Yixuan Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yixuan Wu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Luca Peretti
KTH Royal Institute of Technology, Stockholm, Sweden
13 shared publications - Gustaf Falk Olson
Division of Electric Power and Energy Systems, KTH Royal Institute of Technology, Stockholm, Sweden
6 shared publications - Luca Vancini
University of Bologna
3 shared publications - Luca Zarri
Department of Electrical, Electronic, and Information Engineering Guglielmo Marconi, University of Bologna, Bologna, Italy
3 shared publications - Omer Ikram Ul Haq
Department of Energy Conversion, ABB Corporate Research, Vsters, Sweden
3 shared publications - Michele Mengoni
University of Bologna
2 shared publications
Latest Publications
- Open Access
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 267-280
A Variable Frequency Technique for EMI and Efficiency Improvements in High-Level Count Flying Capacitor Multilevel Converters
This work proposes a variable switching frequency scheme for a flying capacitor multilevel (FCML) converter in dc-ac operation to better utilize the output inductor for its rated peak-to-peak current ripple and substantially reduce converter losses over the ac modulation cycle. The proposed technique holds the inductor current ripple constant by leveraging the duty-cycle-dependent inductor current ripple and varies the switching frequency to hold this current ripple constant at its rated design value. Furthermore, this technique can be leveraged to spread conducted electromagnetic interference peaks at both the input and output ports of the inverter. Practical lower switching limits are derived and taken into consideration in developing this approach, and experimental results validate the feasibility in a common microcontroller framework. Hardware results are provided for both 6-level and 8-level FCML inverters and showcase loss reductions and improved electromagnetic interference performance.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 267-280
Open AccessA Variable Frequency Technique for EMI and Efficiency Improvements in High-Level Count Flying Capacitor Multilevel Converters
This work proposes a variable switching frequency scheme for a flying capacitor multilevel (FCML) converter in dc-ac operation to better utilize the output inductor for its rated peak-to-peak current ripple and substantially reduce converter losses over the ac modulation cycle. The proposed technique holds the inductor current ripple constant by leveraging the duty-cycle-dependent inductor current ripple and varies the switching frequency to hold this current ripple constant at its rated design value. Furthermore, this technique can be leveraged to spread conducted electromagnetic interference peaks at both the input and output ports of the inverter. Practical lower switching limits are derived and taken into consideration in developing this approach, and experimental results validate the feasibility in a common microcontroller framework. Hardware results are provided for both 6-level and 8-level FCML inverters and showcase loss reductions and improved electromagnetic interference performance.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 129-138
Low-Frequency Current Injection for Sensorless Control of Multiphase Induction Machines at Zero and Very Low Speeds
This article introduces a sensorless control strategy for a seven-phase induction motor drive, leveraging the inherent degrees of freedom in multiphase systems. The proposed approach relies on injecting a low-frequency current to excite the third spatial harmonic of the magnetic field in the air gap. This excitation facilitates the estimation of the third spatial harmonic component of the flux linkage. The injection of a low-frequency current enables the estimation of the rotor flux position at zero and very low speeds without torque ripple, which is an essential requirement for the reliable operation of sensorless drives. The experimental tests conducted under different operating conditions confirm the robustness of the proposed solution, as well as its dynamic response and stable behavior at zero and low speeds.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 129-138
Low-Frequency Current Injection for Sensorless Control of Multiphase Induction Machines at Zero and Very Low Speeds
This article introduces a sensorless control strategy for a seven-phase induction motor drive, leveraging the inherent degrees of freedom in multiphase systems. The proposed approach relies on injecting a low-frequency current to excite the third spatial harmonic of the magnetic field in the air gap. This excitation facilitates the estimation of the third spatial harmonic component of the flux linkage. The injection of a low-frequency current enables the estimation of the rotor flux position at zero and very low speeds without torque ripple, which is an essential requirement for the reliable operation of sensorless drives. The experimental tests conducted under different operating conditions confirm the robustness of the proposed solution, as well as its dynamic response and stable behavior at zero and low speeds.
- 17 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 10573-10582
Optimal Pole-Transition Current Distribution for Constant Torque Maintenance and Stator Copper Loss Minimization in Variable-Pole Machines
Variable phase-pole machines possess the capability to expand their operational range by employing magnetic pole change while adhering to the same electrical voltage and current limits. This article proposes a strategy to achieve a pole change with constant torque while simultaneously optimizing current distributions for stator copper loss minimization. The overall outcome is the ability to facilitate smooth $dq0$ current transitions while reducing the energy consumption of variable phase-pole machine drives. Experimental results affirm the efficacy of this approach during the pole change process.
