KLKian Djien Liem

Kian Djien Liem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kian Djien Liem has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A review of existing neonatal hyperbilirubinemia guidelines in Indonesia

    by Mahendra Tri Arif Sampurna, Danny Chandra Pratama, Visuddho Visuddho, Novita Oktaviana, Achmad Januar Er Putra, Rahmi Zakiyah, Jordy Maulana Ahmad, Risa Etika, Kartika Darma Handayani, Martono Tri Utomo, et al.

    Background Neonatal hyperbilirubinemia is one of the most common conditions for neonate inpatients. Indonesia faces a major challenge in which different guidelines regarding the management of this condition were present. This study aimed to compare the existing guidelines regarding prevention, diagnosis, treatment and monitoring in order to create the best recommendation for a new hyperbilirubinemia guideline in Indonesia. Methods Through an earlier survey regarding adherence to the neonatal hyperbilirubinemia guideline, we identified that three main guidelines are being used in Indonesia. These were developed by the Indonesian Pediatric Society (IPS), the Ministry of Health (MoH), and World Health Organization (WHO). In this study, we compared factors such as prevention, monitoring, methods for identifying, risk factors in the development of neonatal jaundice, risk factors that increase brain damage, and intervention treatment threshold in the existing guidelines to determine the best recommendations for a new guideline. Results The MoH and WHO guidelines allow screening and treatment of hyperbilirubinemia based on visual examination (VE) only. Compared with the MoH and WHO guidelines, risk assessment is comprehensively discussed in the IPS guideline. The MoH guideline recommends further examination of an icteric baby to ensure that the mother has enough milk without measuring the bilirubin level. The MoH guideline recommends referring the baby when it looks yellow on the soles and palms. The WHO and IPS guidelines recommend combining VE with an objective measurement of transcutaneous or serum bilirubin. The threshold to begin phototherapy in the WHO guideline is lower than the IPS guideline while the exchange transfusion threshold in both guidelines are comparably equal. Conclusions The MoH guideline is outdated. MoH and IPS guidelines are causing differences in approaches to the management hyperbilirubinemia. A new, uniform guideline is required.


  • Open Access

    An Affordable phototherapy intensity meter using machine learning to improve the quality of care system for Hyperbilirubinemia in Indonesia

    by Yosi Kristian, Mahendra Tri Arif Sampurna, Evan Kusuma Susanto, Visuddho Visuddho, Kian Djien Liem

    Hyperbilirubinemia is more frequently seen in low and middle-income countries like Indonesia. One of the contributing factors is a substandard dose of Phototherapy irradiance. This research aims to design a phototherapy intensity meter called PhotoInMeter using readily available low-cost components. PhotoInMeter is designed by using a microcontroller, light sensor, color sensor, and an ND (neutral-density) filter. We use machine learning to create a mathematical model that converts the emission from the color sensor and light sensor into light intensity measurements that are close to Ohmeda Biliblanket’s measurements. Our prototype collects sensor reading data and pairs them with Ohmeda Biliblanket Light Meter to create a training set for our machine learning algorithm. We create a multivariate linear regression, random forest, and XGBoost model based on our training set to convert sensor readings to Ohmeda Biliblanket Light Meter measurement. We successfully devised a prototype that costs 20 times less to produce compared to our reference intensity meter while still having high accuracy. Compared to Ohmeda Biliblanket Light Meter, our PhotoInMeter has a Mean Absolute Error (MAE) of 0.83 and achieves more than a 0.99 correlation score in all six different devices for intensity in the range of 0–90 μW/cm2/nm. Our prototypes show consistent reading between PhotoInMeter devices, having an average difference of 0.435 among all six devices.


  • NEOnatal Central-venous Line Observational study on Thrombosis (NEOCLOT): evaluation of a national guideline on management of neonatal catheter-related venous thrombosis

    by C. Heleen van Ommen, Klasien A. Bergman, Marit Boerma, Heleen A. Bouma, Albertine E. Donker, Melissa Gouvernante, Christian V. Hulzebos, Dalila Khandour, Ronny Knol, Marlou A. Raets, et al.


  • Open Access

    A review of existing neonatal hyperbilirubinemia guidelines in Indonesia

    by Mahendra Tri Arif Sampurna, Kian Djien Liem, Danny Chandra Pratama, Novita Oktaviana, Achmad Januar Er Putra, Rahmi Zakiyah, Visuddho Visuddho, Risa Etika, Kartika Dharma Handayani, Martono Tri Utomo, et al.

    Background: Neonatal hyperbilirubinemia is one of the most common conditions for neonate inpatients. Indonesia faces a major challenge in which different guidelines regarding the management of this condition were present. This study aimed to compare the existing guidelines regarding prevention, diagnosis, treatment and monitoring in order to create the best recommendation for a new hyperbilirubinemia guideline in Indonesia. Methods: Through an earlier survey regarding adherence to the neonatal hyperbilirubinemia guideline, we identified that three main guidelines are being used in Indonesia. These were developed by the Indonesian Pediatric Society (IPS), the Ministry of Health (MoH), and World Health Organization (WHO). In this study, we compared factors such as prevention, monitoring, methods for identifying, risk factors in the development of neonatal jaundice, risk factors that increase brain damage, and intervention treatment threshold in the existing guidelines to determine the best recommendations for a new guideline. Results: The MoH and WHO guidelines allow screening and treatment of hyperbilirubinemia based on visual examination (VE) only. Compared with the MoH and WHO guidelines, risk assessment is comprehensively discussed in the IPS guideline. The MoH guideline recommends further examination of an icteric baby to ensure that the mother has enough milk without measuring the bilirubin level. The MoH guideline recommends referring the baby when it looks yellow on the soles and palms. The WHO and IPS guidelines recommend combining VE with an objective measurement of transcutaneous or serum bilirubin. The threshold to begin phototherapy in the WHO guideline is lower than the IPS guideline while the exchange transfusion threshold in both guidelines are comparably equal. Conclusions: The MoH guideline is outdated. MoH and IPS guidelines are causing differences in approaches to the management hyperbilirubinemia. A new, uniform guideline is required.


  • Open Access

    Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs

    by S. L. Vrancken, W. P. de Boode, J. C. Hopman, S. K. Singh, K. D. Liem, A. F. van Heijst

    Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a left-to-right shunt. Regular arterial and central venous catheters were inserted into seven lambs (3.5–8.3 kg). A surgically constructed left-to-right aorto-pulmonary Gore-Tex® shunt was intermittently opened and closed, while CO was manipulated by creating haemorrhagic hypotension. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe positioned around the main pulmonary artery (COufp). We performed 72 sessions of three paired CO measurements. The mean COufp was 1.00 litre min−1 (range 0.47–1.75 litre min−1) and mean COtpud 1.05 litre min−1 (range 0.54–1.87 litre min−1). With an open shunt, the mean Qp/Qs ratio was 1.8 (range 1.3–2.6). A comparison between COufp and COtpud showed a mean bias (sd) of 0.03 (0.09) and 0.07 (0.10) litre min−1, respectively, for measurements with a closed and an open shunt. The percentage error was 18% and 20% for measurements with a closed and an open shunt. Polar plot analysis showed good trending ability for both closed and open shunt groups. TPUD is a reliable technology to measure CO in the presence of a left-to-right shunt.