Yongji Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yongji Liu has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Kunqi Li
Nankai Univ, Inst Modern Opt, Tianjin Key Lab Microscale Opt Informat Sci & Tech, 38 Tongyan Rd,Haihe Educ Pk, Tianjin 300350, Peoples R China
4 shared publications - Yuwei Xing
Nankai Univ, Inst Modern Opt, Tianjin Key Lab Microscale Opt Informat Sci & Tech, 38 Tongyan Rd,Haihe Educ Pk, Tianjin 300350, Peoples R China
4 shared publications - Dongyu Liu
Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Institute of Modern Optics, Nankai University, 38 Tongyan Road, Haihe Education Park, Tianjin 300350, China
2 shared publications - Hongliang Liu
Nankai University
2 shared publications - Xiaolan Li
Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Institute of Modern Optics, Nankai University, 38 Tongyan Road, Haihe Education Park, Tianjin, 300350, China
2 shared publications Xiaoqin Chen
Tianjin Eye Hospital Optometric Center
2 shared publications
Latest Publications
- 13 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (21) , 39853
Design and experimental evaluation of a rotationally symmetric zonal aspheric lens for early presbyopia correction
Progressive addition lenses (PALs) are inherently associated with peripheral astigmatism arising from their progressive optical architecture. We developed a rotationally symmetric zonal aspheric lens (ZAL) as an alternative approach for early presbyopia correction. The ZAL was designed using an eye model adapted to the participant's refractive prescription, fabricated, and experimentally characterized. Compared with a commercial PAL, the ZAL reproduced the intended power distribution and exhibited reduced peripheral astigmatism. A preliminary 14-day binocular wear evaluation was conducted in a single participant. Visual acuity and recognition accuracy were comparable between the ZALs and PALs, whereas median reaction time was longer with the ZALs (956.94 vs. 907.47 ms, p < 0.001). These findings demonstrate the feasibility of the proposed optical architecture and indicate that reduced peripheral astigmatism does not necessarily translate into faster functional visual responses under the present testing conditions.
- 13 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (21) , 39853
Design and experimental evaluation of a rotationally symmetric zonal aspheric lens for early presbyopia correction
Progressive addition lenses (PALs) are inherently associated with peripheral astigmatism arising from their progressive optical architecture. We developed a rotationally symmetric zonal aspheric lens (ZAL) as an alternative approach for early presbyopia correction. The ZAL was designed using an eye model adapted to the participant's refractive prescription, fabricated, and experimentally characterized. Compared with a commercial PAL, the ZAL reproduced the intended power distribution and exhibited reduced peripheral astigmatism. A preliminary 14-day binocular wear evaluation was conducted in a single participant. Visual acuity and recognition accuracy were comparable between the ZALs and PALs, whereas median reaction time was longer with the ZALs (956.94 vs. 907.47 ms, p < 0.001). These findings demonstrate the feasibility of the proposed optical architecture and indicate that reduced peripheral astigmatism does not necessarily translate into faster functional visual responses under the present testing conditions.
- 7 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1344-1358
Experimental and modeling analysis of lenses with concentric cylindrical annular refractive elements: impact on peripheral imaging
The mechanism by which myopia-managing spectacle lenses slow myopia progression remains controversial. Understanding the changes these lenses introduce to peripheral imaging properties helps shed light on this controversial issue. Given the difficulty of directly measuring these changes in clinical settings, this study combined experimental and modeling approaches to evaluate changes in images at the retina induced by myopia-managing lenses. Optical characteristics that may related to the efficacy of the lenses with concentric cylindrical annular refractive elements (CARE) in myopia control were investigated. Three lenses were evaluated: MyoCare (MC), MyoCare S (MCS), and a single vision (SV) lens with a custom-built physical eye model and optical simulations for the analysis. The simulated PSFs are consistent with the measured ones. PSF analysis showed that MC and MCS lenses produce discrete curves, resulting in remarkable distortion in the simulated retina images, especially for large eccentricities. Whether they increase or decrease contrast depends on the spatial frequencies and eccentricities. These lenses also increase retinal light intensity at different eccentricities. The positive power of the CARE structure introduces myopic defocus of less than 0.25 D at only a limited range of eccentricities. The proposed approaches present relatively straightforward techniques for evaluating the optical performance of myopia-managing spectacle lenses.