- 17 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 10573-10582
Optimal Pole-Transition Current Distribution for Constant Torque Maintenance and Stator Copper Loss Minimization in Variable-Pole Machines
Variable phase-pole machines possess the capability to expand their operational range by employing magnetic pole change while adhering to the same electrical voltage and current limits. This article proposes a strategy to achieve a pole change with constant torque while simultaneously optimizing current distributions for stator copper loss minimization. The overall outcome is the ability to facilitate smooth $dq0$ current transitions while reducing the energy consumption of variable phase-pole machine drives. Experimental results affirm the efficacy of this approach during the pole change process.
- Open Access
- 27 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 185250-185264
Multiphase Machines: Stator and Rotor Inter-Plane Cross Saturation
Multiphase induction machines are investigated as competitive magnet-free candidates for high torque-density, overload-capable, and wide torque-speed range applications. These benefits are enabled by torque-enhancing harmonic injection and phase-pole changes. However, such operational modes may subject the different harmonic planes to cross-saturation. Consequently, a well-performing drive requires an accurate model. This paper models the inter-plane cross saturation between the excited harmonic planes in the main flux path and the rotor slot-bridges. It is valid even for unsynchronized harmonic magnetic fields manifesting themselves during current control as low-frequency beats in the voltage amplitude. An advanced Γ-model also including the skin effect of the rotor is proposed and validated against experiments. The results indicate that the proposed model represents the behavior of a 15-kW variable phase-pole machine more accurately than a constant parameter Γ-model. This warrants better field orientation and torque output predictions in future drives.
- 27 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 185250-185264
Open AccessMultiphase Machines: Stator and Rotor Inter-Plane Cross Saturation
Multiphase induction machines are investigated as competitive magnet-free candidates for high torque-density, overload-capable, and wide torque-speed range applications. These benefits are enabled by torque-enhancing harmonic injection and phase-pole changes. However, such operational modes may subject the different harmonic planes to cross-saturation. Consequently, a well-performing drive requires an accurate model. This paper models the inter-plane cross saturation between the excited harmonic planes in the main flux path and the rotor slot-bridges. It is valid even for unsynchronized harmonic magnetic fields manifesting themselves during current control as low-frequency beats in the voltage amplitude. An advanced Γ-model also including the skin effect of the rotor is proposed and validated against experiments. The results indicate that the proposed model represents the behavior of a 15-kW variable phase-pole machine more accurately than a constant parameter Γ-model. This warrants better field orientation and torque output predictions in future drives.
- 1 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1411-1421
Minimum Torque Dip Pole Transition in Variable Phase-Pole Machines With Voltage Limitation
Induction machine-based multiphase electrical machines combine the robustness and reliability of well-known induction machines with the benefits of additional degrees of freedom, such as potential higher torque density and true fault tolerance. The subcategory of variable phase-pole machines allows extending the operational torque and speed range with the same voltage and current limits by changing the number of magnetic poles through control without hardware reconfiguration. Maintaining the torque throughout the operation is vital for many applications. The question of maintaining torque during a pole transition still needs to be answered, especially concerning the electric limitations. This paper's proposed pole transition strategy minimizes the torque dip during the pole transition. Field weakening is added to the control scheme to accommodate the voltage limitation. Experimentally controlled, loaded, and scheduled pole transitions demonstrate the capabilities of the proposed strategy with and without voltage limitation.
