Anurag Tewari
Anurag Tewari has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Abara A. Biabak Indrick
School of Environmental Studies, China University of Geosciences, Wuhan 430074, China
1 shared publication - G.O. Obaiah
Department of Chemistry, Karnataka State Open University, Mukhtagangotri, Mysuru-570006, India
1 shared publication - Hafizou M. Sow
School of Environmental Studies, China University of Geosciences, Wuhan 430074, China
1 shared publication - Milind Shamrao Thakare
Department of Chemistry, Pratap College (Autonomous), Amalner-425401, India
1 shared publication - Mohamed Hussein Yousif
School of Environmental Studies, China University of Geosciences, Wuhan 430074, China
1 shared publication - Mohammed Alaa Abdulzahra
Факультет фармації, Коледж спеціалізованих медичних наук Аль-Амал
1 shared publication
Latest Publications
- Open Access
An Explainable Artificial Intelligence-Driven Framework for Predicting Groundwater Irrigation Suitability in Hard-Rock Aquifers: Moving Beyond Traditional Bivariate Diagnostics
Groundwater is the primary source of irrigation in many semi-arid hard-rock aquifer regions. Yet, its suitability assessment is often hindered by the nonlinear hydrochemical dynamics that traditional bivariate tools, such as the U.S. Salinity Laboratory (USSL) diagram, cannot adequately resolve. To overcome this limitation, we developed an explainable artificial intelligence (XAI) framework that predicts irrigation suitability categories directly from hydrochemical variables, without relying on calculated indices. Using 1872 post-monsoon groundwater samples from Telangana, India, we trained three ensemble tree-based classifiers (Random Forest, LightGBM, and XGBoost) on 11 hydrochemical variables (Na+, K+, Ca2+, Mg2+, HCO3−, Cl−, F−, NO3−, SO42−, pH, and total hardness). Class imbalance was addressed using the Synthetic Minority Over-sampling Technique (SMOTE), and model hyperparameters were optimized with Optuna. Among the tested models, LightGBM achieved the best performance (balanced accuracy = 0.938). Model interpretability was enabled using Shapley Additive Explanations (SHAP), supported by Piper and Gibbs diagrams, revealing a critical distinction between sodicity-driven salinity and hardness-driven mineralization, identifying calcium-saturated waters for which gypsum amendment can be chemically futile. To bridge the gap between algorithmic accuracy and operational simplicity, we distilled SHAP explanations into linear heuristics and quantified the trade-off between accuracy and simplicity. Accordingly, we proposed a tiered hydrochemical triage framework in which quantitative heuristics handled approximately 62.5% of the routine samples, while XAI resolved the complex and ambiguous cases. Overall, the proposed framework transforms classic suitability assessment tools into an adaptable, evidence-informed, proactive decision-support system for sustainable agricultural water management under increasing environmental stress.
Open AccessAn Explainable Artificial Intelligence-Driven Framework for Predicting Groundwater Irrigation Suitability in Hard-Rock Aquifers: Moving Beyond Traditional Bivariate Diagnostics
Groundwater is the primary source of irrigation in many semi-arid hard-rock aquifer regions. Yet, its suitability assessment is often hindered by the nonlinear hydrochemical dynamics that traditional bivariate tools, such as the U.S. Salinity Laboratory (USSL) diagram, cannot adequately resolve. To overcome this limitation, we developed an explainable artificial intelligence (XAI) framework that predicts irrigation suitability categories directly from hydrochemical variables, without relying on calculated indices. Using 1872 post-monsoon groundwater samples from Telangana, India, we trained three ensemble tree-based classifiers (Random Forest, LightGBM, and XGBoost) on 11 hydrochemical variables (Na+, K+, Ca2+, Mg2+, HCO3−, Cl−, F−, NO3−, SO42−, pH, and total hardness). Class imbalance was addressed using the Synthetic Minority Over-sampling Technique (SMOTE), and model hyperparameters were optimized with Optuna. Among the tested models, LightGBM achieved the best performance (balanced accuracy = 0.938). Model interpretability was enabled using Shapley Additive Explanations (SHAP), supported by Piper and Gibbs diagrams, revealing a critical distinction between sodicity-driven salinity and hardness-driven mineralization, identifying calcium-saturated waters for which gypsum amendment can be chemically futile. To bridge the gap between algorithmic accuracy and operational simplicity, we distilled SHAP explanations into linear heuristics and quantified the trade-off between accuracy and simplicity. Accordingly, we proposed a tiered hydrochemical triage framework in which quantitative heuristics handled approximately 62.5% of the routine samples, while XAI resolved the complex and ambiguous cases. Overall, the proposed framework transforms classic suitability assessment tools into an adaptable, evidence-informed, proactive decision-support system for sustainable agricultural water management under increasing environmental stress.
