Wirachai Roynarin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wirachai Roynarin has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Dongmyoung Kim
Department of Integrated Energy and Infra System, Kangwon National University, Chuncheon-si 24341, Gangwon, Republic of Korea
3 shared publications - Insu Paek
Kangwon National University
3 shared publications - Taesu Jeon
Department of Integrated Energy and Infra System, Kangwon National University, Chuncheon-si 24341, Gangwon, Republic of Korea
2 shared publications - Amphol Aphathanakorn
National Innovation Agency, 73/2 Rama VI Road, Rajdhevee, Bangkok 10400, Thailand
1 shared publication - Bayasgalan Dugarjav
Department of Green Energy and Engineering, National University of Mongolia, Ulaanbaatar 14201, Mongolia
1 shared publication - Boonyang Plangklang
Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Thanyaburi, Pathum Thani 12110, Thailand
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Energy Systems Integration
- Vol. 7 (1)
Deep Learning‐Driven Forecasting for Compressed Air Oxygenation Integrating With Floating PV Power Generation System
Insufficient dissolved oxygen in aquaculture systems poses a significant challenge to sustainable fish farming, while traditional aeration systems rely heavily on grid electricity, contributing to both operational costs and environmental impact. This study addresses these challenges by integrating a compressed air oxygenation system with floating solar photovoltaic (PV) power generation, supported by deep learning‐based forecasting for optimal system control. Our key contributions include: (1) development of an integrated floating PV‐powered compressed air oxygenation system for aquaculture, (2) implementation and comparative analysis of three deep learning models (RNN, GRU and LSTM) for forecasting both PV power generation and compressed air production and (3) validation through a real‐world case study in Thailand's Pathum Thani Province. The LSTM model demonstrated superior performance, achieving the highest accuracy with RMSE of 172.59 kW and MAPE of 13.87% for PV power forecasting, and a MAPE of 21.72% for compressed air production forecasting. The implemented system successfully improved water quality in a 1200‐cubic‐metre freshwater fish pond, increasing dissolved oxygen levels from 1.7 to 6.47 mg/L over a 4‐month period. These results demonstrate the feasibility and effectiveness of renewable energy integration in aquaculture water treatment, offering a sustainable solution for fish farming operations while reducing dependency on grid electricity.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Energy Systems Integration
- Vol. 7 (1)
Open AccessDeep Learning‐Driven Forecasting for Compressed Air Oxygenation Integrating With Floating PV Power Generation System
Insufficient dissolved oxygen in aquaculture systems poses a significant challenge to sustainable fish farming, while traditional aeration systems rely heavily on grid electricity, contributing to both operational costs and environmental impact. This study addresses these challenges by integrating a compressed air oxygenation system with floating solar photovoltaic (PV) power generation, supported by deep learning‐based forecasting for optimal system control. Our key contributions include: (1) development of an integrated floating PV‐powered compressed air oxygenation system for aquaculture, (2) implementation and comparative analysis of three deep learning models (RNN, GRU and LSTM) for forecasting both PV power generation and compressed air production and (3) validation through a real‐world case study in Thailand's Pathum Thani Province. The LSTM model demonstrated superior performance, achieving the highest accuracy with RMSE of 172.59 kW and MAPE of 13.87% for PV power forecasting, and a MAPE of 21.72% for compressed air production forecasting. The implemented system successfully improved water quality in a 1200‐cubic‐metre freshwater fish pond, increasing dissolved oxygen levels from 1.7 to 6.47 mg/L over a 4‐month period. These results demonstrate the feasibility and effectiveness of renewable energy integration in aquaculture water treatment, offering a sustainable solution for fish farming operations while reducing dependency on grid electricity.
- Open Access
- 1 January 2025
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 14 (2) , 224-232
Effects of structure height and temperature to power generation of a 4.86 kWp solar land
Efficient heat transfer significantly improves both the efficacy of photovoltaic (PV) systems and the longevity of PV panels. Lower temperatures facilitate improved power generation and minimize heat-related damage. Conduction, convection, and radiation are the primary heat transfer mechanisms that are involved in this process. This study investigated the effects of PV panel structure heights—specifically 1 meter, 1.5 meters, and 2 meters—on the temperature differences between the top and bottom of the panels, as well as their corresponding power generation, while accounting for the heat transfer that occurred. The PV system comprised nine 540-watt monocrystalline PV panels arranged at these three heights in Khlong Si, Khlong Luang, and Pathum Thani. Data on temperature, power output, and other meteorological variables were collected at 5-minute intervals from 6:00 AM to 6:00 PM over a two-month period from March to April 2024. To evaluate the impact of panel height on performance, all collected data were analyzed. The actual power outputs were compared with simulations conducted using PVsyst. Additionally, the costs associated with each panel height were assessed to identify the optimal height that would achieve both high power output and low costs. The findings revealed that increasing the panel height contributed to a reduction in temperature buildup within the panels and enhanced power output, with increases of 8.87% and 9.45% observed at heights of 1.5 meters and 2 meters, respectively. However, this increase in height also resulted in cost escalations of 24.51% and 48.04%, respectively. Consequently, it was determined that the optimal height was 1.5 meters, as it provided an effective balance between maximizing power output and minimizing costs. Furthermore, the results from the PVsyst simulations indicated significant discrepancies, with measured values approximately 20% lower than expected.
