Yuanfeng Qi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuanfeng Qi has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Baoxin Ge
5 shared publicationsChang Xu
3 shared publicationsQinyan Yue
3 shared publicationsBaoyu Gao
2 shared publicationsBo Jiang
School of Environmental and Municipal Engineering, Qingdao University of Technology, Qingdao,266033, PR China
2 shared publicationsChangzhi Wang
Environmental Science Research and Design Institute of Zhejiang Province, Hangzhou 310007, China
2 shared publications
Latest Publications
- 22 December 2025
- Published by Elsevier in Bioresource Technology
- Vol. 443, 133823
Recycled biochar-based powdery reagent for degradation of organic chromium complex dye: preparation, evaluation and kinetic modeling
- 22 December 2025
- Published by Elsevier in Bioresource Technology
- Vol. 443, 133823
Recycled biochar-based powdery reagent for degradation of organic chromium complex dye: preparation, evaluation and kinetic modeling
- 11 March 2025
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 197 (4) , 1-15
Comprehensive source tracing and process supervision of coating industrial wastewater using integrated water quality parameters and fluorescence spectroscopy
Rapid industrialization has led to the concentration of heavily polluting industries, such as coatings, in industrial parks, resulting in significant volumes of hazardous wastewater. Effective inflow management and process monitoring are essential for the stable operation of wastewater treatment plants. This study collected samples from a coating industrial park and its treatment plant to analyze water quality. Fluorescence spectra were analyzed using parallel factor analysis (PARAFAC) to identify specific components. A fluorescence peak at Ex/Em = 350/425 nm was detected, indicating the presence of aromatic hydrocarbons. Conventional treatment, which primarily includes physical and chemical methods such as coagulation, flocculation, and activated sludge processes, was ineffective in removing these substances, while Fenton precipitation successfully degraded them. UV254 showed significant correlations with the biological index (BIX) (r = − 0.52) and fluorescence component C1 (r = 0.85), suggesting its potential as a pollutant marker. Component C4, identified as lignin-like, is characteristic of coating industry materials. These findings highlight the potential of fluorescence spectroscopy and PARAFAC for tracing wastewater sources and monitoring pollutant degradation in industrial treatment plants.
- 11 March 2025
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 197 (4) , 1-15
Comprehensive source tracing and process supervision of coating industrial wastewater using integrated water quality parameters and fluorescence spectroscopy
Rapid industrialization has led to the concentration of heavily polluting industries, such as coatings, in industrial parks, resulting in significant volumes of hazardous wastewater. Effective inflow management and process monitoring are essential for the stable operation of wastewater treatment plants. This study collected samples from a coating industrial park and its treatment plant to analyze water quality. Fluorescence spectra were analyzed using parallel factor analysis (PARAFAC) to identify specific components. A fluorescence peak at Ex/Em = 350/425 nm was detected, indicating the presence of aromatic hydrocarbons. Conventional treatment, which primarily includes physical and chemical methods such as coagulation, flocculation, and activated sludge processes, was ineffective in removing these substances, while Fenton precipitation successfully degraded them. UV254 showed significant correlations with the biological index (BIX) (r = − 0.52) and fluorescence component C1 (r = 0.85), suggesting its potential as a pollutant marker. Component C4, identified as lignin-like, is characteristic of coating industry materials. These findings highlight the potential of fluorescence spectroscopy and PARAFAC for tracing wastewater sources and monitoring pollutant degradation in industrial treatment plants.