- Open Access
- 29 June 2024
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 36 (7) , 1571-1578
Selective Sensing and Determination of Cu2+ Ions in Environmental Samples with Newly Prepared Quinoline based Chemosensors and Confirmation of Results using DFT Molecular Modelling
An efficient turn-off-fluorescence chemosensing method has been developed to detect Cu2+ ions in a variety of samples. Two new quinoline-based chemosensors (QC1 and QC2) have been prepared under the condensation reaction of 8-quinolinecarboxylic acid with derivatives of L-valine. The synthesized chemosensors were characterized by spectroscopic techniques such as 1H NMR, UV, IR, HRMS and CHNS. The HOMO-LUMO orbitals and energy-minimized structures of the chemosensors were developed. The interaction of metal ions with chemosensors and stable structures of complexes were investigated using DFT. The photoluminescence analysis of both chemosensors (QC1 and QC2) showed the fluorescence emission wavelengths on 495 and 512 nm, respectively, for QC1 and QC2. The change in fluorescence emission wavelengths depends on the electronic effects of the substituents on the quinoline ring. The chemosensors showed a high sensitivity for Cu ions; thus, the detection was exhibited in nanomolar levels. The chemosensing studies were performed in the presence of different metal ions and samples taken from other sources.
- 29 June 2024
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 36 (7) , 1571-1578
Open AccessSelective Sensing and Determination of Cu2+ Ions in Environmental Samples with Newly Prepared Quinoline based Chemosensors and Confirmation of Results using DFT Molecular Modelling
An efficient turn-off-fluorescence chemosensing method has been developed to detect Cu2+ ions in a variety of samples. Two new quinoline-based chemosensors (QC1 and QC2) have been prepared under the condensation reaction of 8-quinolinecarboxylic acid with derivatives of L-valine. The synthesized chemosensors were characterized by spectroscopic techniques such as 1H NMR, UV, IR, HRMS and CHNS. The HOMO-LUMO orbitals and energy-minimized structures of the chemosensors were developed. The interaction of metal ions with chemosensors and stable structures of complexes were investigated using DFT. The photoluminescence analysis of both chemosensors (QC1 and QC2) showed the fluorescence emission wavelengths on 495 and 512 nm, respectively, for QC1 and QC2. The change in fluorescence emission wavelengths depends on the electronic effects of the substituents on the quinoline ring. The chemosensors showed a high sensitivity for Cu ions; thus, the detection was exhibited in nanomolar levels. The chemosensing studies were performed in the presence of different metal ions and samples taken from other sources.
- Open Access
- 30 December 2022
- Published by Oriental Scientific Publishing Company in Oriental Journal of Chemistry
- Vol. 38 (6) , 1428-1434
Studies on Polymeric hydroxy Compounds and Electro-coagulation Process for Removing Arsenic from ground water
This paper describes observations made on studies carried in laboratory trials by using electro-coagulation process using iron electrodes. The purpose of this study is to present the iron electrode-based EC procedure, its superiority over other technologies used for removing arsenic from ground water and surface water. In order to reduce arsenic (As), it was also necessary to understand the basics of the electrochemical process (EC) and the significance of its operating conditions, such as anode materials, applied voltage, pH and anode distance. At different concentration of Arsenic (500ppb, 200ppb & 100 ppb) it was observed that with the higher concentration i.e. 500 ppb there is faster decrease in arsenic concentration at 6.5 pH. While, when using different current density 0.5 A & 1.0 A at (12V) almost same results were obtained i.e. arsenic removal took place in same time duration at a pH range of 3.5 to 6.5. It was also observed that arsenic concentration decreases with electrode spacing, size of electrodes and contact time of treatment.
- 30 December 2022
- Published by Oriental Scientific Publishing Company in Oriental Journal of Chemistry
- Vol. 38 (6) , 1428-1434
Open AccessStudies on Polymeric hydroxy Compounds and Electro-coagulation Process for Removing Arsenic from ground water
This paper describes observations made on studies carried in laboratory trials by using electro-coagulation process using iron electrodes. The purpose of this study is to present the iron electrode-based EC procedure, its superiority over other technologies used for removing arsenic from ground water and surface water. In order to reduce arsenic (As), it was also necessary to understand the basics of the electrochemical process (EC) and the significance of its operating conditions, such as anode materials, applied voltage, pH and anode distance. At different concentration of Arsenic (500ppb, 200ppb & 100 ppb) it was observed that with the higher concentration i.e. 500 ppb there is faster decrease in arsenic concentration at 6.5 pH. While, when using different current density 0.5 A & 1.0 A at (12V) almost same results were obtained i.e. arsenic removal took place in same time duration at a pH range of 3.5 to 6.5. It was also observed that arsenic concentration decreases with electrode spacing, size of electrodes and contact time of treatment.