- 1 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1411-1421
Minimum Torque Dip Pole Transition in Variable Phase-Pole Machines With Voltage Limitation
Induction machine-based multiphase electrical machines combine the robustness and reliability of well-known induction machines with the benefits of additional degrees of freedom, such as potential higher torque density and true fault tolerance. The subcategory of variable phase-pole machines allows extending the operational torque and speed range with the same voltage and current limits by changing the number of magnetic poles through control without hardware reconfiguration. Maintaining the torque throughout the operation is vital for many applications. The question of maintaining torque during a pole transition still needs to be answered, especially concerning the electric limitations. This paper's proposed pole transition strategy minimizes the torque dip during the pole transition. Field weakening is added to the control scheme to accommodate the voltage limitation. Experimentally controlled, loaded, and scheduled pole transitions demonstrate the capabilities of the proposed strategy with and without voltage limitation.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 4364-4374
Combined Reduction of DC-link Harmonics and Common Mode Voltage in Interleaved Multi-inverter Systems by Modified SVPWM Schemes
DC-link current harmonics and common mode voltage (CMV) are key design challenges for inverter-based power electronic systems. Addressing them collectively without additional hardware and/or complexity has promising advantages. This article investigates the interleaved utilization of modified space vector PWM schemes for parallel-inverter systems, targeting a combined and simultaneous reduction of these quality concerns. A time-domain analytical dc-link current formulation and a new application of sequence-based interleaving are combined in an offline numerical optimization algorithm that locates optimal interleaving shifts synced with the PWM sequence. With simulation and experimental validation, the corresponding numerical results ascertain an effective suppression of dc-link current harmonics alongside CMV reduction. In addition, this article extends the proposed idea to a special application for 3xmultiphase machines through experimental validation.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 4364-4374
Combined Reduction of DC-link Harmonics and Common Mode Voltage in Interleaved Multi-inverter Systems by Modified SVPWM Schemes
DC-link current harmonics and common mode voltage (CMV) are key design challenges for inverter-based power electronic systems. Addressing them collectively without additional hardware and/or complexity has promising advantages. This article investigates the interleaved utilization of modified space vector PWM schemes for parallel-inverter systems, targeting a combined and simultaneous reduction of these quality concerns. A time-domain analytical dc-link current formulation and a new application of sequence-based interleaving are combined in an offline numerical optimization algorithm that locates optimal interleaving shifts synced with the PWM sequence. With simulation and experimental validation, the corresponding numerical results ascertain an effective suppression of dc-link current harmonics alongside CMV reduction. In addition, this article extends the proposed idea to a special application for 3xmultiphase machines through experimental validation.
- 1 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sensorless Control with Indirect Field Oriented Speed Estimation for Seven-Phase Induction Machines
Multiphase machines offer more degrees of freedom than conventional three-phase machines. Thus, a multiphase drive can control multiple spatial harmonics independently of each other. With the torque generation in the 1 st vector space, this paper proposes to inject currents in the $3^{rd}$ vector space for the speed estimation thus realizing a sensorless control scheme. At lower mechanical speeds, the back-EMF decreases and becomes more difficult to estimate as the signal-to-noise ratio decreases. Injecting a slip increases the stator frequency, which in turn allows a better estimation of the back electromotive force. An experiment showing a start from standstill conditions demonstrates the proposed control.- 1 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sensorless Control with Indirect Field Oriented Speed Estimation for Seven-Phase Induction Machines
Multiphase machines offer more degrees of freedom than conventional three-phase machines. Thus, a multiphase drive can control multiple spatial harmonics independently of each other. With the torque generation in the 1 st vector space, this paper proposes to inject currents in the $3^{rd}$ vector space for the speed estimation thus realizing a sensorless control scheme. At lower mechanical speeds, the back-EMF decreases and becomes more difficult to estimate as the signal-to-noise ratio decreases. Injecting a slip increases the stator frequency, which in turn allows a better estimation of the back electromotive force. An experiment showing a start from standstill conditions demonstrates the proposed control.- Open Access
- 3 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (4) , 3765-3774
Open-Phase Fault-Tolerant Pole Transition Control of an Asynchronous Variable-Pole Machine Using Harmonic Plane Decomposition
Automotive applications are revisiting the use of induction machines as magnet-free propulsive solutions due to their intrinsic robustness and reliability. Special multiphase configurations are under investigation to reduce the losses further and fulfill the stringent energy-efficiency and compactness requirements of the automotive industry. One of these configurations is known as variable-pole machines, which allows the number of magnetic pole pairs to change on the fly. These machines can stretch the torque-speed operating region, exploit the maximum torque capability, and exhibit competitive efficiency. Although fault tolerance has been widely explored for multiphase machines, the same cannot be said for variable-pole machines because, until recently, complete models to describe their dynamics under any condition, including magnetic pole changing and fault occurrences, were unavailable. This paper presents a post-fault control strategy for variable-pole machines with an open-phase fault, which can operate during pole changing and addresses the issue of fault-tolerant operation. The effectiveness of the control system is verified by experimental tests carried out with an eighteen-phase variable-pole induction machine prototype.
