YCYunzhi Chen

Yunzhi Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yunzhi Chen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Interplay Between Energy Storage and Transmission in U.S. Electricity System Expansion Planning

    by Yunzhi Chen, Wesley Cole, Brian Sergi

    As the U.S. electricity generation mix evolves and load growth accelerates, both energy storage and transmission become increasingly important sources of system flexibility and efficiency. However, their interaction is not well understood, especially for large, diverse regions. This study uses the Regional Energy Deployment System (ReEDS™) model to examine the joint planning of short-duration energy storage, long-duration energy storage, intrazonal transmission, and interzonal transmission in a modeled future U.S. electricity system. We apply cost multipliers to each storage and transmission type and evaluate 125 model cases across five scenarios representing different demand and technology futures. The results show storage and transmission are neither independent nor fully interchangeable. They interact through two channels: 1) direct but partial substitution between temporal and spatial flexibility and 2) indirect interaction through the generation portfolio they enable. When interzonal transmission becomes expensive, the system substitutes away from transmission expansion toward long-duration energy storage and, to a lesser extent, short-duration energy storage; when storage is more expensive, the system leans more on interzonal transmission. Lower short-duration energy storage cost shifts the system toward a more locally balanced resource mix with greater battery and solar deployment, whereas lower transmission cost favors greater interzonal transfer and resource sharing. Intrazonal transmission strongly shapes the generation mix: When local interconnection becomes more expensive, wind and solar deployment decline and the system rely more heavily on capacity that can be added or retained near existing grid infrastructure, especially natural gas combined-cycle plants, with some increases in nuclear and deferred coal retirements. Long-duration energy storage, represented by hydrogen storage, is deployed mainly when its cost becomes very low or when interzonal transfer is constrained, and it operates as a distinctly seasonal resource. Across all scenarios, the qualitative findings are robust, with stronger responses in higher-demand and more resource-intensive futures. These results suggest future U.S. grid planning should treat storage, intrazonal transmission, and interzonal transmission as linked flexibility resources rather than separate infrastructure categories.

  • Open Access

    Cold-Flow Properties of Estolides: The Older (D97 and D2500) versus the Mini-(D5773 and D5949) Methods

    by Grigor B. Bantchev, Helen Ngo, Yunzhi Chen, DeMichael D. Winfield, Steven C. Cermak

    There is growing research on developing new and sustainable lubricants. Sustainable lubricants with adequate cold-flow properties are of particular interest for many applications. One limitation of the established methods for measuring cold flow properties is the large volume needed to test samples. This makes initial screening of many hard-to-synthesize samples difficult. In the current study, we compared the results of the older, widely accepted ASTM methods D97 (pour point, PP) and D2500 (cloud point, CP) to the newer, smaller-volume, and easier-to-perform methods D5949 and D5773 for bio-based base oils (estolides and iso-estolides). The CP results were in good agreement for less colored samples, but D5773 gave lower values for some darker (Gardner color >8) samples, especially esters. The D5949 showed a tendency to report slightly higher PP, especially for the lower values. Viscosities and densities in a wide temperature range (15 to 120 °C) were also measured. The surface tensions were estimated by a literature group method. Viscosity and density effects can only partially explain the differences in the PP values from the two methods. In conclusion, the newer mini-methods are an acceptable substitution when larger volumes are not accessible, unless the sample is too dark.