- 7 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1344-1358
Experimental and modeling analysis of lenses with concentric cylindrical annular refractive elements: impact on peripheral imaging
The mechanism by which myopia-managing spectacle lenses slow myopia progression remains controversial. Understanding the changes these lenses introduce to peripheral imaging properties helps shed light on this controversial issue. Given the difficulty of directly measuring these changes in clinical settings, this study combined experimental and modeling approaches to evaluate changes in images at the retina induced by myopia-managing lenses. Optical characteristics that may related to the efficacy of the lenses with concentric cylindrical annular refractive elements (CARE) in myopia control were investigated. Three lenses were evaluated: MyoCare (MC), MyoCare S (MCS), and a single vision (SV) lens with a custom-built physical eye model and optical simulations for the analysis. The simulated PSFs are consistent with the measured ones. PSF analysis showed that MC and MCS lenses produce discrete curves, resulting in remarkable distortion in the simulated retina images, especially for large eccentricities. Whether they increase or decrease contrast depends on the spatial frequencies and eccentricities. These lenses also increase retinal light intensity at different eccentricities. The positive power of the CARE structure introduces myopic defocus of less than 0.25 D at only a limited range of eccentricities. The proposed approaches present relatively straightforward techniques for evaluating the optical performance of myopia-managing spectacle lenses.
- 7 June 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (18) , 4773-4781
Design and performance evaluation of an enhanced monofocal intraocular lens
Enhanced monofocal intraocular lenses (IOLs), aimed at improving intermediate vision while maintaining distance vision comparable to traditional monofocal IOLs, are emerging as a promising option for cataract surgery. This study introduces a method for designing such enhanced monofocal IOL and conducts a thorough investigation of its optical performance. Additionally, the visual acuity (VA) of the pseudophakic eye implanted with the designed IOL is examined. The designed IOL provides image quality for distance vision comparable to that of monofocal IOLs and a depth of focus of 1.30 D, demonstrating its ability to improve intermediate vision. Moreover, the optical performance of the designed IOL based on this method can be comparable to commercial products, in terms of the modulation transfer function (MTF). The designed enhanced monofocal IOL demonstrates a potential for real application in cataract surgery.
- 7 June 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (18) , 4773-4781
Design and performance evaluation of an enhanced monofocal intraocular lens
Enhanced monofocal intraocular lenses (IOLs), aimed at improving intermediate vision while maintaining distance vision comparable to traditional monofocal IOLs, are emerging as a promising option for cataract surgery. This study introduces a method for designing such enhanced monofocal IOL and conducts a thorough investigation of its optical performance. Additionally, the visual acuity (VA) of the pseudophakic eye implanted with the designed IOL is examined. The designed IOL provides image quality for distance vision comparable to that of monofocal IOLs and a depth of focus of 1.30 D, demonstrating its ability to improve intermediate vision. Moreover, the optical performance of the designed IOL based on this method can be comparable to commercial products, in terms of the modulation transfer function (MTF). The designed enhanced monofocal IOL demonstrates a potential for real application in cataract surgery.
- 24 May 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (6) , 3932-3949
Fabrication and performance evaluation of a design for an extended depth-of-focus intraocular lens based on an improved sinusoidal profile
This study presents the fabrication and evaluation of a sinusoidal extended depth-of-focus (EDoF) intraocular lens (IOL) based on our previously proposed design approach. The power, through-focus MTF, and surface profile were measured using commercial instruments. Through-focus images of a United States Air Force (USAF) 1951 resolution target formed by the fabricated IOL were compared with Symfony and AR40E under monochromatic and polychromatic light using optical bench testing. Simulations assessed visual acuity (VA) of a pseudophakic model eye with the EDoF IOL, including evaluation of tilt and decentration effects. Results indicate that the base power, add power, and the through-focus MTF@50 lp/mm of the fabricated IOL at a 3 mm pupil size align with the design specifications. The extended-depth-of-focus and imaging performance for the far vision of the fabricated IOL under both monochromatic and polychromatic light conditions at a 3.0 mm pupil diameter is comparable to that of Symfony. In addition, the fabricated IOL exhibits a similar extended-depth-of-focus for three discrete wavelengths. The pseudophakic model eye with the designed EDoF IOL demonstrates a VA exceeding 0.1 logMAR within a defocus range of 2.44 D. The VA is tolerant to both IOL tilt and decentration. These findings demonstrate the promising potential of the sinusoidal EDoF IOL design for future applications in cataract surgery.
