ZLZhongxiang Li

Zhongxiang Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhongxiang Li has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental Study on the Cumulative Deformation Effects of Power Transformer Windings Using Fiber Bragg Grating Sensors

    by Hang Guo, Xu Li, Jun Liu, She Chen, Dengfeng Zhu, Feng Wang, Litong Li, Zhongxiang Li

    Power transformers undergo cumulative winding deformation and potential failure when subjected to multiple short-circuit impacts. However, existing methods for detecting winding deformation are susceptible to interference from test setup and complex on-site environments, and they have low identification accuracy, making it difficult to capture the cumulative process of micro-deformation in windings under multiple impacts and accurately locate the deformation positions. To further investigate the cumulative deformation process of transformer windings under multiple short-circuit impacts and locate the deformation positions, this study proposes a method for high-precision measurement of winding deformation using a quasi-distributed fiber Bragg grating (FBG) sensor based on winding structure arrangement. Its grating zone can be as short as millimeter-level, achieving strain measurement accuracy of 4.5με, and can withstand up to 18 consecutive short-circuit current impacts. A short-circuit impact test model was designed, and experiments with different current ratios were conducted. Strain waveforms at various points were successfully monitored, and strain characteristics were extracted to analyze the de-formation accumulation patterns and locate the deformation positions. Finally, the transformer windings are disassembled and analyzed to verify the monitoring results. The results indicate that as the number of short circuits increases, the deformation accumulation process of the winding is not slowed down by changes in the current ratio. The radial deformation accumulation degree is positively correlated with the strain peak. Additionally, the deformation accumulation degree of windings that only undergo radial deformation is also positively correlated with the strain before the impact. The strain monitoring results are highly consistent with the actual deformation locations, verifying the effectiveness, sensitivity, and accuracy of FBG monitoring for winding deformation. This can effectively assist in diagnosing winding deformation conditions and provide a basis for assessing the status of windings in operational aging transformers.


  • Open Access

    Study on electromagnetic-force characteristics of silicon steel sheet and vibration noise of transformer under different tensile and compressive stresses

    by Zhongxiang Li, Linglong Cai, Zhiqin Ma, Xianghui Chang, Yihua Qian, Kunyu Song, Quansheng Zhao

    In this paper, the electromagnetic, vibration, and noise performance of transformers under different tensile and compressive stresses is studied. First, the magnetic properties of silicon steel sheets in transformer cores under different tensile and compressive stresses are studied. The B–H curve, B–P curve, and permeability curve of silicon steel sheets under different tensile and compressive stresses are presented. Second, the magnetostrictive characteristics of silicon steel sheets are tested and analyzed, and the butterfly curve and magnetostrictive single-valued curve of silicon steel sheets are presented. Based on the test results of magnetic and magnetostrictive properties of silicon steel sheets, the electromagnetic performance and vibration noise of a 3 kVA transformer are simulated and analyzed using COMSOL finite element software. In the simulation process, the influence of different tensile and compressive stresses on the performance of silicon steel sheets in transformer cores is considered. Finally, an experimental platform for transformer vibration and noise without compressive stress is built, and experimental research on vibration acceleration and noise of transformers under 2 and 6 MPa compressive stresses is carried out, providing a new perspective for the electromagnetic-vibration and noise analysis of transformers.


  • Open Access

    Experimental Investigation on Cumulative Effects of Transformer Winding Deformation Under Short‐Circuit Impulses

    by Jun Liu, She Chen, Feng Wang, Dengfeng Zhu, Xu Li, Yao Zhong, Zhongxiang Li

    Power transformer windings are susceptible to deformation after multiple short‐circuit impulses, threatening power grid stability. Currently, there is a lack of experimental data on various characteristic parameters of failures after multiple short‐circuit impulses. To investigate winding deformation and its gradual deterioration, a mock‐up transformer was constructed to study the cumulative effects. Short‐circuit tests were conducted under different current ratios, and the cumulative effect was quantified based on short‐circuit impedance and axial force variations. A correlation was established between different current ratios, impulse number and cumulative winding deformation. The cumulative effects of winding deformation are categorised into four levels: none, minor, significant and severe. Thresholds indicating severe deformation and degraded short‐circuit withstand ability are defined by an absolute impedance change rate exceeding 1.1% and a relative rate exceeding 0.3%. Additionally, an axial force change rate of ± 20% serves as an early warning indicator, providing greater sensitivity to detecting impulse effects on winding stability compared to impedance change rate. Monitoring impedance and axial force changes provides a reliable approach to assessing transformers affected by the cumulative effects of short‐circuit and identifying the risk of winding deformation.


