Adeola Aghedo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Adeola Aghedo has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Dean R. Rusby
Lawrence Livermore National Laboratory 6 , Livermore, California 94550
6 shared publications - Alexander J. Mackinnon
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
5 shared publications - Gerald Jackson Williams
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
5 shared publications - Nuno Lemos
Lawrence Livermore National Laboratory 2 , Livermore, California 94550
5 shared publications - Shaun Kerr
Lawrence Livermore National Laboratory , Livermore, California 94550
5 shared publications - Andreas J. Kemp
Lawrence Livermore National Laboratory , Livermore, California 94550
4 shared publications
Latest Publications
- Open Access
- 27 February 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (3) , 035004
Diagnostic x-ray source using electrons produced by a 100 J-class picosecond laser *
Many laser-based high-energy-density science (HEDS) facilities have one or more short-pulse (sub- to few-picosecond) laser beams for diagnostics. For the past decade, we have been developing a novel x-ray probing capability using such picosecond lasers interacting with an underdense plasma to produce relativistic electrons. The ultimate goal of these experiments is to demonstrate a new type of x-ray backlighter using the short-pulse ARC laser at the National Ignition Facility (NIF). Before this diagnostic is fielded at the NIF, it is critical to demonstrate the viability and reproducibility of the x-ray source on comparable high-power short-pulse laser systems. We present experiments that were carried out with the OMEGA EP laser at the University of Rochester’s laboratory for laser energetics. In these experiments, high-energy electrons are produced through a combination of the self-modulation instability and direct laser acceleration in an underdense gas jet. These electrons generate directional x-rays with characteristic energies up to several tens of keV as they execute betatron motion in the ion channel, and the inverse Compton scattering process generates even harder x-rays, with characteristic photon energies of 60–240 keV. When implemented on the OMEGA EP laser(s), this x-ray source yields results that are comparable to those obtained recently on the short-pulse Titan laser at the Jupiter Laser Facility at Lawrence Livermore National Laboratory, after accounting for differences in laser energy, peak intensity, focusing f /#, and plasma source. Applications of such an x-ray source for HEDS experiments are discussed.
- 27 February 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (3) , 035004
Open AccessDiagnostic x-ray source using electrons produced by a 100 J-class picosecond laser *
Many laser-based high-energy-density science (HEDS) facilities have one or more short-pulse (sub- to few-picosecond) laser beams for diagnostics. For the past decade, we have been developing a novel x-ray probing capability using such picosecond lasers interacting with an underdense plasma to produce relativistic electrons. The ultimate goal of these experiments is to demonstrate a new type of x-ray backlighter using the short-pulse ARC laser at the National Ignition Facility (NIF). Before this diagnostic is fielded at the NIF, it is critical to demonstrate the viability and reproducibility of the x-ray source on comparable high-power short-pulse laser systems. We present experiments that were carried out with the OMEGA EP laser at the University of Rochester’s laboratory for laser energetics. In these experiments, high-energy electrons are produced through a combination of the self-modulation instability and direct laser acceleration in an underdense gas jet. These electrons generate directional x-rays with characteristic energies up to several tens of keV as they execute betatron motion in the ion channel, and the inverse Compton scattering process generates even harder x-rays, with characteristic photon energies of 60–240 keV. When implemented on the OMEGA EP laser(s), this x-ray source yields results that are comparable to those obtained recently on the short-pulse Titan laser at the Jupiter Laser Facility at Lawrence Livermore National Laboratory, after accounting for differences in laser energy, peak intensity, focusing f /#, and plasma source. Applications of such an x-ray source for HEDS experiments are discussed.
