* maps of the brain.Results: In inferior brain regions, cardiac pulsation accounts for R2* variations of up to 3 s−1 across the cardiac cycle (i.e., ∼35% of the overall variability). Cardiac‐induced fluctuations occur throughout the cardiac cycle, with a reduced intensity during the first quarter of the cycle. A total of 50% to 60% of the overall cardiac‐induced noise is localized near the k‐space center (k < 0.074 mm−1). The tentative cardiac noise mitigation strategy reduced the variability of R2* maps across repetitions by 11% in the brainstem and 6% across the whole brain.Conclusion: We provide a characterization of cardiac‐induced noise in brain R2* maps that can be used as a basis for the design of mitigation strategies during data acquisition.


  • Open Access

    A characterization of cardiac-induced noise in R 2 * maps of the brain

    by Quentin Raynaud, Giulia Di Domenicantonio, Jérôme Yerly, Thomas Dardano, Ruud B. van Heeswijk, Antoine Lutti

    Purpose: Cardiac pulsation increases the noise level in brain maps of the transverse relaxation rate R 2 *. Cardiac-induced noise is challenging to mitigate during the acquisition of R 2 * mapping data because its characteristics are unknown. In this work, we therefore aim to characterize cardiac-induced noise in brain maps of the MRI parameter R 2 *. Methods: We designed a sampling strategy to acquire multi-echo 3D data in 12 intervals of the cardiac cycle, monitored with a fingertip pulse-oximeter. We measured the amplitude of cardiac-induced noise in this data and assessed the effect of cardiac pulsation on R 2 * maps computed across echoes. The area of k-space that contains most of the cardiac-induced noise in R 2 * maps was then identified. Based on these characteristics, we introduced a tentative sampling strategy that aims to mitigate cardiac-induced noise in R 2 * maps of the brain. Results: In inferior brain regions, cardiac pulsation accounts for R 2 * variations of up to 3s -1 across the cardiac cycle, i.e. ∼35% of the overall variability. Cardiac-induced fluctuations occur throughout the cardiac cycle, with a reduced intensity during the first quarter of the cycle. 50-60% of the overall cardiac-induced noise is localized near the k-space centre (k < 0.074 mm -1 ). The tentative cardiac noise mitigation strategy reduced the variability of R 2 * maps across repetitions by 11% in the brainstem and 6% across the whole brain. Conclusion: We provide a characterisation of cardiac-induced noise in brain R 2 * maps that can be used as a basis for the design of mitigation strategies during data acquisition.