Jianchi Xin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jianchi Xin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Huawei Lu
5 shared publications- Zhitao Tian
School of Power and Energy, Nanchang Hangkong University 1 , Jiangxi 330063
4 shared publications - Adil Malik
Pakistan Navy Engineering College, National University of Sciences and Technology 2 , Islamabad 44000
2 shared publications Benli Peng
School of Power and Energy, Nanchang Hangkong University 1 , Jiangxi 330063
2 shared publicationsDebin Li
2 shared publications- Huawei Lu
Naval Architecture and Ocean Engineering College, Dalian Maritime University, Dalian 116026, China
2 shared publications
Latest Publications
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Effect of upper end wall boundary layer suction on high-load helium compressor performance in thorium molten salt reactors
The performance of the helium compressor is a crucial factor in determining the efficiency of thermal-to-work conversion in thorium molten salt reactors. The high-load design approach can efficiently increase the pressure ratio while minimizing the number of compressor stages. However, due to this design technique, compressor flow passages become narrower with short blades. Consequently, the impact of the end wall boundary layer on the compressor's performance becomes a point of concern. The end wall boundary layer can be effectively controlled and regulated through the suction technique. This paper investigates the effect of suction holes at various positions and angles impacting the performance characteristic of multi-stage high-load helium compressors. This research concluded that the optimum suction axial position is at 0.3 of the suction-side arc length, the optimum circumferential position is 2.0 mm, and an angle of 120° can decrease the total-pressure loss coefficient by 10.47%. Moreover, due to the suction effect, the efficiency and total pressure ratio at the design point can be improved up to 0.29% and 0.129%, respectively.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Effect of upper end wall boundary layer suction on high-load helium compressor performance in thorium molten salt reactors
The performance of the helium compressor is a crucial factor in determining the efficiency of thermal-to-work conversion in thorium molten salt reactors. The high-load design approach can efficiently increase the pressure ratio while minimizing the number of compressor stages. However, due to this design technique, compressor flow passages become narrower with short blades. Consequently, the impact of the end wall boundary layer on the compressor's performance becomes a point of concern. The end wall boundary layer can be effectively controlled and regulated through the suction technique. This paper investigates the effect of suction holes at various positions and angles impacting the performance characteristic of multi-stage high-load helium compressors. This research concluded that the optimum suction axial position is at 0.3 of the suction-side arc length, the optimum circumferential position is 2.0 mm, and an angle of 120° can decrease the total-pressure loss coefficient by 10.47%. Moreover, due to the suction effect, the efficiency and total pressure ratio at the design point can be improved up to 0.29% and 0.129%, respectively.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Performance differences and design method improvement of Laval nozzles under superatmospheric and subatmospheric conditions
To enhance the performance of subatmospheric supersonic wind tunnels, this study explores the design of Laval nozzle profiles using the method of characteristics. For Mach numbers ranging from 1.2 to 1.8, various nozzle designs are validated using numerical simulations, and the performance differences between superatmospheric and subatmospheric conditions are analyzed. An improved formula for boundary layer correction under subatmospheric conditions is developed using the least-squares method, and its reliability is numerically verified. All nozzle designs considered in this study perform outstandingly in superatmospheric conditions, with outlet Mach number errors of less than 0.2%. Under subatmospheric conditions, the outlet Mach number errors increase by a factor of ten, and the maximum total pressure loss coefficient approaches 5.57%, representing an increase in almost 30% over the superatmospheric case. The reduced Reynolds number of subatmospheric conditions causes areas of high total pressure loss to accumulate near the wall boundary layer, which induces an increase in the boundary layer displacement of 0.2–0.4 mm and reduces the effective expansion ratio by 0.24%–0.67%. The improved boundary layer correction formula has broad applicability for Mach 1.1–2.0 nozzles under subatmospheric conditions. In such scenarios, the improved nozzles reduce the total pressure loss by 22.18%–32.37% compared with unimproved nozzles.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Performance differences and design method improvement of Laval nozzles under superatmospheric and subatmospheric conditions
