PLPatrick M. Lehmann

Patrick M. Lehmann

*This is an algorithmically generated author record based on publicly available information.

Patrick M. Lehmann has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    First Clinical Experiences with the Ultra-Fast Time-of-Flight BIOGRAPH One Next-Generation Hybrid PET/MRI System

    by Otto M. Henriksen, Kirsten Korsholm, Annika Loft, Johanna M. Hall, Annika R. Langkilde, Vibeke A. Larsen, Thomas S. Kristensen, Caroline Ewertsen, Frederikke E. Høi-Hansen, Patrick M. Lehmann, et al.

    Objective : We present the first clinical experience with the BIOGRAPH One next-generation PET/MRI system scanner, evaluating its performance for body and brain imaging in patients across multiple tracers. Methods: A total of 59 patients were scanned on the BIOGRAPH One PET/MRI following standard clinical PET/CT (n = 52) or first-generation PET/MRI (Biograph mMR, n = 7). Scans comprised 30 total body (TB), whole body (WB), or regional scans with [18F]FDG, and 29 brain scans with either [18F]FDG (n = 5), [18F]FE-PE2I (n = 10), [18F]FET (n = 4), or [68Ga]Ga-DOTATOC (n = 10). The PET image quality was visually assessed using a 5-point Likert scale (1 = very good to 5 = very bad) and compared with clinical scans acquired on either a current-generation digital PET/CT or a first-generation PET/MRI system, including evaluation of diagnostic concordance. PET quantification and image noise was compared in brain and WB/TB [18F]FDG PET scans. Results: PET image quality was rated as good or very good in 93% of scans with a median [inter-quartile range] score of 1.5 [1.5;2]. In 99% of cases, image quality was judged equal to or better than the clinical reference scan (median score 3 [2.5;3]). Diagnostic concordance was observed in 99% of readings. Imaging metrics revealed the anticipated regional bias in brain imaging, while no significant bias was observed in body imaging. Image noise was comparable to that observed with digital PET/CT and demonstrated superiority over first-generation PET/MRI despite potential degradation related to isotope decay in BIOGRAPH One PET/MRI acquisitions scans performed at the end of the imaging workflow. Conclusions: Within the study limitations related to sequential imaging, the BIOGRAPH One PET/MRI scanner demonstrated improved PET sensitivity and workflow potential over its first-generation predecessor, which may allow for broader clinical and research applications.


  • Open Access

    A numerical human brain phantom for dynamic glucose‐enhanced (DGE) MRI: On the influence of head motion at 3T

    by Patrick M. Lehmann, Anina Seidemo, Mads Andersen, Xiang Xu, Xu Li, Nirbhay N. Yadav, Ronnie Wirestam, Patrick Liebig, Frederik Testud, Pia Sundgren, et al.

    Purpose: Dynamic glucose‐enhanced (DGE) MRI relates to a group of exchange‐based MRI techniques where the uptake of glucose analogues is studied dynamically. However, motion artifacts can be mistaken for true DGE effects, while motion correction may alter true signal effects. The aim was to design a numerical human brain phantom to simulate a realistic DGE MRI protocol at 3T that can be used to assess the influence of head movement on the signal before and after retrospective motion correction.Methods: MPRAGE data from a tumor patient were used to simulate dynamic Z‐spectra under the influence of motion. The DGE responses for different tissue types were simulated, creating a ground truth. Rigid head movement patterns were applied as well as physiological dilatation and pulsation of the lateral ventricles and head‐motion‐induced B0‐changes in presence of first‐order shimming. The effect of retrospective motion correction was evaluated.Results: Motion artifacts similar to those previously reported for in vivo DGE data could be reproduced. Head movement of 1 mm translation and 1.5 degrees rotation led to a pseudo‐DGE effect on the order of 1% signal change. B0 effects due to head motion altered DGE changes due to a shift in the water saturation spectrum. Pseudo DGE effects were partly reduced or enhanced by rigid motion correction depending on tissue location.Conclusion: DGE MRI studies can be corrupted by motion artifacts. Designing post‐processing methods using retrospective motion correction including B0 correction will be crucial for clinical implementation. The proposed phantom should be useful for evaluation and optimization of such techniques.