- 24 May 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (6) , 3932-3949
Fabrication and performance evaluation of a design for an extended depth-of-focus intraocular lens based on an improved sinusoidal profile
This study presents the fabrication and evaluation of a sinusoidal extended depth-of-focus (EDoF) intraocular lens (IOL) based on our previously proposed design approach. The power, through-focus MTF, and surface profile were measured using commercial instruments. Through-focus images of a United States Air Force (USAF) 1951 resolution target formed by the fabricated IOL were compared with Symfony and AR40E under monochromatic and polychromatic light using optical bench testing. Simulations assessed visual acuity (VA) of a pseudophakic model eye with the EDoF IOL, including evaluation of tilt and decentration effects. Results indicate that the base power, add power, and the through-focus MTF@50 lp/mm of the fabricated IOL at a 3 mm pupil size align with the design specifications. The extended-depth-of-focus and imaging performance for the far vision of the fabricated IOL under both monochromatic and polychromatic light conditions at a 3.0 mm pupil diameter is comparable to that of Symfony. In addition, the fabricated IOL exhibits a similar extended-depth-of-focus for three discrete wavelengths. The pseudophakic model eye with the designed EDoF IOL demonstrates a VA exceeding 0.1 logMAR within a defocus range of 2.44 D. The VA is tolerant to both IOL tilt and decentration. These findings demonstrate the promising potential of the sinusoidal EDoF IOL design for future applications in cataract surgery.
- 22 May 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (6) , 2821-2838
Approach to the design of different types of intraocular lenses based on an improved sinusoidal profile
An approach is presented to design different types of Intraocular lenses (IOLs) with a uniform optimization algorithm. An improved sinusoidal phase function is proposed to realize adjustable energy allocations in different diffractive orders according to the design aims. By setting specific optimization goals, different types of IOLs can be designed using the same optimization algorithm. With this method, bifocal, trifocal, extended-depth-of-focus (EDoF), and mono-EDoF IOLs are successfully designed and their optical performance under monochromatic and polychromatic light is evaluated and compared with their commercial counterparts. The result shows that most of the designed IOLs, even though they don’t have any multi-zones or combination of diffractive profiles, have superior or comparable performance to their commercial counterparts in terms of optical performance under monochromatic light. The result demonstrates the validity and reliability of the approach proposed in this paper. With this method, the development time of different types of IOLs could be reduced considerably.
- 22 May 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (6) , 2821-2838
Approach to the design of different types of intraocular lenses based on an improved sinusoidal profile
An approach is presented to design different types of Intraocular lenses (IOLs) with a uniform optimization algorithm. An improved sinusoidal phase function is proposed to realize adjustable energy allocations in different diffractive orders according to the design aims. By setting specific optimization goals, different types of IOLs can be designed using the same optimization algorithm. With this method, bifocal, trifocal, extended-depth-of-focus (EDoF), and mono-EDoF IOLs are successfully designed and their optical performance under monochromatic and polychromatic light is evaluated and compared with their commercial counterparts. The result shows that most of the designed IOLs, even though they don’t have any multi-zones or combination of diffractive profiles, have superior or comparable performance to their commercial counterparts in terms of optical performance under monochromatic light. The result demonstrates the validity and reliability of the approach proposed in this paper. With this method, the development time of different types of IOLs could be reduced considerably.
- Open Access
Design and Optical Analysis of a Refractive Aspheric Intraocular Lens with Extended Depth of Focus
To obtain a continuous range of clear vision for pseudophakic eyes, a design of intraocular lens (IOL) with extended depth of focus (EDoF) was proposed. The IOL was optimized with a multi-configuration approach based on a pseudophakic eye model and the optical performances of the designed IOL were analyzed. The modulation transfer function (MTF) values remain above 0.2 at 50 lp/mm for object distance ranging from 0.35 m to infinity in both photopic vision and mesopic vision over a field of 4°. The optical performances remain stable when the pupil diameter changes from 2.25 mm to 5 mm. Besides, the presented theoretical analyses show the designed IOL has good optical performances for polychromatic light and corneal asphericity. The above shows that the IOL exhibits an excellent ability for pseudophakic eyes to see the object in a continuous range of distance.