To enhance the performance of subatmospheric supersonic wind tunnels, this study explores the design of Laval nozzle profiles using the method of characteristics. For Mach numbers ranging from 1.2 to 1.8, various nozzle designs are validated using numerical simulations, and the performance differences between superatmospheric and subatmospheric conditions are analyzed. An improved formula for boundary layer correction under subatmospheric conditions is developed using the least-squares method, and its reliability is numerically verified. All nozzle designs considered in this study perform outstandingly in superatmospheric conditions, with outlet Mach number errors of less than 0.2%. Under subatmospheric conditions, the outlet Mach number errors increase by a factor of ten, and the maximum total pressure loss coefficient approaches 5.57%, representing an increase in almost 30% over the superatmospheric case. The reduced Reynolds number of subatmospheric conditions causes areas of high total pressure loss to accumulate near the wall boundary layer, which induces an increase in the boundary layer displacement of 0.2–0.4 mm and reduces the effective expansion ratio by 0.24%–0.67%. The improved boundary layer correction formula has broad applicability for Mach 1.1–2.0 nozzles under subatmospheric conditions. In such scenarios, the improved nozzles reduce the total pressure loss by 22.18%–32.37% compared with unimproved nozzles.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Influence of tip clearance on the flow field of variable inlet guide vane cascade in air storage centrifugal compressor
This study investigated the impact of tip clearance on the aerodynamic performance of variable inlet guide vane (VIGV) cascade within a centrifugal compressor for compressed air energy storage. The exploration was carried out by combining numerical simulation and wind tunnel test validation. The study revealed that at 0.19Ma, tip clearance variations significantly affected the total pressure loss coefficient (Cpt), leakage flow, and deviation angle. Under small incidence angles (5°–20°), Cpt initially increased then decreased with larger clearances, peaking at 2.5% tip clearance (10% higher than original) and dropping by 30% at 10% tip clearance. Under large incidence angles (25°–30°), Cpt showed continuous reduction, achieving 30% decrease at 10% tip clearance. When tip clearance exceeded 7.5%, its impact on leakage flow diminished noticeably, while the effect on deviation angle remained limited (maximum 3° increase). This work filled a research gap regarding VIGV tip clearance effects and laid groundwork for future 3D guide vane clearance studies.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Influence of tip clearance on the flow field of variable inlet guide vane cascade in air storage centrifugal compressor
This study investigated the impact of tip clearance on the aerodynamic performance of variable inlet guide vane (VIGV) cascade within a centrifugal compressor for compressed air energy storage. The exploration was carried out by combining numerical simulation and wind tunnel test validation. The study revealed that at 0.19Ma, tip clearance variations significantly affected the total pressure loss coefficient (Cpt), leakage flow, and deviation angle. Under small incidence angles (5°–20°), Cpt initially increased then decreased with larger clearances, peaking at 2.5% tip clearance (10% higher than original) and dropping by 30% at 10% tip clearance. Under large incidence angles (25°–30°), Cpt showed continuous reduction, achieving 30% decrease at 10% tip clearance. When tip clearance exceeded 7.5%, its impact on leakage flow diminished noticeably, while the effect on deviation angle remained limited (maximum 3° increase). This work filled a research gap regarding VIGV tip clearance effects and laid groundwork for future 3D guide vane clearance studies.
- 1 July 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (7)
Frequency characterization of a sweeping jet actuator with internal geometry modification
An unsteady simulation method was conducted to investigate the internal flow mechanism of a sweeping jet actuator, with a focus on the influence of varying the ratio of the first and second chambers on the oscillation frequency. The time histories of the oscillations under seven distinct working conditions were simulated to reveal the law of frequency change. A detailed comparison involving the variation of the deflection angle, pressure, and vorticity fields under three specific working conditions was conducted from both qualitative and quantitative perspectives to explore the underlying oscillation mechanism. The results indicated that the asymmetric expansion and contraction of the vortex activated the feedback flow to generate oscillation, and the frequency of the oscillation was related to the speed of vortex expansion in the first and second chambers. The length of the second chamber determined the oscillation frequency, which could change, ranging from 1.9% to 26.9% compared to the prototype with the variation of this length scale. The internal flow dynamics had a direct impact on the characteristics of the jet within the external flow field. Furthermore, equipping the actuator on the end wall of a compressor cascade, using this actuator with only 0.11% of the cascade mass flow, the total pressure loss, factoring in the additional energy input, was reduced by 3.7%.