- Open Access
- 1 December 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (12)
Development and scaling of MeV x-ray radiography at NIF-ARC
We investigate the generation of MeV x-rays using the Advanced Radiography Capability laser system at the National Ignition Facility using 1, 10, and 38 ps pulse durations, with laser energies reaching up to 4 kJ and using compound parabolic concentrators. Hydrodynamic simulations using up-to-date measurements of the contrast of the ARC laser are conducted, allowing us to employ an electron scaling model that incorporates scale length and pulse duration, which aligns closely with the observed temperature distributions. Comparable x-ray sources, in terms of dose, are generated when using a 10 ps pulse duration with 2.4 kJ at ∼1.9 ± 0.4 × 1018 W/cm2 and when using a 38 ps pulse duration with 4 kJ at 9.9 ± 0.4 × 1017 W/cm2, both achieving ∼16 rad in air at 1 m for x-ray energies > 0.5 MeV. Radiographs performed on the laser “line-of-sight” show significant improvements in image quality than radiographs performed at 65 degrees to the laser axis. We verify the radiography performance using Monte Carlo Simulations.
- 1 December 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (12)
Open AccessDevelopment and scaling of MeV x-ray radiography at NIF-ARC
We investigate the generation of MeV x-rays using the Advanced Radiography Capability laser system at the National Ignition Facility using 1, 10, and 38 ps pulse durations, with laser energies reaching up to 4 kJ and using compound parabolic concentrators. Hydrodynamic simulations using up-to-date measurements of the contrast of the ARC laser are conducted, allowing us to employ an electron scaling model that incorporates scale length and pulse duration, which aligns closely with the observed temperature distributions. Comparable x-ray sources, in terms of dose, are generated when using a 10 ps pulse duration with 2.4 kJ at ∼1.9 ± 0.4 × 1018 W/cm2 and when using a 38 ps pulse duration with 4 kJ at 9.9 ± 0.4 × 1017 W/cm2, both achieving ∼16 rad in air at 1 m for x-ray energies > 0.5 MeV. Radiographs performed on the laser “line-of-sight” show significant improvements in image quality than radiographs performed at 65 degrees to the laser axis. We verify the radiography performance using Monte Carlo Simulations.
- Open Access
- 1 July 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (7)
Increased electron, positron, and x-ray production from high intensity laser interactions using micro-wire targets
We report increases in energetic electrons, positrons, and x-rays emitted from high-intensity laser interactions (1018−20 W/cm2) with structured silicon micro-wires on the surface of a 1 mm gold converter target using a 10 ps laser pulse. A total of four different wire configurations are tested, where the gaps (7–28 μm) between the wires and the thicknesses (3–6 μm) of the wires are varied, while the height remains constant (∼ 25 μm). We observe the largest enhancement in electrons, positrons, and x-rays with the sparsest wire configurations. The electron temperature (T e≈ 6 MeV) remains consistent across all shots, regardless of whether wires or planar targets are used. This suggests that the observed enhancement is due to increased laser light absorption by the accelerated electrons over a long scale length. Two-dimensional particle-in-cell simulations confirm that absorption is significantly enhanced with the wire target. Additionally, specific simulations examining laser pointing on different parts of the wire structure reveal that, while the final electron spectrum remains largely insensitive, the angular distribution is highly sensitive to these variations.
- 1 July 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (7)
Open AccessIncreased electron, positron, and x-ray production from high intensity laser interactions using micro-wire targets
We report increases in energetic electrons, positrons, and x-rays emitted from high-intensity laser interactions (1018−20 W/cm2) with structured silicon micro-wires on the surface of a 1 mm gold converter target using a 10 ps laser pulse. A total of four different wire configurations are tested, where the gaps (7–28 μm) between the wires and the thicknesses (3–6 μm) of the wires are varied, while the height remains constant (∼ 25 μm). We observe the largest enhancement in electrons, positrons, and x-rays with the sparsest wire configurations. The electron temperature (T e≈ 6 MeV) remains consistent across all shots, regardless of whether wires or planar targets are used. This suggests that the observed enhancement is due to increased laser light absorption by the accelerated electrons over a long scale length. Two-dimensional particle-in-cell simulations confirm that absorption is significantly enhanced with the wire target. Additionally, specific simulations examining laser pointing on different parts of the wire structure reveal that, while the final electron spectrum remains largely insensitive, the angular distribution is highly sensitive to these variations.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Diagnostic development and needs for laser driven MeV x-ray radiography
Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Diagnostic development and needs for laser driven MeV x-ray radiography
Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.