Open AccessDesign and Optical Analysis of a Refractive Aspheric Intraocular Lens with Extended Depth of Focus
To obtain a continuous range of clear vision for pseudophakic eyes, a design of intraocular lens (IOL) with extended depth of focus (EDoF) was proposed. The IOL was optimized with a multi-configuration approach based on a pseudophakic eye model and the optical performances of the designed IOL were analyzed. The modulation transfer function (MTF) values remain above 0.2 at 50 lp/mm for object distance ranging from 0.35 m to infinity in both photopic vision and mesopic vision over a field of 4°. The optical performances remain stable when the pupil diameter changes from 2.25 mm to 5 mm. Besides, the presented theoretical analyses show the designed IOL has good optical performances for polychromatic light and corneal asphericity. The above shows that the IOL exhibits an excellent ability for pseudophakic eyes to see the object in a continuous range of distance.
- 25 August 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (9) , 4939-4953
Comparison of wavefront aberrations in the object and image spaces using wide-field individual eye models
Wavefront aberrations in the image space are critical for visual perception, though the clinical available instruments usually give the wavefront aberrations in the object space. This study aims to compare the aberrations in the object and image spaces. With the measured wavefront aberrations over the horizontal and vertical ±15° visual fields, the in-going and out-going wide-field individual myopic eye models were constructed to obtain the wavefront aberrations in the object and image spaces of the same eye over ±45° horizontal and vertical visual fields. The average differences in the mean sphere and astigmatism were below 0.25 D between the object and image spaces over the horizontal and vertical ±45° visual fields under 3 mm and 6 mm pupil diameter. The wavefront aberrations in the object space are a proper representation of the aberrations in the image space at least for horizontal visual fields ranging from -35°to +35° and vertical visual fields ranging from -15°to +15°.
- 25 August 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (9) , 4939-4953
Comparison of wavefront aberrations in the object and image spaces using wide-field individual eye models
Wavefront aberrations in the image space are critical for visual perception, though the clinical available instruments usually give the wavefront aberrations in the object space. This study aims to compare the aberrations in the object and image spaces. With the measured wavefront aberrations over the horizontal and vertical ±15° visual fields, the in-going and out-going wide-field individual myopic eye models were constructed to obtain the wavefront aberrations in the object and image spaces of the same eye over ±45° horizontal and vertical visual fields. The average differences in the mean sphere and astigmatism were below 0.25 D between the object and image spaces over the horizontal and vertical ±45° visual fields under 3 mm and 6 mm pupil diameter. The wavefront aberrations in the object space are a proper representation of the aberrations in the image space at least for horizontal visual fields ranging from -35°to +35° and vertical visual fields ranging from -15°to +15°.
- 1 January 2020
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Chinese Optics
- Vol. 13 (4) , 770-777
Analysis of the corneal surface and peripheral defocus after orthokeratology
- 1 January 2020
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Chinese Optics
- Vol. 13 (4) , 770-777
Analysis of the corneal surface and peripheral defocus after orthokeratology
- 1 January 2018
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 16 (9) , 093301
Design of double-zone aspheric diffractive intraocular lens with extended depth of focus
A double-zone aspheric diffractive intraocular lens (IOL) was designed and manufactured aiming to regain a continuous range of clear vision for pseudophakic presbyopia. After obtaining the IOL structure parameters through optimization based on an aphakic model eye, its imaging performances were analyzed in the model eye. The modulation transfer function at 50 cycles/mm remained above 0.29 within ±5° field of view for object distance ranging from 6 to 0.66 m. In addition, the imaging qualities are robust for pupil changes, polychromatic light, and different corneal asphericities. The manufactured IOL exhibits the ability to extend depth of focus.
- 1 January 2018
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 16 (9) , 093301
Design of double-zone aspheric diffractive intraocular lens with extended depth of focus
A double-zone aspheric diffractive intraocular lens (IOL) was designed and manufactured aiming to regain a continuous range of clear vision for pseudophakic presbyopia. After obtaining the IOL structure parameters through optimization based on an aphakic model eye, its imaging performances were analyzed in the model eye. The modulation transfer function at 50 cycles/mm remained above 0.29 within ±5° field of view for object distance ranging from 6 to 0.66 m. In addition, the imaging qualities are robust for pupil changes, polychromatic light, and different corneal asphericities. The manufactured IOL exhibits the ability to extend depth of focus.
