Amaia Villa-Abaunza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amaia Villa-Abaunza has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jose Manuel Udias
Universidad Complutense de Madrid
7 shared publications - Paula Ibáñez
Departamento de Estructura de la Materia, Física Térmica y Electrónica, Universidad Complutense de Madrid, Avenida Complutense S/N, Facultad de Ciencias Físicas, Madrid, 28040, SPAIN
7 shared publications - Fernando Arias-Valcayo
Grupo de Física Nuclear, EMFTEL & IPARCOS, Universidad Complutense de Madrid, Pl. de las Ciencias, 1, Moncloa - Aravaca, 28040 Madrid, Madrid, 28040, SPAIN
3 shared publications - Joaquin Lopez Herraiz
Nuclear Physics Group and IPARCOS Complutense University of Madrid, Madrid, Spain, Madrid, Comunidad de Madrid, 28040, SPAIN
3 shared publications - Clara Freijo
Nuclear Physics Group, EMFTEL and IPARCOS, Faculty of Physical Sciences, University Complutense of Madrid, CEI Moncloa, 28040 Madrid, Spain
2 shared publications - Gabriela Moreno
Nuclear Physics Group, EMFTEL and IPARCOS, Faculty of Physical Sciences, University Complutense of Madrid, CEI Moncloa, 28040 Madrid, Spain
2 shared publications
Latest Publications
- Open Access
- 9 August 2024
- Published by Springer Nature in Research Square
PRIMO-PenEasy Monte Carlo simulation compared with dosimetric results for 6MV photon beams in small fields
Dosimetric validation of clinically prescribed plans for small fields requires adapted instrumentation that ensures high accuracy and spatial resolution. The objective of this study is to propose a solution by employing PRIMO-penEasy MC simulation for scenarios where obtaining direct measurements is impractical, poses challenges, or leads to inconsistencies in measurements from various detectors when assessing treatments involving small fields. This study presents the application of three distinct tools: the Semiflex ionization chamber PTW, model 31010, placed in an acrylic tank filled with water; EBT3 radiochromic films positioned between layers of a solid water phantom; and PRIMO-PenEasy Monte Carlo (MC) simulations for small photon beams. The experimental dosimetric outcomes were acquired at San Ignacio University Hospital in Bogota, Colombia, involving two small fields and one conventional field. These fields were generated using an Axesse-type linear accelerator. Radiochromic film show better agreement with MC simulation compared to the semiflex ionization chamber data, due to the fact that measurements with the 1 ionization chamber involve averaging the dose across the detection volume. Additionally, variations in off-axis ratios are observed in both crossplane and inplane directions. This difference is more evident in the case of two small fields compared to a conventional field. This observation can be attributed to the specific opening direction of the multi-blade collimation system and XY-jaws. Our study demonstrated that PRIMO-PenEasy MC simulation provides precise dose distributions and can be used as an alternative computational method to obtain the characteristics of small photon beams from an Axesse-type linear accelerator. The simulation results offer a means to reconcile disparities observed in values measured with different detectors. The values computed by PRIMO-PenEasy Monte Carlo (MC) can serve as a reliable indicator of accuracy and, consequently, be employed for dosimetric validation of prescribed clinical plans.
- 9 August 2024
- Published by Springer Nature in Research Square
Open AccessPRIMO-PenEasy Monte Carlo simulation compared with dosimetric results for 6MV photon beams in small fields
Dosimetric validation of clinically prescribed plans for small fields requires adapted instrumentation that ensures high accuracy and spatial resolution. The objective of this study is to propose a solution by employing PRIMO-penEasy MC simulation for scenarios where obtaining direct measurements is impractical, poses challenges, or leads to inconsistencies in measurements from various detectors when assessing treatments involving small fields. This study presents the application of three distinct tools: the Semiflex ionization chamber PTW, model 31010, placed in an acrylic tank filled with water; EBT3 radiochromic films positioned between layers of a solid water phantom; and PRIMO-PenEasy Monte Carlo (MC) simulations for small photon beams. The experimental dosimetric outcomes were acquired at San Ignacio University Hospital in Bogota, Colombia, involving two small fields and one conventional field. These fields were generated using an Axesse-type linear accelerator. Radiochromic film show better agreement with MC simulation compared to the semiflex ionization chamber data, due to the fact that measurements with the 1 ionization chamber involve averaging the dose across the detection volume. Additionally, variations in off-axis ratios are observed in both crossplane and inplane directions. This difference is more evident in the case of two small fields compared to a conventional field. This observation can be attributed to the specific opening direction of the multi-blade collimation system and XY-jaws. Our study demonstrated that PRIMO-PenEasy MC simulation provides precise dose distributions and can be used as an alternative computational method to obtain the characteristics of small photon beams from an Axesse-type linear accelerator. The simulation results offer a means to reconcile disparities observed in values measured with different detectors. The values computed by PRIMO-PenEasy Monte Carlo (MC) can serve as a reliable indicator of accuracy and, consequently, be employed for dosimetric validation of prescribed clinical plans.