- Open Access
- 1 July 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (7)
Source size of x rays from self-modulated laser wakefield accelerators
A comparative study of x-ray sources generated with different mechanisms from self-modulated laser wakefield acceleration (SM-LWFA) electrons was performed to compare the source size or spatial resolution for use in high energy density science applications. We examine the source size of betatron, inverse Compton scattering, and bremsstrahlung radiation with a Fresnel diffraction based formalism and a modified x-ray ray tracing model. We observe the dependence of source size on the radiation generation process, laser parameters, and compare to what is possible in other regimes of LWFA, as well as current methods. This information is significant as we begin to explore the use of light sources driven by SM-LWFA for use as a diagnostic at large-scale laser facilities where blowout regime LWFA is not possible.
- 1 July 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (7)
Open AccessSource size of x rays from self-modulated laser wakefield accelerators
A comparative study of x-ray sources generated with different mechanisms from self-modulated laser wakefield acceleration (SM-LWFA) electrons was performed to compare the source size or spatial resolution for use in high energy density science applications. We examine the source size of betatron, inverse Compton scattering, and bremsstrahlung radiation with a Fresnel diffraction based formalism and a modified x-ray ray tracing model. We observe the dependence of source size on the radiation generation process, laser parameters, and compare to what is possible in other regimes of LWFA, as well as current methods. This information is significant as we begin to explore the use of light sources driven by SM-LWFA for use as a diagnostic at large-scale laser facilities where blowout regime LWFA is not possible.
- Open Access
- 1 February 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (2)
Enhanced electron acceleration by high-intensity lasers in extended (confined) preplasma in cone targets
We report on experimental results from a high-intensity laser interaction with cone targets that increase the number (×3) and temperature (×3) of the measured hot electrons over a traditional planar target. This increase is caused by a substantial increase in the plasma density within the cone target geometry, which was induced by 17 ± 9 mJ prepulse that arrived 1.5 ns prior to the main high intensity (>1019 W/cm2). Three-dimensional hydrodynamic simulations are conducted using hydra which show that the cone targets create substantially longer and denser plasma than planar targets due to the geometric confinement of the expanding plasma. The density within the cone is a several hundred-micron plasma “shelf” with a density of approximately 1020 ne/cc. The hydra simulated plasma densities are used as the initial conditions for two-dimensional particle-in-cell simulations using EPOCH. These simulations show that the main acceleration mechanism is direct-laser-acceleration, with close agreement between experimentally measured and simulated electron temperatures. Further analysis is conducted to investigate the acceleration of the electrons within the long plasma generated within a compound parabolic concentrator by the prepulse.
- 1 February 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (2)
Open AccessEnhanced electron acceleration by high-intensity lasers in extended (confined) preplasma in cone targets
We report on experimental results from a high-intensity laser interaction with cone targets that increase the number (×3) and temperature (×3) of the measured hot electrons over a traditional planar target. This increase is caused by a substantial increase in the plasma density within the cone target geometry, which was induced by 17 ± 9 mJ prepulse that arrived 1.5 ns prior to the main high intensity (>1019 W/cm2). Three-dimensional hydrodynamic simulations are conducted using hydra which show that the cone targets create substantially longer and denser plasma than planar targets due to the geometric confinement of the expanding plasma. The density within the cone is a several hundred-micron plasma “shelf” with a density of approximately 1020 ne/cc. The hydra simulated plasma densities are used as the initial conditions for two-dimensional particle-in-cell simulations using EPOCH. These simulations show that the main acceleration mechanism is direct-laser-acceleration, with close agreement between experimentally measured and simulated electron temperatures. Further analysis is conducted to investigate the acceleration of the electrons within the long plasma generated within a compound parabolic concentrator by the prepulse.
- Open Access
- 1 January 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (1)
Development of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser
Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for Ephoton=0.5–30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at Ilaser≈2×1018 W/cm2 with CPCs is observed, with doses of >10 rad in air at 1 m for Ephoton>0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. These results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.
- 1 January 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (1)
Open AccessDevelopment of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser
Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for Ephoton=0.5–30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at Ilaser≈2×1018 W/cm2 with CPCs is observed, with doses of >10 rad in air at 1 m for Ephoton>0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. These results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.