Andreas Lindner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andreas Lindner has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Oliver J. Muensterer
Department of Pediatric Surgery, Dr. von Hauner Children’s Hospital, LMU University Hospital, Munich, Munich, Germany
4 shared publications - Franz-Xaver Anzinger
Clinic for Paediatric Surgery, Dr. von Hauner Children’s Hospital, University Hospital of LMU Munich, Munich, Bavaria, Germany
2 shared publications - Jan Goedeke
Department of Pediatric Surgery, Dr. von Hauner Children’s Hospital, LMU University Hospital, Munich, Munich, Germany
2 shared publications - Julia Haehl
Department of Pediatric Surgery, Dr. von Hauner Children’s Hospital, University Hospital, LMU Munich, Munich, Germany
2 shared publications Kayoung Heo
Global Surgery Lab, Branch for Global Surgical Care, Department of Surgery, University of British Columbia, Department of Psychiatry
2 shared publicationsM. Riboldi
Ludwig‐Maximilians‐University of Munich | LMU, Chair for Experimental Physics Munich Germany
2 shared publications
Latest Publications
- Open Access
- 11 February 2026
- Published by Elsevier in Seminars in Pediatric Surgery
- Vol. 41, 151584
A novel dynamic in-vitro model of esophageal button battery ingestion demonstrating benefits of honey, but not acetic acid
- 11 February 2026
- Published by Elsevier in Seminars in Pediatric Surgery
- Vol. 41, 151584
Open AccessA novel dynamic in-vitro model of esophageal button battery ingestion demonstrating benefits of honey, but not acetic acid
- Open Access
- 29 January 2026
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 61 (6) , 162955
Molding mastery: Validation of a 3D-Printed simulator for pediatric inguinal hernia repair
- 29 January 2026
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 61 (6) , 162955
Open AccessMolding mastery: Validation of a 3D-Printed simulator for pediatric inguinal hernia repair
- Open Access
- 11 April 2025
- Published by Wiley in Pediatric Pulmonology
- Vol. 60 (4) , e71090
Comparative Analysis of Analog and Digital Chest Tube Drainage Systems Using a High‐Fidelity 3D‐Printed Neonatal Chest Model
Background: In recent years, digital chest tube drainage systems have been introduced. Limited studies address their benefits and risks in pediatric patients, particularly neonates. This study compares a three‐chamber chest drainage system with a digital system using a high‐fidelity 3D‐printed model.Methods: We conducted direct measurements and 3D‐printed model tests with both systems at different suction pressures (−1 to −20 cmH2O) to assess the actual pressures. The effects of siphon and automatic flushes in the digital system were also studied.Results: At −20 and −10 cmH2O, significant differences were found between the digital and analog systems in direct and model measurements. The analog system became unreliable below −10 cmH2O. For the digital system, most measurements remained within the set pressures, with outliers up to −30 cmH2O due to regular flushing.Conclusion: This experimental study evaluates the suitability of digital drainage systems for the pediatric and neonatal populations. Our model demonstrated reliable simulation of thoracic conditions, making it a useful tool for pre‐clinical testing where patient testing may be limited. Both systems yielded satisfactory results at −20 and −10 cmH2O, but the digital system showed greater flexibility, maintaining pressures as low as −5 cmH2O. The analog system was consistent but less adaptable, which may limit its use in dynamic situations. The digital system's ability to simulate more flexible scenarios offers potential clinical advantages, though further investigation is needed to assess its impact on neonatal safety. The increase in suction during flushing may pose a risk for neonatal patients.
- 11 April 2025
- Published by Wiley in Pediatric Pulmonology
- Vol. 60 (4) , e71090
Open AccessComparative Analysis of Analog and Digital Chest Tube Drainage Systems Using a High‐Fidelity 3D‐Printed Neonatal Chest Model
Background: In recent years, digital chest tube drainage systems have been introduced. Limited studies address their benefits and risks in pediatric patients, particularly neonates. This study compares a three‐chamber chest drainage system with a digital system using a high‐fidelity 3D‐printed model.Methods: We conducted direct measurements and 3D‐printed model tests with both systems at different suction pressures (−1 to −20 cmH2O) to assess the actual pressures. The effects of siphon and automatic flushes in the digital system were also studied.Results: At −20 and −10 cmH2O, significant differences were found between the digital and analog systems in direct and model measurements. The analog system became unreliable below −10 cmH2O. For the digital system, most measurements remained within the set pressures, with outliers up to −30 cmH2O due to regular flushing.Conclusion: This experimental study evaluates the suitability of digital drainage systems for the pediatric and neonatal populations. Our model demonstrated reliable simulation of thoracic conditions, making it a useful tool for pre‐clinical testing where patient testing may be limited. Both systems yielded satisfactory results at −20 and −10 cmH2O, but the digital system showed greater flexibility, maintaining pressures as low as −5 cmH2O. The analog system was consistent but less adaptable, which may limit its use in dynamic situations. The digital system's ability to simulate more flexible scenarios offers potential clinical advantages, though further investigation is needed to assess its impact on neonatal safety. The increase in suction during flushing may pose a risk for neonatal patients.