- 5 May 2024
- Published by Elsevier in Brachytherapy
- Vol. 23 (4) , 470-477
Impact on the estimated dose of different tissue assignment strategies during partial breast irradiations with INTRABEAM
- 5 May 2024
- Published by Elsevier in Brachytherapy
- Vol. 23 (4) , 470-477
Impact on the estimated dose of different tissue assignment strategies during partial breast irradiations with INTRABEAM
- Open Access
- 30 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (3) , 035018
UMC-PET: a fast and flexible Monte Carlo PET simulator
Objective. The GPU-based Ultra-fast Monte Carlo positron emission tomography simulator (UMC-PET) incorporates the physics of the emission, transport and detection of radiation in PET scanners. It includes positron range, non-colinearity, scatter and attenuation, as well as detector response. The objective of this work is to present and validate UMC-PET as a a multi-purpose, accurate, fast and flexible PET simulator. Approach. We compared UMC-PET against PeneloPET, a well-validated MC PET simulator, both in preclinical and clinical scenarios. Different phantoms for scatter fraction (SF) assessment following NEMA protocols were simulated in a 6R-SuperArgus and a Biograph mMR scanner, comparing energy histograms, NEMA SF, and sensitivity for different energy windows. A comparison with real data reported in the literature on the Biograph scanner is also shown. Main results. NEMA SF and sensitivity estimated by UMC-PET where within few percent of PeneloPET predictions. The discrepancies can be attributed to small differences in the physics modeling. Running in a 11 GB GeForce RTX 2080 Ti GPU, UMC-PET is ∼1500 to ∼2000 times faster than PeneloPET executing in a single core Intel(R) Xeon(R) CPU W-2155 @ 3.30 GHz. Significance. UMC-PET employs a voxelized scheme for the scanner, patient adjacent objects (such as shieldings or the patient bed), and the activity distribution. This makes UMC-PET extremely flexible. Its high simulation speed allows applications such as MC scatter correction, faster SRM estimation for complex scanners, or even MC iterative image reconstruction.
- 30 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (3) , 035018
Open AccessUMC-PET: a fast and flexible Monte Carlo PET simulator
Objective. The GPU-based Ultra-fast Monte Carlo positron emission tomography simulator (UMC-PET) incorporates the physics of the emission, transport and detection of radiation in PET scanners. It includes positron range, non-colinearity, scatter and attenuation, as well as detector response. The objective of this work is to present and validate UMC-PET as a a multi-purpose, accurate, fast and flexible PET simulator. Approach. We compared UMC-PET against PeneloPET, a well-validated MC PET simulator, both in preclinical and clinical scenarios. Different phantoms for scatter fraction (SF) assessment following NEMA protocols were simulated in a 6R-SuperArgus and a Biograph mMR scanner, comparing energy histograms, NEMA SF, and sensitivity for different energy windows. A comparison with real data reported in the literature on the Biograph scanner is also shown. Main results. NEMA SF and sensitivity estimated by UMC-PET where within few percent of PeneloPET predictions. The discrepancies can be attributed to small differences in the physics modeling. Running in a 11 GB GeForce RTX 2080 Ti GPU, UMC-PET is ∼1500 to ∼2000 times faster than PeneloPET executing in a single core Intel(R) Xeon(R) CPU W-2155 @ 3.30 GHz. Significance. UMC-PET employs a voxelized scheme for the scanner, patient adjacent objects (such as shieldings or the patient bed), and the activity distribution. This makes UMC-PET extremely flexible. Its high simulation speed allows applications such as MC scatter correction, faster SRM estimation for complex scanners, or even MC iterative image reconstruction.
- Open Access
- 12 December 2023
- Published by MDPI AG in Algorithms
- Vol. 16 (12) , 565
Robustness of Single- and Dual-Energy Deep-Learning-Based Scatter Correction Models on Simulated and Real Chest X-rays
Chest X-rays (CXRs) represent the first tool globally employed to detect cardiopulmonary pathologies. These acquisitions are highly affected by scattered photons due to the large field of view required. Scatter in CXRs introduces background in the images, which reduces their contrast. We developed three deep-learning-based models to estimate and correct scatter contribution to CXRs. We used a Monte Carlo (MC) ray-tracing model to simulate CXRs from human models obtained from CT scans using different configurations (depending on the availability of dual-energy acquisitions). The simulated CXRs contained the separated contribution of direct and scattered X-rays in the detector. These simulated datasets were then used as the reference for the supervised training of several NNs. Three NN models (single and dual energy) were trained with the MultiResUNet architecture. The performance of the NN models was evaluated on CXRs obtained, with an MC code, from chest CT scans of patients affected by COVID-19. The results show that the NN models were able to estimate and correct the scatter contribution to CXRs with an error of <5%, being robust to variations in the simulation setup and improving contrast in soft tissue. The single-energy model was tested on real CXRs, providing robust estimations of the scatter-corrected CXRs.