- 1 July 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (7)
Frequency characterization of a sweeping jet actuator with internal geometry modification
An unsteady simulation method was conducted to investigate the internal flow mechanism of a sweeping jet actuator, with a focus on the influence of varying the ratio of the first and second chambers on the oscillation frequency. The time histories of the oscillations under seven distinct working conditions were simulated to reveal the law of frequency change. A detailed comparison involving the variation of the deflection angle, pressure, and vorticity fields under three specific working conditions was conducted from both qualitative and quantitative perspectives to explore the underlying oscillation mechanism. The results indicated that the asymmetric expansion and contraction of the vortex activated the feedback flow to generate oscillation, and the frequency of the oscillation was related to the speed of vortex expansion in the first and second chambers. The length of the second chamber determined the oscillation frequency, which could change, ranging from 1.9% to 26.9% compared to the prototype with the variation of this length scale. The internal flow dynamics had a direct impact on the characteristics of the jet within the external flow field. Furthermore, equipping the actuator on the end wall of a compressor cascade, using this actuator with only 0.11% of the cascade mass flow, the total pressure loss, factoring in the additional energy input, was reduced by 3.7%.
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
Influence of axial clearance between stator and rotor blades on performance of high-loaded helium compressor cascades in high-temperature gas-cooled reactor
The high-loaded helium multi-stage compressor arrangement, driven by a hub motor, effectively addresses matching regulation challenges between the compressor and its driving turbine. This design requires the motor to be installed on the rotor hub, making axial clearance a critical factor for the integrating of rotor and stator blades. Numerical simulations and experimental validation were used to examine the effects of varying rotor-stator axial clearances, relative phase, and angle of attack on cascade efficiency. Results indicate that increasing axial clearance reduces flow capacity and increases cascade losses. At Φ = 0/4 and 4/4 with a 0° angle of attack, total pressure losses rise by 6.4% and 7.5% for Case-2 and Case-3 configurations, respectively, compared to Case-1. Despite the moderate increase in total pressure loss, the design is deemed acceptable, given operational efficiency requirements and structural challenges under high-load conditions.
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
Influence of axial clearance between stator and rotor blades on performance of high-loaded helium compressor cascades in high-temperature gas-cooled reactor
The high-loaded helium multi-stage compressor arrangement, driven by a hub motor, effectively addresses matching regulation challenges between the compressor and its driving turbine. This design requires the motor to be installed on the rotor hub, making axial clearance a critical factor for the integrating of rotor and stator blades. Numerical simulations and experimental validation were used to examine the effects of varying rotor-stator axial clearances, relative phase, and angle of attack on cascade efficiency. Results indicate that increasing axial clearance reduces flow capacity and increases cascade losses. At Φ = 0/4 and 4/4 with a 0° angle of attack, total pressure losses rise by 6.4% and 7.5% for Case-2 and Case-3 configurations, respectively, compared to Case-1. Despite the moderate increase in total pressure loss, the design is deemed acceptable, given operational efficiency requirements and structural challenges under high-load conditions.
- 1 February 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (2)
Experimental investigation of intermediate compressor duct
The intermediate duct connects high-pressure and low-pressure compressors. It comprises flow channels and struts that fix the relative positions of the hub and shroud. The mechanism of airflow movement around the struts in the downstream intermediate ducts is experimentally investigated based on four cases, including two types of struts and two shapes of meridional flow channels. The measurement parameters of the intermediate duct under the same conditions are measured in the wind tunnel, including the total pressure loss coefficient at the outlet and axial wall pressure distribution. In addition, the flow characteristics near the wall are obtained through the oil flow test, and the frequency of the shedding vortex is captured by the dynamic pressure probes. The results demonstrate that the strut and channel with the modified profile can reduce the total pressure loss and eliminate wake oscillation by changing the flow characteristic. The total pressure losses of the modified profile at 0.2, 0.25, 0.3, 0.35, 0.4, and 0.45 Ma conditions are reduced by 60%, 63%, 83%, 89%, 85%, and 87%, respectively.
- 1 February 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (2)
Experimental investigation of intermediate compressor duct
The intermediate duct connects high-pressure and low-pressure compressors. It comprises flow channels and struts that fix the relative positions of the hub and shroud. The mechanism of airflow movement around the struts in the downstream intermediate ducts is experimentally investigated based on four cases, including two types of struts and two shapes of meridional flow channels. The measurement parameters of the intermediate duct under the same conditions are measured in the wind tunnel, including the total pressure loss coefficient at the outlet and axial wall pressure distribution. In addition, the flow characteristics near the wall are obtained through the oil flow test, and the frequency of the shedding vortex is captured by the dynamic pressure probes. The results demonstrate that the strut and channel with the modified profile can reduce the total pressure loss and eliminate wake oscillation by changing the flow characteristic. The total pressure losses of the modified profile at 0.2, 0.25, 0.3, 0.35, 0.4, and 0.45 Ma conditions are reduced by 60%, 63%, 83%, 89%, 85%, and 87%, respectively.