Xiaolan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiaolan Li has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Kunqi Li
Nankai Univ, Inst Modern Opt, Tianjin Key Lab Microscale Opt Informat Sci & Tech, 38 Tongyan Rd,Haihe Educ Pk, Tianjin 300350, Peoples R China
2 shared publications Lin Zhang
Tianjin Medical University
2 shared publications- Yongji Liu
Nankai University
2 shared publications - Yuwei Xing
Nankai Univ, Inst Modern Opt, Tianjin Key Lab Microscale Opt Informat Sci & Tech, 38 Tongyan Rd,Haihe Educ Pk, Tianjin 300350, Peoples R China
2 shared publications Congzheng Wang
Tianjin University
1 shared publication- Dongyu Liu
Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Institute of Modern Optics, Nankai University, 38 Tongyan Road, Haihe Education Park, Tianjin 300350, China
1 shared publication
Latest Publications
- 22 May 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (6) , 2821-2838
Approach to the design of different types of intraocular lenses based on an improved sinusoidal profile
An approach is presented to design different types of Intraocular lenses (IOLs) with a uniform optimization algorithm. An improved sinusoidal phase function is proposed to realize adjustable energy allocations in different diffractive orders according to the design aims. By setting specific optimization goals, different types of IOLs can be designed using the same optimization algorithm. With this method, bifocal, trifocal, extended-depth-of-focus (EDoF), and mono-EDoF IOLs are successfully designed and their optical performance under monochromatic and polychromatic light is evaluated and compared with their commercial counterparts. The result shows that most of the designed IOLs, even though they don’t have any multi-zones or combination of diffractive profiles, have superior or comparable performance to their commercial counterparts in terms of optical performance under monochromatic light. The result demonstrates the validity and reliability of the approach proposed in this paper. With this method, the development time of different types of IOLs could be reduced considerably.
- 22 May 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (6) , 2821-2838
Approach to the design of different types of intraocular lenses based on an improved sinusoidal profile
An approach is presented to design different types of Intraocular lenses (IOLs) with a uniform optimization algorithm. An improved sinusoidal phase function is proposed to realize adjustable energy allocations in different diffractive orders according to the design aims. By setting specific optimization goals, different types of IOLs can be designed using the same optimization algorithm. With this method, bifocal, trifocal, extended-depth-of-focus (EDoF), and mono-EDoF IOLs are successfully designed and their optical performance under monochromatic and polychromatic light is evaluated and compared with their commercial counterparts. The result shows that most of the designed IOLs, even though they don’t have any multi-zones or combination of diffractive profiles, have superior or comparable performance to their commercial counterparts in terms of optical performance under monochromatic light. The result demonstrates the validity and reliability of the approach proposed in this paper. With this method, the development time of different types of IOLs could be reduced considerably.
- 1 September 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (9) , 5067-5081
Effectiveness of collagen cross-linking induced by two-photon absorption properties of a femtosecond laser in ex vivo human corneal stroma
This study aimed to investigate the effectiveness of two-photon induced collagen cross-linking (CXL) using femtosecond lasers in human corneal stroma. An 800-nm femtosecond laser optical path for CXL was established. Corneal samples that received two-photon induced CXL and ultraviolet-A (UVA) CXL underwent uniaxial stretching experiments, proteolytic resistance assays and observation of collagen fiber structure changes. Two-photon induced CXL can achieve corneal stiffening effects comparable to UVA CXL and showed better advantages at low strains. The cornea after two-photon induced CXL exhibited high enzymatic resistance and tight collagen fiber arrangement. Two-photon induced CXL promises to be a new option for keratoconus.
- 1 September 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (9) , 5067-5081
Effectiveness of collagen cross-linking induced by two-photon absorption properties of a femtosecond laser in ex vivo human corneal stroma
This study aimed to investigate the effectiveness of two-photon induced collagen cross-linking (CXL) using femtosecond lasers in human corneal stroma. An 800-nm femtosecond laser optical path for CXL was established. Corneal samples that received two-photon induced CXL and ultraviolet-A (UVA) CXL underwent uniaxial stretching experiments, proteolytic resistance assays and observation of collagen fiber structure changes. Two-photon induced CXL can achieve corneal stiffening effects comparable to UVA CXL and showed better advantages at low strains. The cornea after two-photon induced CXL exhibited high enzymatic resistance and tight collagen fiber arrangement. Two-photon induced CXL promises to be a new option for keratoconus.
- 25 August 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (9) , 4939-4953
Comparison of wavefront aberrations in the object and image spaces using wide-field individual eye models
Wavefront aberrations in the image space are critical for visual perception, though the clinical available instruments usually give the wavefront aberrations in the object space. This study aims to compare the aberrations in the object and image spaces. With the measured wavefront aberrations over the horizontal and vertical ±15° visual fields, the in-going and out-going wide-field individual myopic eye models were constructed to obtain the wavefront aberrations in the object and image spaces of the same eye over ±45° horizontal and vertical visual fields. The average differences in the mean sphere and astigmatism were below 0.25 D between the object and image spaces over the horizontal and vertical ±45° visual fields under 3 mm and 6 mm pupil diameter. The wavefront aberrations in the object space are a proper representation of the aberrations in the image space at least for horizontal visual fields ranging from -35°to +35° and vertical visual fields ranging from -15°to +15°.
- 25 August 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (9) , 4939-4953
Comparison of wavefront aberrations in the object and image spaces using wide-field individual eye models
Wavefront aberrations in the image space are critical for visual perception, though the clinical available instruments usually give the wavefront aberrations in the object space. This study aims to compare the aberrations in the object and image spaces. With the measured wavefront aberrations over the horizontal and vertical ±15° visual fields, the in-going and out-going wide-field individual myopic eye models were constructed to obtain the wavefront aberrations in the object and image spaces of the same eye over ±45° horizontal and vertical visual fields. The average differences in the mean sphere and astigmatism were below 0.25 D between the object and image spaces over the horizontal and vertical ±45° visual fields under 3 mm and 6 mm pupil diameter. The wavefront aberrations in the object space are a proper representation of the aberrations in the image space at least for horizontal visual fields ranging from -35°to +35° and vertical visual fields ranging from -15°to +15°.