- 12 December 2023
- Published by MDPI AG in Algorithms
- Vol. 16 (12) , 565
Open AccessRobustness of Single- and Dual-Energy Deep-Learning-Based Scatter Correction Models on Simulated and Real Chest X-rays
Chest X-rays (CXRs) represent the first tool globally employed to detect cardiopulmonary pathologies. These acquisitions are highly affected by scattered photons due to the large field of view required. Scatter in CXRs introduces background in the images, which reduces their contrast. We developed three deep-learning-based models to estimate and correct scatter contribution to CXRs. We used a Monte Carlo (MC) ray-tracing model to simulate CXRs from human models obtained from CT scans using different configurations (depending on the availability of dual-energy acquisitions). The simulated CXRs contained the separated contribution of direct and scattered X-rays in the detector. These simulated datasets were then used as the reference for the supervised training of several NNs. Three NN models (single and dual energy) were trained with the MultiResUNet architecture. The performance of the NN models was evaluated on CXRs obtained, with an MC code, from chest CT scans of patients affected by COVID-19. The results show that the NN models were able to estimate and correct the scatter contribution to CXRs with an error of <5%, being robust to variations in the simulation setup and improving contrast in soft tissue. The single-energy model was tested on real CXRs, providing robust estimations of the scatter-corrected CXRs.
- Open Access
- 16 November 2023
- Published by MDPI AG in Preprints.org
Robustness of Single and Dual-Energy Deep Learning-Based Scatter Correction Models on Simulated and Real Chest X-rays
Chest X-ray (CXR) is the first tool globally employed to detect cardiopulmonary pathologies. These acquisitions are highly affected by scattered photons due to the large field-of-view required. Scatter in CXRs introduces background in the images, which reduces their contrast. We developed three deep learning-based models to estimate and correct the scatter contribution to CXRs. We used a Monte Carlo (MC) ray-tracing model to simulate CXRs from human models obtained from CT scans using different configurations (depending on the availability of dual-energy acquisitions). The simulated CXRs contained the separated contribution of direct and scattered X-rays in the detector. These simulated datasets were then used as the reference for the supervised training of several NN. Three NN models (single and dual energy) were trained with the MultiResUNet architecture. The performance of the NN models was evaluated on CXRs obtained with the MC code from chest CTs of patients affected by COVID-19. The results showed that the NN models were able to estimate and correct the scatter contribution to CXRs with an error <5%, being robust to variations in the simulation setup and improving the contrast in soft tissue. The single-energy model was tested with real CXRs, providing robust estimations of the scatter-corrected CXRs.
- 16 November 2023
- Published by MDPI AG in Preprints.org
Open AccessRobustness of Single and Dual-Energy Deep Learning-Based Scatter Correction Models on Simulated and Real Chest X-rays
Chest X-ray (CXR) is the first tool globally employed to detect cardiopulmonary pathologies. These acquisitions are highly affected by scattered photons due to the large field-of-view required. Scatter in CXRs introduces background in the images, which reduces their contrast. We developed three deep learning-based models to estimate and correct the scatter contribution to CXRs. We used a Monte Carlo (MC) ray-tracing model to simulate CXRs from human models obtained from CT scans using different configurations (depending on the availability of dual-energy acquisitions). The simulated CXRs contained the separated contribution of direct and scattered X-rays in the detector. These simulated datasets were then used as the reference for the supervised training of several NN. Three NN models (single and dual energy) were trained with the MultiResUNet architecture. The performance of the NN models was evaluated on CXRs obtained with the MC code from chest CTs of patients affected by COVID-19. The results showed that the NN models were able to estimate and correct the scatter contribution to CXRs with an error <5%, being robust to variations in the simulation setup and improving the contrast in soft tissue. The single-energy model was tested with real CXRs, providing robust estimations of the scatter-corrected CXRs.
- Open Access
- 3 January 2023
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 206
Design of an X-ray irradiator based on a standard imaging X-ray tube with FLASH dose-rate capabilities for preclinical research
- 3 January 2023
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 206
Open AccessDesign of an X-ray irradiator based on a standard imaging X-ray tube with FLASH dose-rate capabilities for preclinical research
- 31 August 2019
- Published by Springer Nature
- p. 251-253
The Path Towards Low Dose CT: The Case of Breast CBCT
- 31 August 2019
- Published by Springer Nature
- p. 251-253
The Path Towards Low Dose CT: The Case of Breast CBCT