- 1 January 2025
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 14 (2) , 224-232
Open AccessEffects of structure height and temperature to power generation of a 4.86 kWp solar land
Efficient heat transfer significantly improves both the efficacy of photovoltaic (PV) systems and the longevity of PV panels. Lower temperatures facilitate improved power generation and minimize heat-related damage. Conduction, convection, and radiation are the primary heat transfer mechanisms that are involved in this process. This study investigated the effects of PV panel structure heights—specifically 1 meter, 1.5 meters, and 2 meters—on the temperature differences between the top and bottom of the panels, as well as their corresponding power generation, while accounting for the heat transfer that occurred. The PV system comprised nine 540-watt monocrystalline PV panels arranged at these three heights in Khlong Si, Khlong Luang, and Pathum Thani. Data on temperature, power output, and other meteorological variables were collected at 5-minute intervals from 6:00 AM to 6:00 PM over a two-month period from March to April 2024. To evaluate the impact of panel height on performance, all collected data were analyzed. The actual power outputs were compared with simulations conducted using PVsyst. Additionally, the costs associated with each panel height were assessed to identify the optimal height that would achieve both high power output and low costs. The findings revealed that increasing the panel height contributed to a reduction in temperature buildup within the panels and enhanced power output, with increases of 8.87% and 9.45% observed at heights of 1.5 meters and 2 meters, respectively. However, this increase in height also resulted in cost escalations of 24.51% and 48.04%, respectively. Consequently, it was determined that the optimal height was 1.5 meters, as it provided an effective balance between maximizing power output and minimizing costs. Furthermore, the results from the PVsyst simulations indicated significant discrepancies, with measured values approximately 20% lower than expected.
- Open Access
- 12 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11598
Performance Validation of Control Algorithm Considering Independent Generator Torque Control in PCS
This study designed and validated a power control algorithm tailored to the unique characteristics of a 100 kW wind turbine equipped with an independent generator torque control system within the Power Conversion System (PCS). Unlike conventional power control methods based on the Programmable Logic Controller (PLC), the independent generator torque control in the PCS estimates the generator speed based on the voltage signal and performs the generator torque control without any interference from the PLC. The conventional power control algorithm in the PLC was modified so that the PLC could perform the power control by the blade pitch control only. Furthermore, a mode transition algorithm was designed to improve the shortcomings of the mode switch previously used for transitioning between the torque and pitch control modes. To verify the performance, a simulation environment similar to actual control conditions was established using a commercial analysis program, and dynamic simulations were conducted. Additionally, for the experimental validation, the proposed control algorithm was applied to a scaled wind turbine, and wind tunnel tests were performed. The results of the simulations and wind tunnel tests confirmed the operational performance of the PCS’s torque control and the improved control transition logic. The proposed control algorithm could be specifically applied to medium-sized wind turbines employing a sensorless generator speed estimation method and independent generator torque control in the PCS.
- 12 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11598
Open AccessPerformance Validation of Control Algorithm Considering Independent Generator Torque Control in PCS
This study designed and validated a power control algorithm tailored to the unique characteristics of a 100 kW wind turbine equipped with an independent generator torque control system within the Power Conversion System (PCS). Unlike conventional power control methods based on the Programmable Logic Controller (PLC), the independent generator torque control in the PCS estimates the generator speed based on the voltage signal and performs the generator torque control without any interference from the PLC. The conventional power control algorithm in the PLC was modified so that the PLC could perform the power control by the blade pitch control only. Furthermore, a mode transition algorithm was designed to improve the shortcomings of the mode switch previously used for transitioning between the torque and pitch control modes. To verify the performance, a simulation environment similar to actual control conditions was established using a commercial analysis program, and dynamic simulations were conducted. Additionally, for the experimental validation, the proposed control algorithm was applied to a scaled wind turbine, and wind tunnel tests were performed. The results of the simulations and wind tunnel tests confirmed the operational performance of the PCS’s torque control and the improved control transition logic. The proposed control algorithm could be specifically applied to medium-sized wind turbines employing a sensorless generator speed estimation method and independent generator torque control in the PCS.
