B. Golick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
B. Golick has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
A. C. Carpenter
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
3 shared publications- A. M. Sharp
Lawrence Livermore National Laboratory , Livermore, California 94550, USA
3 shared publications - Peter R. Nyholm
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
3 shared publications R. B. Petre
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
3 shared publications- S. B. Morioka
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
3 shared publications - A. E. Peterson
Nevada National Security Site 1 , Livermore Operations, Livermore, California 94550
2 shared publications
Latest Publications
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
First results from the time resolved opacity spectrometer on the National Ignition Facility (invited)
Radiative opacity plays a central role in determining stellar structure, with iron contributing significantly to the solar opacity, particularly near the radiation–convection boundary. Current atomic models of opacity remain a major source of uncertainty, factoring into discrepancies between standard solar models and helioseismic observations. Agreement with models could be attained if key opacity values were 10%–50% larger, motivating high-precision experimental benchmarks at stellar interior conditions. The Opacity-on-National Ignition Facility campaign measures iron opacity via x-ray transmission through samples heated in a hohlraum. Previous measurements using the time-integrated opacity spectrometer (OpSpec) have been limited to temperatures <160 eV and electron densities ∼1021–1022 cm−3. Higher temperatures are achievable, but measurements were precluded by strong background emission. To address this limitation, a new time-resolved spectrometer, OpSpecTR, was developed. OpSpecTR employs an elliptically bent crystal and a grazing-incidence x-ray mirror to achieve high spectral purity, and a small crossover slit to minimize background. Time-resolved spectra in the 1–2 keV range are recorded on three ns-gated hCMOS detectors, simultaneously measuring transmitted, backlighter, and self-emission signals required for opacity extraction. Nanosecond-scale gating isolates the backlighter pulse and reduces background contributions by up to 70%. Spectral resolving power is also improved ∼2× relative to the time-integrated instrument. The first results from OpSpecTR presented herein demonstrate significantly improved fidelity in opacity measurements under high-temperature conditions, advancing experimental constraints on stellar opacity models.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
First results from the time resolved opacity spectrometer on the National Ignition Facility (invited)
Radiative opacity plays a central role in determining stellar structure, with iron contributing significantly to the solar opacity, particularly near the radiation–convection boundary. Current atomic models of opacity remain a major source of uncertainty, factoring into discrepancies between standard solar models and helioseismic observations. Agreement with models could be attained if key opacity values were 10%–50% larger, motivating high-precision experimental benchmarks at stellar interior conditions. The Opacity-on-National Ignition Facility campaign measures iron opacity via x-ray transmission through samples heated in a hohlraum. Previous measurements using the time-integrated opacity spectrometer (OpSpec) have been limited to temperatures <160 eV and electron densities ∼1021–1022 cm−3. Higher temperatures are achievable, but measurements were precluded by strong background emission. To address this limitation, a new time-resolved spectrometer, OpSpecTR, was developed. OpSpecTR employs an elliptically bent crystal and a grazing-incidence x-ray mirror to achieve high spectral purity, and a small crossover slit to minimize background. Time-resolved spectra in the 1–2 keV range are recorded on three ns-gated hCMOS detectors, simultaneously measuring transmitted, backlighter, and self-emission signals required for opacity extraction. Nanosecond-scale gating isolates the backlighter pulse and reduces background contributions by up to 70%. Spectral resolving power is also improved ∼2× relative to the time-integrated instrument. The first results from OpSpecTR presented herein demonstrate significantly improved fidelity in opacity measurements under high-temperature conditions, advancing experimental constraints on stellar opacity models.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Design and characterization of the time-resolved opacity spectrometer (OpSpecTR) for the NIF iron opacity campaign
A new time-resolved opacity spectrometer (OpSpecTR) is currently under development for the National Ignition Facility (NIF) opacity campaign. The spectrometer utilizes Icarus version 2 (IV2) hybridized complementary metal–oxide–semiconductor sensors to collect gated data at the time of the opacity transmission signal, unlocking the ability to collect higher-temperature measurements on NIF. Experimental conditions to achieve higher temperatures are feasible; however, backgrounds will dominate the data collected by the current time-integrating opacity spectrometer. The shortest available OpSpecTR integration time of ∼2 ns is predicted to reduce self-emission and other late-time backgrounds by up to 80%. Initially, three Icarus sensors will be used to collect data in the self-emission, backlighter, and absorption regions of the transmission spectrum, with plans to upgrade to five Daedalus sensors in future implementations with integration times of ∼1.3 ns. We present the details of the diagnostic design along with recent characterization results of the IV2 sensors.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Design and characterization of the time-resolved opacity spectrometer (OpSpecTR) for the NIF iron opacity campaign
A new time-resolved opacity spectrometer (OpSpecTR) is currently under development for the National Ignition Facility (NIF) opacity campaign. The spectrometer utilizes Icarus version 2 (IV2) hybridized complementary metal–oxide–semiconductor sensors to collect gated data at the time of the opacity transmission signal, unlocking the ability to collect higher-temperature measurements on NIF. Experimental conditions to achieve higher temperatures are feasible; however, backgrounds will dominate the data collected by the current time-integrating opacity spectrometer. The shortest available OpSpecTR integration time of ∼2 ns is predicted to reduce self-emission and other late-time backgrounds by up to 80%. Initially, three Icarus sensors will be used to collect data in the self-emission, backlighter, and absorption regions of the transmission spectrum, with plans to upgrade to five Daedalus sensors in future implementations with integration times of ∼1.3 ns. We present the details of the diagnostic design along with recent characterization results of the IV2 sensors.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance
The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. We also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance
The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. We also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.
- Open Access
- 1 January 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (1)
Development of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser
Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for Ephoton=0.5–30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at Ilaser≈2×1018 W/cm2 with CPCs is observed, with doses of >10 rad in air at 1 m for Ephoton>0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. These results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.
- 1 January 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (1)
Open AccessDevelopment of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser
Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for Ephoton=0.5–30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at Ilaser≈2×1018 W/cm2 with CPCs is observed, with doses of >10 rad in air at 1 m for Ephoton>0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. These results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.