- 14 June 2012
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 32 (4) , 355-361
Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia
Citation information: Liu Y, Wang Y, Wang Z & Zuo T. Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia. Ophthalmic Physiol Opt 2012, 32 , 355–361. doi: 10.1111/j.1475‐1313.2012.00921.x Purpose: To investigate the sources of error in corneal power measurement before and after corneal refractive surgery for myopia. Methods: The study comprised 28 eyes of six males and eight females with a mean age of 26 (range 18–39 years). The radius of curvature of anterior and posterior corneal surface, Q ‐Values of anterior and posterior corneal surface and corneal central thickness were measured by rotating Scheimpflug imaging (Pentacam). The true net power F g , back vertex power F v , and keratometric power SimK , were calculated respectively at the apex and at a paracentral area on the 3 mm ring. Results: For virgin eyes, the overestimation (0.53 ± 0.11 D) of the corneal power by using a keratometric index of 1.3375 was balanced by the underestimation (−0.21 ± 0.09 D) of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error with a mean value of 0.33 ± 0.11 D. With the Q ‐value changing from −0.09 to −0.41, the percentage balanced by the error in radius of curvature increased from 16% to 73%. However, for eyes after laser refractive surgery, the radius of curvature error lead to an overestimation (0.54 ± 0.16 D) of the corneal power and the keratometric index of 1.3375 again overestimated (1.59 ± 0.26 D) the corneal power, resulting in a large measurement error with a mean value of 2.12 ± 0.40 D. With the Q ‐value changing from 0.35 to 1.89, the percentage added by the error in radius of curvature increased from 14% to 32%. Conclusions: For virgin eyes, the overestimation of the corneal power by using a keratometric index of 1.3375 is balanced by the underestimation of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error. However, for eyes after laser refractive surgery, the flatter anterior corneal surface means that the use of a keratometric index of 1.3375 significantly overestimates the corneal power and the radius of curvature error now adds to this overestimation and results in a large measurement error.
- 14 June 2012
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 32 (4) , 355-361
Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia
Citation information: Liu Y, Wang Y, Wang Z & Zuo T. Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia. Ophthalmic Physiol Opt 2012, 32 , 355–361. doi: 10.1111/j.1475‐1313.2012.00921.x Purpose: To investigate the sources of error in corneal power measurement before and after corneal refractive surgery for myopia. Methods: The study comprised 28 eyes of six males and eight females with a mean age of 26 (range 18–39 years). The radius of curvature of anterior and posterior corneal surface, Q ‐Values of anterior and posterior corneal surface and corneal central thickness were measured by rotating Scheimpflug imaging (Pentacam). The true net power F g , back vertex power F v , and keratometric power SimK , were calculated respectively at the apex and at a paracentral area on the 3 mm ring. Results: For virgin eyes, the overestimation (0.53 ± 0.11 D) of the corneal power by using a keratometric index of 1.3375 was balanced by the underestimation (−0.21 ± 0.09 D) of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error with a mean value of 0.33 ± 0.11 D. With the Q ‐value changing from −0.09 to −0.41, the percentage balanced by the error in radius of curvature increased from 16% to 73%. However, for eyes after laser refractive surgery, the radius of curvature error lead to an overestimation (0.54 ± 0.16 D) of the corneal power and the keratometric index of 1.3375 again overestimated (1.59 ± 0.26 D) the corneal power, resulting in a large measurement error with a mean value of 2.12 ± 0.40 D. With the Q ‐value changing from 0.35 to 1.89, the percentage added by the error in radius of curvature increased from 14% to 32%. Conclusions: For virgin eyes, the overestimation of the corneal power by using a keratometric index of 1.3375 is balanced by the underestimation of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error. However, for eyes after laser refractive surgery, the flatter anterior corneal surface means that the use of a keratometric index of 1.3375 significantly overestimates the corneal power and the radius of curvature error now adds to this overestimation and results in a large measurement error.