- 3 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (4) , 3765-3774
Open AccessOpen-Phase Fault-Tolerant Pole Transition Control of an Asynchronous Variable-Pole Machine Using Harmonic Plane Decomposition
Automotive applications are revisiting the use of induction machines as magnet-free propulsive solutions due to their intrinsic robustness and reliability. Special multiphase configurations are under investigation to reduce the losses further and fulfill the stringent energy-efficiency and compactness requirements of the automotive industry. One of these configurations is known as variable-pole machines, which allows the number of magnetic pole pairs to change on the fly. These machines can stretch the torque-speed operating region, exploit the maximum torque capability, and exhibit competitive efficiency. Although fault tolerance has been widely explored for multiphase machines, the same cannot be said for variable-pole machines because, until recently, complete models to describe their dynamics under any condition, including magnetic pole changing and fault occurrences, were unavailable. This paper presents a post-fault control strategy for variable-pole machines with an open-phase fault, which can operate during pole changing and addresses the issue of fault-tolerant operation. The effectiveness of the control system is verified by experimental tests carried out with an eighteen-phase variable-pole induction machine prototype.
- Open Access
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 40049-40063
Enabling Variable Phase-Pole Drives With the Harmonic Plane Decomposition
Magnet-free variable phase-pole machines are competitive alternatives in electric vehicles where torque-speed operating region, reliability, cost, and energy efficiency are key metrics. However, their modeling and control have so far relied on existing fixed-phase and pole-symmetrical models, limiting their drive capabilities especially when switching the number of poles on the fly. This paper establishes the harmonic plane decomposition theory as a space-discrete Fourier transformation interpretation of the Clarke transformation, decomposing all pole-pair fields into a fixed number of orthogonal subspaces with invariant parameters. The model remains unaltered for all phase-pole configurations, guaranteeing continuity even under phase-pole transitions. Relations of the state and input space vectors, and model parameters to those of the vector space decomposition theory used for multiphase machines are established via the use of the complex winding factor. Experiments confirm the modeling theory and demonstrate its practical usefulness by performing a field-oriented-controlled phase-pole transition. Non-trivial configurations with more than one slot/pole/phase and a fractional phase number are also demonstrated.
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 40049-40063
Open AccessEnabling Variable Phase-Pole Drives With the Harmonic Plane Decomposition
Magnet-free variable phase-pole machines are competitive alternatives in electric vehicles where torque-speed operating region, reliability, cost, and energy efficiency are key metrics. However, their modeling and control have so far relied on existing fixed-phase and pole-symmetrical models, limiting their drive capabilities especially when switching the number of poles on the fly. This paper establishes the harmonic plane decomposition theory as a space-discrete Fourier transformation interpretation of the Clarke transformation, decomposing all pole-pair fields into a fixed number of orthogonal subspaces with invariant parameters. The model remains unaltered for all phase-pole configurations, guaranteeing continuity even under phase-pole transitions. Relations of the state and input space vectors, and model parameters to those of the vector space decomposition theory used for multiphase machines are established via the use of the complex winding factor. Experiments confirm the modeling theory and demonstrate its practical usefulness by performing a field-oriented-controlled phase-pole transition. Non-trivial configurations with more than one slot/pole/phase and a fractional phase number are also demonstrated.
- 1 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (4) , 4557-4566
Open Fault Detection in Variable Phase-Pole Machines Based on Harmonic Plane Decomposition
Multiphase electrical machines are inherently fault tolerant due to the higher number of phases. An important step in achieving a fault tolerant control is the ability to detect and identify the fault. In variable phase-pole drives, which are a class of multiphase machines that change the number of pole pairs during real-time operation, there are further unexplored possibilities. Based on the harmonic plane decomposition theory for variable phase-pole machines, a fault detection and identification algorithm is proposed, which analyzes the spatial harmonics of the current distribution. The fault detection is fast, operation independent, non-invasive, parameter-insensitive, and computationally simple. Experimental tests validate the proposed method.
- 1 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (4) , 4557-4566
Open Fault Detection in Variable Phase-Pole Machines Based on Harmonic Plane Decomposition
Multiphase electrical machines are inherently fault tolerant due to the higher number of phases. An important step in achieving a fault tolerant control is the ability to detect and identify the fault. In variable phase-pole drives, which are a class of multiphase machines that change the number of pole pairs during real-time operation, there are further unexplored possibilities. Based on the harmonic plane decomposition theory for variable phase-pole machines, a fault detection and identification algorithm is proposed, which analyzes the spatial harmonics of the current distribution. The fault detection is fast, operation independent, non-invasive, parameter-insensitive, and computationally simple. Experimental tests validate the proposed method.