- Open Access
Science and Technology for Water Purification: Achievements and Strategies
Water scarcity and pollution remain two of the most pressing global challenges, with profound implications for public health, environmental sustainability, and economic development
Open AccessScience and Technology for Water Purification: Achievements and Strategies
Water scarcity and pollution remain two of the most pressing global challenges, with profound implications for public health, environmental sustainability, and economic development
- Open Access
Pipeline Leak Identification and Prediction of Urban Water Supply Network System with Deep Learning Artificial Neural Network
Pipeline leakage, which leads to water wastage, financial losses, and contamination, is a significant challenge in urban water supply networks. Leak detection and prediction is urgent to secure the safety of the water supply system. Relaying on deep learning artificial neural networks and a specific optimization algorithm, an intelligential detection approach in identifying the pipeline leaks is proposed. A hydraulic model is initially constructed on the simplified Net2 benchmark pipe network. The District Metering Area (DMA) algorithm and the Cuckoo Search (CS) algorithm are integrated as the DMA-CS algorithm, which is employed for the hydraulic model optimization. Attributing to the suspected leak area identification and the exact leak location, the DMA-CS algorithm possess higher accuracy for pipeline leakage (97.43%) than that of the DMA algorithm (92.67%). The identification pattern of leakage nodes is correlated to the maximum number of leakage points set with the participation of the DMA-CS algorithm, which provide a more accurate pathway for identifying and predicting the specific pipeline leaks.
Open AccessPipeline Leak Identification and Prediction of Urban Water Supply Network System with Deep Learning Artificial Neural Network
Pipeline leakage, which leads to water wastage, financial losses, and contamination, is a significant challenge in urban water supply networks. Leak detection and prediction is urgent to secure the safety of the water supply system. Relaying on deep learning artificial neural networks and a specific optimization algorithm, an intelligential detection approach in identifying the pipeline leaks is proposed. A hydraulic model is initially constructed on the simplified Net2 benchmark pipe network. The District Metering Area (DMA) algorithm and the Cuckoo Search (CS) algorithm are integrated as the DMA-CS algorithm, which is employed for the hydraulic model optimization. Attributing to the suspected leak area identification and the exact leak location, the DMA-CS algorithm possess higher accuracy for pipeline leakage (97.43%) than that of the DMA algorithm (92.67%). The identification pattern of leakage nodes is correlated to the maximum number of leakage points set with the participation of the DMA-CS algorithm, which provide a more accurate pathway for identifying and predicting the specific pipeline leaks.
- 19 December 2022
- Published by Elsevier in Journal of Cleaner Production
- Vol. 384
Blockchain-like analysis strategy for two distinct “White-box” modeling methodologies to simulate the incineration of oily sludge- 19 December 2022
- Published by Elsevier in Journal of Cleaner Production
- Vol. 384
Blockchain-like analysis strategy for two distinct “White-box” modeling methodologies to simulate the incineration of oily sludge- Open Access
- 6 December 2022
- Published by IOS Press
- p. 718-727
Modified-FWO-Algorithm for Complex “White-Box” Thermal Kinetic Model: A Case Application on Amphotericin Residue Incineration
A Modified-FWO-Algorithm was proposed to modify the drawbacks of the traditional FWO-Algorithm throughout the construction of incineration kinetics model for complex pollutants. And the implementation process of this algorithm was introduced via the construction of amphotericin residue incineration kinetic model. The results indicate that two stages emerged in TG/DTG analysis of amphotericin residue, and reactions related to those stages are both multi-step reaction. "White-Box" incineration kinetic model established on Modified-FWO-Algorithm possessed the lowest RMSE value was 0.43%. Data reproducibility of the model derived Modified-FWO-Algorithm was 24.54 times higher than established by FWO-Algorithm.
- 6 December 2022
- Published by IOS Press
- p. 718-727
Open AccessModified-FWO-Algorithm for Complex “White-Box” Thermal Kinetic Model: A Case Application on Amphotericin Residue Incineration
A Modified-FWO-Algorithm was proposed to modify the drawbacks of the traditional FWO-Algorithm throughout the construction of incineration kinetics model for complex pollutants. And the implementation process of this algorithm was introduced via the construction of amphotericin residue incineration kinetic model. The results indicate that two stages emerged in TG/DTG analysis of amphotericin residue, and reactions related to those stages are both multi-step reaction. "White-Box" incineration kinetic model established on Modified-FWO-Algorithm possessed the lowest RMSE value was 0.43%. Data reproducibility of the model derived Modified-FWO-Algorithm was 24.54 times higher than established by FWO-Algorithm.