- Open Access
- 28 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 8764
Comparison of the Wind Speed Estimation Algorithms of Wind Turbines Using a Drive Train Model and Extended Kalman Filter
To compare and validate wind speed estimation algorithms applied to wind turbines, wind speed estimators were designed in this study, based on two methods presented in the literature, and their performance was validated using the NREL 5MW model. The first method for wind speed estimation involves a three-dimensional (3D) look-up table-based approach, constructed using drive train differential equations. The second method involves applying a continuous–discrete extended Kalman filter. To verify and compare the performance of the algorithms designed using these different methods, feed-forward control algorithms, available power estimation algorithms, and a linear quadratic regulator, based on fuzzy logic (LQRF) control algorithms, were selected and applied as verification means, using the estimated wind speed as the input. Based on the simulation results, the performance of the two methods was compared. The method using drive train differential equations demonstrated superior performance in terms of reductions in the standard deviations of rotor speed and electrical power, as well as in its prediction accuracy for the available power.
- 28 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 8764
Open AccessComparison of the Wind Speed Estimation Algorithms of Wind Turbines Using a Drive Train Model and Extended Kalman Filter
To compare and validate wind speed estimation algorithms applied to wind turbines, wind speed estimators were designed in this study, based on two methods presented in the literature, and their performance was validated using the NREL 5MW model. The first method for wind speed estimation involves a three-dimensional (3D) look-up table-based approach, constructed using drive train differential equations. The second method involves applying a continuous–discrete extended Kalman filter. To verify and compare the performance of the algorithms designed using these different methods, feed-forward control algorithms, available power estimation algorithms, and a linear quadratic regulator, based on fuzzy logic (LQRF) control algorithms, were selected and applied as verification means, using the estimated wind speed as the input. Based on the simulation results, the performance of the two methods was compared. The method using drive train differential equations demonstrated superior performance in terms of reductions in the standard deviations of rotor speed and electrical power, as well as in its prediction accuracy for the available power.
- Open Access
A Study on the Improved Power Control Algorithm for a 100 kW Wind Turbine
In this study, a power compensation control algorithm was designed and validated for commercial 100 kW medium wind turbine models for power compensation due to additional generator loss. Generally, torque control considering generator efficiency is applied to a controller of a medium wind turbine; however, a control corresponding to a decrease in generator efficiency due to the surrounding environment is not possible. There is a possibility that an additional generator loss may occur due to the surrounding environment of the wind turbine already installed, and accordingly, a power compensation control algorithm is required because power is expected to decrease. The power compensation control algorithms may be divided into three methods according to a control strategy, and three power compensation control algorithms were explained and designed. The proposed power compensation control algorithms were validated using DNV’s Bladed program. The simulation conditions were selected at an average wind speed of about 18 m/s and normal turbulence model (NTM) Class A, and the additional generator loss was assumed to be 15%. The simulation comparison showed that the original power control algorithm had a deviation of 15.00% from the rated power due to a 15% generator loss, and the designed three power compensation control algorithms had a deviation of up to 0.05%.
Open AccessA Study on the Improved Power Control Algorithm for a 100 kW Wind Turbine
In this study, a power compensation control algorithm was designed and validated for commercial 100 kW medium wind turbine models for power compensation due to additional generator loss. Generally, torque control considering generator efficiency is applied to a controller of a medium wind turbine; however, a control corresponding to a decrease in generator efficiency due to the surrounding environment is not possible. There is a possibility that an additional generator loss may occur due to the surrounding environment of the wind turbine already installed, and accordingly, a power compensation control algorithm is required because power is expected to decrease. The power compensation control algorithms may be divided into three methods according to a control strategy, and three power compensation control algorithms were explained and designed. The proposed power compensation control algorithms were validated using DNV’s Bladed program. The simulation conditions were selected at an average wind speed of about 18 m/s and normal turbulence model (NTM) Class A, and the additional generator loss was assumed to be 15%. The simulation comparison showed that the original power control algorithm had a deviation of 15.00% from the rated power due to a 15% generator loss, and the designed three power compensation control algorithms had a deviation of up to 0.05%.