Hidekazu Miyahara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hidekazu Miyahara has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Akitoshi Okino
FIRST, Institute of Biomedical Engineering, Institute of Science Tokyo, J2-32, 4259 Nagatsuta, Midori, Yokohama 226-8501, Japan
3 shared publications - Daisuke Ogasawara
Laboratory for Future Interdisciplinary Research of Science and Technology, Tokyo Institute of Technology, Yokohama 226-8502, Kanagawa, Japan
1 shared publication - Kaori Shigeta
BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter Str. 11, Berlin, Germany
1 shared publication - Osamu Fujita
Hokkaido University
1 shared publication Takahiro Iwai
Department of Energy Sciences, Tokyo Institute of Technology
1 shared publication- Takahiro Iwai
Forensic Science Group, Photon Science Research Division, RIKEN SPring-8 Center, Sayo-gun, Japan
1 shared publication
Latest Publications
- Open Access
- 29 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 444
Development of Ultrasonic Pulsed Plasma Jet Source for Remote Surface Treatment
We have developed a supersonic pulsed plasma jet device capable of long-distance and high-speed processing, and investigated its basic characteristics for surface treatment applications, mainly in the material and medical fields. The developed apparatus is equipped with a mechanism to transport active species in the plasma to the object to be treated by jetting the generated high-density plasma outward with supersonic pulse jets, which allows the gas flow velocity to increase significantly during pulse jetting compared with plasma generation. This enables the active species in the plasma to reach the treatment target before deactivation, thereby realizing surface treatment at a distance. Measurements using the Schlieren method revealed that the velocity of the jet flow reached Mach 1.7.
- 29 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 444
Open AccessDevelopment of Ultrasonic Pulsed Plasma Jet Source for Remote Surface Treatment
We have developed a supersonic pulsed plasma jet device capable of long-distance and high-speed processing, and investigated its basic characteristics for surface treatment applications, mainly in the material and medical fields. The developed apparatus is equipped with a mechanism to transport active species in the plasma to the object to be treated by jetting the generated high-density plasma outward with supersonic pulse jets, which allows the gas flow velocity to increase significantly during pulse jetting compared with plasma generation. This enables the active species in the plasma to reach the treatment target before deactivation, thereby realizing surface treatment at a distance. Measurements using the Schlieren method revealed that the velocity of the jet flow reached Mach 1.7.
- Open Access
- 10 February 2014
- Published by Springer Nature in Analytical Sciences
- Vol. 30 (2) , 231-235
A New Air-cooled Argon/Helium-compatible Inductively Coupled Plasma Torch
A new inductively coupled plasma (ICP) torch with an air-cooling system has been designed and developed for both argon and helium plasma. The same torch and impedance-matching network could be used to generate stable Ar- and He-ICP. The torch consists of three concentric quartz tubes. The carrier gas, plasma gas, and cooling gas flow through the intervals between each tube. In an experiment, it was found that Ar-ICP could form a stable plasma under the following conditions: RF power of 1 kW, plasma gas flow rate of 11 L min−1, and cooling gas flow rate of 20 L min−1. For He-ICP, an input RF power of 2 kW, which is two-times higher than that of a conventional He-ICP, could be constantly applied to the plasma with plasma gas and cooling gas flow rates of 15 and 20 L min−1, respectively. Using this torch, it is possible to realize lower plasma gas consumption for Ar- and He-ICP and a high-power drive for He-ICP. It has been found that the air-cooling gas stabilizes the shape of the plasma due to the pressure difference between the cooling gas and the plasma gas.
- 10 February 2014
- Published by Springer Nature in Analytical Sciences
- Vol. 30 (2) , 231-235
Open AccessA New Air-cooled Argon/Helium-compatible Inductively Coupled Plasma Torch
A new inductively coupled plasma (ICP) torch with an air-cooling system has been designed and developed for both argon and helium plasma. The same torch and impedance-matching network could be used to generate stable Ar- and He-ICP. The torch consists of three concentric quartz tubes. The carrier gas, plasma gas, and cooling gas flow through the intervals between each tube. In an experiment, it was found that Ar-ICP could form a stable plasma under the following conditions: RF power of 1 kW, plasma gas flow rate of 11 L min−1, and cooling gas flow rate of 20 L min−1. For He-ICP, an input RF power of 2 kW, which is two-times higher than that of a conventional He-ICP, could be constantly applied to the plasma with plasma gas and cooling gas flow rates of 15 and 20 L min−1, respectively. Using this torch, it is possible to realize lower plasma gas consumption for Ar- and He-ICP and a high-power drive for He-ICP. It has been found that the air-cooling gas stabilizes the shape of the plasma due to the pressure difference between the cooling gas and the plasma gas.
- 24 October 2013
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 29 (1) , 105-110
Development and fundamental investigation of He plasma ionization detector (HPID) for gas chromatography using DC glow discharge
In analytical chemistry, gas chromatography (GC) has been widely used because of the short measurement time and the low running costs. High-sensitivity detection is required for further improvement of the analytical performance. To date, several types of detectors have been developed. Thermal conductivity detectors (TCDs) are the most common GC detectors, and they are applicable for almost all samples. However, element-specific detection is impossible, and the limit of detection (LOD), which is on the order of 100 ppm, is not good. In this study, a new type of GC detector using atmospheric-pressure He plasma was developed. He has the highest ionization (24.58 eV) and metastable (19.82, 20.62 eV) energies among the elements. This means that He plasma can effectively ionize and excite all elements. In the helium plasma ionization detector (HPID), DC-powered He plasma and rod-like electrodes were utilized for ionization of the samples. For an ionization detector, the generation of very stable plasma is important. Therefore, we used DC He plasma. The sample was ionized when it was mixed into the He afterglow plasma. The concentration of each sample was then measured by the detection of the ion or electron current. When a 2 mL mixture of 20 ppm H2, N2, O2, CH4 and CO was introduced for GC, a LOD of 21–67 ppb was achieved. Thus, the detection ability of HPID was more than 1000 times better than that of TCD.
- 24 October 2013
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 29 (1) , 105-110
Development and fundamental investigation of He plasma ionization detector (HPID) for gas chromatography using DC glow discharge
In analytical chemistry, gas chromatography (GC) has been widely used because of the short measurement time and the low running costs. High-sensitivity detection is required for further improvement of the analytical performance. To date, several types of detectors have been developed. Thermal conductivity detectors (TCDs) are the most common GC detectors, and they are applicable for almost all samples. However, element-specific detection is impossible, and the limit of detection (LOD), which is on the order of 100 ppm, is not good. In this study, a new type of GC detector using atmospheric-pressure He plasma was developed. He has the highest ionization (24.58 eV) and metastable (19.82, 20.62 eV) energies among the elements. This means that He plasma can effectively ionize and excite all elements. In the helium plasma ionization detector (HPID), DC-powered He plasma and rod-like electrodes were utilized for ionization of the samples. For an ionization detector, the generation of very stable plasma is important. Therefore, we used DC He plasma. The sample was ionized when it was mixed into the He afterglow plasma. The concentration of each sample was then measured by the detection of the ion or electron current. When a 2 mL mixture of 20 ppm H2, N2, O2, CH4 and CO was introduced for GC, a LOD of 21–67 ppb was achieved. Thus, the detection ability of HPID was more than 1000 times better than that of TCD.