  • Open Access

    A Method for Identifying External Short-Circuit Faults in Power Transformers Based on Support Vector Machines

    by Hao Du, Linglong Cai, Zhiqin Ma, Zhangquan Rao, Xiang Shu, Shuo Jiang, Zhongxiang Li, Xianqiang Li

    Being a vital component of electrical power systems, transformers significantly influence the system stability and reliability of power supplies. Damage to transformers may lead to significant economic losses. The efficient identification of transformer faults holds paramount importance for the stability and security of power grids. The existing methods for identifying transformer faults include oil chromatography analysis, temperature assessment, frequency response analysis, vibration characteristic examination, and leakage magnetic field analysis. These methods suffer from limitations such as limited sensitivity, complexity in operation, and a high demand for specialized skills. In this paper, we propose a method to identify external short-circuit faults of power transformers based on fault recording data on short-circuit currents. It involves analyzing the current signals of various windings during faults, extracting appropriate features, and utilizing a classification algorithm based on a support vector machine (SVM) to determine fault types and locations. The influence of different kernel functions on the classification accuracy of SVM is discussed. The results indicate that this method can proficiently identify the type and location of external short-circuit faults in transformers, achieving an accuracy rate of 98.3%.


  • Radial stability evaluation and cumulative test of transformer windings under short-circuit condition

    by Zhongxiang Li, Yanghong Tan, Yong Li, Xian Yang, Zhonghuan Su, Jun Liu, Shaoyang Wang, Yuankai Wang


  • Open Access

    Evaluation of ability to withstand short circuit and development of large capacity 500 kV autotransformer

    by Zhongxiang Li, Yanghong Tan, Yong Li, Xiaoqing Lin, Jun Liu, Shaoyang Wang, Hao Zhong, Yiqin Zhu

    Once the short circuit damage accident of a large capacity 500 kV transformer occurs suddenly, it will seriously affect the safe operation of the power grid. The article expounds on the calculation principle and evaluation method of the transformer's ability to withstand short circuit, then introduces the design structure of 400 MVA/500 kV short circuit autotransformer and calculates the electromagnetic force and evaluates the ability to withstand short circuit under high voltage ‐ medium voltage (HV‐MV) and medium voltage ‐ low voltage (MV‐LV) conditions. By comparing with typical 110 kV and 220 kV transformers, the short‐circuit characteristics are analysed, the control strategy is proposed, and the largest capacity short circuit prototype with 400 MVA/500 kV autotransformer is developed. Last, the sudden short circuit test is carried out in the large current test centre. The results show that the large capacity autotransformer passed the big current impulse under HV‐MV and MV‐LV short circuit conditions for the first time in the world, and all indicators are good, which confirms the accuracy of the strength check and the effectiveness of the short circuit evaluation method and also proves that the 500 kV autotransformer has strong strength to withstand short circuits.


  • Open Access

    Radial Stability Evaluation and Cumulative Test of Transformer Windings Under Short- Circuit Condition

    by Zhongxiang Li, Yanghong Tan, Yong Li, Xian Yang, Zhonghuan Su, Jun Liu, Shaoyang Wang, Yuankai Wang

    The radial instability of transformer winding under short-circuit condition is one of the vital factors leading to failures. There have been many analytic and simulative investigations in the past. However, few contributions show experiments on transformers for radial stability due to the limitation of test conditions and high costs. This paper introduces the calculation of short-circuit force and puts forward the evaluation method of radial stability. Experiments are performed on real 110kV transformers in order to validate the proposed method. To obtain the radial critical instability state and short-circuit accumulation characteristics of a transformer, dozens of short-circuit and accumulation tests have been carried out under HV-MV short-circuit conditions. The experimental results prove that the accuracy of the evaluation method of radial stability, and the current deviation is less than 5%. The tests show that the critical radial instability of the transformer can be obtained accurately by accumulating and increasing the value of short-circuit current. The sudden change of reactance during the test can reflect the characteristics of sudden deformation and instability of windings, which can be used as a judgment basis for critical instability. Moreover, the tests confirm the existence of short-circuit cumulative effect in a transformer.