- Open Access
- 10 February 2025
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 60 (5) , 162232
Iterative Design and Manufacturing of a 3D-Printed Pediatric Open and Laparoscopic Integrated Simulator for Hernia Repair (POLISHeR)
- 10 February 2025
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 60 (5) , 162232
Open AccessIterative Design and Manufacturing of a 3D-Printed Pediatric Open and Laparoscopic Integrated Simulator for Hernia Repair (POLISHeR)
- Open Access
- 19 November 2024
- Published by Wiley
Comparative Analysis of Analog and Digital Thoracic Drainage Systems Using a High-Fidelity 3D-Printed Neonatal Chest Phantom
Background: In recent years, digital thoracic drainage systems have been introduced. Limited studies address the benefits and risks in pediatric patients. We compared analog and digital systems using a high-fidelity 3D-printed phantom. Methods: Direct measurements as well as measurements on a 3D-printed phantom were conducted employing a digital and analog system for different suction pressures (-1 to -20 cmH 2 O). The impact of a siphon and automatic flushes of the digital system were studied. Results: At pressure settings of -20 and -10 cmH 2 O, direct and phantom measurements yielded significantly different results for the digital compared to the analog system. Set pressures below -10 cmH 2 O in the analog drainage system were unreliable. For the digital system, the majority of measured points fell within the chosen settings. There were statistical outliers up to -30 cmH 2 O attributed to the regular flushing performed by the system. Conclusion: This is the first experimental study objectifying the suitability of digital drainage systems for the pediatric and neonatal population. Our phantom produced accurate results where tests on patients are not possible. At suction pressures of -20 and -10 cmH 2 O the digital and the analog drainage system yield satisfactory results. The digital system was able to maintain pressures as low as -5 cmH 2 O. The analog drainage system is less flexible but remains a reliable tool for experienced users. The digital drainage system allows more freedom and can increase patient safety by neutralizing obstructions or a siphon. The increase in suction during flushing may pose a risk for neonatal patients.
- 19 November 2024
- Published by Wiley
Open AccessComparative Analysis of Analog and Digital Thoracic Drainage Systems Using a High-Fidelity 3D-Printed Neonatal Chest Phantom
Background: In recent years, digital thoracic drainage systems have been introduced. Limited studies address the benefits and risks in pediatric patients. We compared analog and digital systems using a high-fidelity 3D-printed phantom. Methods: Direct measurements as well as measurements on a 3D-printed phantom were conducted employing a digital and analog system for different suction pressures (-1 to -20 cmH 2 O). The impact of a siphon and automatic flushes of the digital system were studied. Results: At pressure settings of -20 and -10 cmH 2 O, direct and phantom measurements yielded significantly different results for the digital compared to the analog system. Set pressures below -10 cmH 2 O in the analog drainage system were unreliable. For the digital system, the majority of measured points fell within the chosen settings. There were statistical outliers up to -30 cmH 2 O attributed to the regular flushing performed by the system. Conclusion: This is the first experimental study objectifying the suitability of digital drainage systems for the pediatric and neonatal population. Our phantom produced accurate results where tests on patients are not possible. At suction pressures of -20 and -10 cmH 2 O the digital and the analog drainage system yield satisfactory results. The digital system was able to maintain pressures as low as -5 cmH 2 O. The analog drainage system is less flexible but remains a reliable tool for experienced users. The digital drainage system allows more freedom and can increase patient safety by neutralizing obstructions or a siphon. The increase in suction during flushing may pose a risk for neonatal patients.
- 22 December 2022
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 58 (4) , 675-678
SuSiPed: An initial step towards a universal, low-cost, 3D-printable platform for pediatric minimal-invasive surgery training
- 22 December 2022
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 58 (4) , 675-678
SuSiPed: An initial step towards a universal, low-cost, 3D-printable platform for pediatric minimal-invasive surgery training