HIHisashi Ibuki

Hisashi Ibuki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hisashi Ibuki has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Objective Macular Asymmetry Metrics for Glaucoma Detection Using a Temporal Raphe–Based OCT Linearization Algorithm

    by Takuhei Shoji, Miho Seo, Hisashi Ibuki, Hirokazu Ishii, Junji Kanno, Kei Shinoda

    Background/Objectives: We aim to develop an image linearization process and a program capable of quantifying vertical and left–right asymmetries observed in macular scans. We then sought to verify its applicability in clinical settings. Methods: In this single-center cross-sectional study, we examined 37 consecutive patients with unilateral open-angle glaucoma and analyzed paired data (glaucomatous eye vs. fellow normal eye). Spectral-domain OCT images were automatically processed by a custom program to align the disc–fovea axis and temporal raphe, and the following parameters were evaluated: (1) mean inner retinal thickness difference (superior–inferior), (2) Vertical Asymmetry Score, and (3) Quadrantal Asymmetry Score. Results: We analyzed 37 healthy eyes and 37 POAG eyes. After linearization, the mean inner retinal thicknesses for the normal and POAG groups were 93.4 µm (interquartile range [IQR]: 90.1–98.5) and 80.3 µm (IQR: 77.3–85.0), respectively. The Vertical Asymmetry Score was 6.80 (IQR: 6.15–7.25) for healthy eyes and 9.69 (IQR: 9.16–11.58) for POAG eyes. The Quadrantal Asymmetry Score was 6.35 (IQR: 5.94–7.19) for healthy eyes and 8.47 (IQR: 8.11–9.63) for POAG eyes. Significant differences were found between groups for all parameters (p < 0.001). The Vertical Asymmetry Score (AUC = 0.967, p < 0.001) and Quadrantal Asymmetry Score (AUC = 0.946, p < 0.001) demonstrated significantly greater accuracy in detecting glaucoma compared to the mean inner retinal thickness (AUC = 0.743). Conclusions: The developed linearization program and asymmetry scores have shown promise as parameters for objectively quantifying macular asymmetry using spectral-domain OCT. External validation in independent cohorts, including bilateral disease, is warranted.


  • Open Access

    Deep Learning with a Dataset Created Using Kanno Saitama Macro, a Self-Made Automatic Foveal Avascular Zone Extraction Program

    by Junji Kanno, Takuhei Shoji, Hirokazu Ishii, Hisashi Ibuki, Yuji Yoshikawa, Takanori Sasaki, Kei Shinoda

    The extraction of the foveal avascular zone (FAZ) from optical coherence tomography angiography (OCTA) images has been used in many studies in recent years due to its association with various ophthalmic diseases. In this study, we investigated the utility of a dataset for deep learning created using Kanno Saitama Macro (KSM), a program that automatically extracts the FAZ using swept-source OCTA. The test data included 40 eyes of 20 healthy volunteers. For training and validation, we used 257 eyes from 257 patients. The FAZ of the retinal surface image was extracted using KSM, and a dataset for FAZ extraction was created. Based on that dataset, we conducted a training test using a typical U-Net. Two examiners manually extracted the FAZ of the test data, and the results were used as gold standards to compare the Jaccard coefficients between examiners, and between each examiner and the U-Net. The Jaccard coefficient was 0.931 between examiner 1 and examiner 2, 0.951 between examiner 1 and the U-Net, and 0.933 between examiner 2 and the U-Net. The Jaccard coefficients were significantly better between examiner 1 and the U-Net than between examiner 1 and examiner 2 (p < 0.001). These data indicated that the dataset generated by KSM was as good as, if not better than, the agreement between examiners using the manual method. KSM may contribute to reducing the burden of annotation in deep learning.