- Open Access
Demulsification Treatment of Spent Metalworking Fluids by Metal Cations: The Synergistic Effect and Efficiency Evaluation
In this paper, various metal ions were utilized for the demulsification of spent metalworking fluids discharged from an automobile parts workshop. Five types of metal ions, i.e., Fe3+, Al3+, Fe2+, Ca2+ and Mg2+, combined with coagulant were systematically evaluated, and the synergistic effect as well as the optimum operating conditions were studied. The results indicated that the Ca2+ as well Mg2+ possessed hardly efficiency for the demulsification, on the contrary, Fe2+ reduced the yield of the by-product sludge and lowered the SV30 ratio, and Al3+ boosted the CODCr removal. Furthermore, Fe3+ and Al3+ had a significant synergistic effect to achieve a better transmittance and a higher CODCr/SV30 ratio which revealed that more CODCr was removed, as well as less by-product sludge was generated. For a better demulsification of spent metalworking fluids, the optimum operating conditions were gathered as follows: the dosage of metal ions was 0.08 mol/L with Al3+:Fe3+ ratio was 1.5:1, the reaction pH was 6.00, the reaction time was 18.00 min and the temperature was 323.00 K. Based on this, the CODCr removal, the SV30 ratio and the transmittance and CODCr/SV30 ratio of the spent metalworking fluids were 80.21%, 40.00%, 95.20% and 128.33 mg/mL, respectively. This combined metal ion demulsification method possessed an advantageous minimization of spent metalworking fluids, which greatly benefited the automobile parts workshops in cutting down the operating cost in environmental protection.
Open AccessDemulsification Treatment of Spent Metalworking Fluids by Metal Cations: The Synergistic Effect and Efficiency Evaluation
In this paper, various metal ions were utilized for the demulsification of spent metalworking fluids discharged from an automobile parts workshop. Five types of metal ions, i.e., Fe3+, Al3+, Fe2+, Ca2+ and Mg2+, combined with coagulant were systematically evaluated, and the synergistic effect as well as the optimum operating conditions were studied. The results indicated that the Ca2+ as well Mg2+ possessed hardly efficiency for the demulsification, on the contrary, Fe2+ reduced the yield of the by-product sludge and lowered the SV30 ratio, and Al3+ boosted the CODCr removal. Furthermore, Fe3+ and Al3+ had a significant synergistic effect to achieve a better transmittance and a higher CODCr/SV30 ratio which revealed that more CODCr was removed, as well as less by-product sludge was generated. For a better demulsification of spent metalworking fluids, the optimum operating conditions were gathered as follows: the dosage of metal ions was 0.08 mol/L with Al3+:Fe3+ ratio was 1.5:1, the reaction pH was 6.00, the reaction time was 18.00 min and the temperature was 323.00 K. Based on this, the CODCr removal, the SV30 ratio and the transmittance and CODCr/SV30 ratio of the spent metalworking fluids were 80.21%, 40.00%, 95.20% and 128.33 mg/mL, respectively. This combined metal ion demulsification method possessed an advantageous minimization of spent metalworking fluids, which greatly benefited the automobile parts workshops in cutting down the operating cost in environmental protection.
- 1 June 2021
- Published by Elsevier in Science of The Total Environment
- Vol. 774, 145751
Application of sectionalized single-step reaction approach (SSRA) and distributed activation energy model (DAEM) on the pyrolysis kinetics model of upstream oily sludge: Construction procedure and data reproducibility comparison
- 1 June 2021
- Published by Elsevier in Science of The Total Environment
- Vol. 774, 145751
Application of sectionalized single-step reaction approach (SSRA) and distributed activation energy model (DAEM) on the pyrolysis kinetics model of upstream oily sludge: Construction procedure and data reproducibility comparison