    Research and Application of High‐Sensitivity Grounding Fault Startup Method for Forest and Grassland Distribution Networks Based on Zero‐Sequence Voltage Vector

    by Hua Zhang, Xueneng Su, Yiwen Gao, Xin Ning, Jinhao Shen, Lingxu Qiao, Hongji Zheng, Cheng Long, Jian Zhang, Mu Lin

    Single‐phase ground faults in forest and grassland distribution networks pose a risk of igniting wildfires, necessitating enhanced fault detection and handling. However, the transitional resistance of faults such as tree‐line faults is generally high, and the current mainstream fault detection technologies for ground faults lack sufficient high‐resistance detection capability, which is inadequate for wildfire prevention scenarios. This paper proposes a high‐sensitivity ground fault detection method based on zero‐sequence voltage, which can enhance the high‐resistance detection capability up to 100 kΩ. By analysing the general characteristics of ground faults in distribution networks, the relationship between fault features and system network parameters is revealed. The structural characteristics of distribution networks in forest and grassland areas are summarised, and a method for actively enhancing fault zero‐sequence voltage signals is proposed. Based on zero‐sequence voltage, a high‐sensitivity ground startup is constructed and methods for achieving startup sensitivity, reliability and selectivity are explained. Finally, the performance of the proposed method is validated through simulations and field application cases.


  • Study on Corrosion Characteristics of the Contact Strips of the Valve-side Bushing of the UHV Converter Transformer

    by Huarun Cheng, Kai Liu, Mu Lin, Zhen Ding, Hao Tang, Guangning Wu

    The valve-side bushing of the UHV converter transformer is one of the key pieces of equipment in the DC transmission projects, which has been bearing the high voltage and large current of the system during long-term operation. As the most commonly used electrical contact element in the valve-side bushing of the UHV converter, the contact strips are prone to deterioration and failure in the harsh operating environment. In this paper, taking the actual fault of the contact strips at the valve-side bushing of a transformer in a UHV converter station in 2021 as an example, the corrosion characteristics of the contact strips in the valve-side bushings were investigated by scanning electron microscope (SEM), energy dispersive spectrometer (EDS), X-ray diffractometer (XRD), and the microscopic changes of corrosion products during the corrosion deterioration of the contact strips were observed, and the element distribution and main components of the corrosion layer were determined. Through the contact resistance comparison experiment of the contact strips with and without the corrosion layer, the influence of corrosion on the contact performance of the contact strip was studied.


  • Open Access

    A zero‐sample state evaluation model for valve‐side bushing of UHV converter transformer oriented to digital twin under attribute analysis

    by Zheng Li, Kai Liu, Mu Lin, Dongli Xin, Hao Tang, Guangning Wu

    The valve‐side bushing of the UHV converter transformer is the key equipment in the DC transmission project, and its running state directly affects the security and stability of the power system. This paper analyses the attributes of the physical entities, uses the digital twins to establish the state feature set and proposes a zero‐sample state evaluation algorithm for the valve‐side bushing. First, the geometric, materials and electrical characteristics are analyzed, and the detailed components of carrier current are obtained by empirical mode decomposition. Then, COMSOL is used to establish digital twins, verify the validity of twins with axial heat distribution of bushing, and establish a state feature set with the extreme temperature inside and outside bushing. Finally, the fuzzy clustering algorithm is used to classify the state feature set, and the similarity is used as the index to realize the zero‐sample state evaluation of the valve‐side bushing. Through the demonstration and analysis of examples, the evaluation model solves the problems of difficulty in extracting the internal features, fewer fault samples, and training difficulty, which is conducive to improving the operation and maintenance management level of power transmission equipment.