ZTZhitao Tian

Zhitao Tian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhitao Tian has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of upper end wall boundary layer suction on high-load helium compressor performance in thorium molten salt reactors

    by Jianchi Xin, Xinle Wang, Adil Malik, Zhitao Tian, Huawei Lu

    The performance of the helium compressor is a crucial factor in determining the efficiency of thermal-to-work conversion in thorium molten salt reactors. The high-load design approach can efficiently increase the pressure ratio while minimizing the number of compressor stages. However, due to this design technique, compressor flow passages become narrower with short blades. Consequently, the impact of the end wall boundary layer on the compressor's performance becomes a point of concern. The end wall boundary layer can be effectively controlled and regulated through the suction technique. This paper investigates the effect of suction holes at various positions and angles impacting the performance characteristic of multi-stage high-load helium compressors. This research concluded that the optimum suction axial position is at 0.3 of the suction-side arc length, the optimum circumferential position is 2.0 mm, and an angle of 120° can decrease the total-pressure loss coefficient by 10.47%. Moreover, due to the suction effect, the efficiency and total pressure ratio at the design point can be improved up to 0.29% and 0.129%, respectively.


  • Performance differences and design method improvement of Laval nozzles under superatmospheric and subatmospheric conditions

    by Huawei Lu, Yanzhao Ma, Benli Peng, Jianchi Xin, Zhitao Tian, Shuang Guo, Debin Li

    To enhance the performance of subatmospheric supersonic wind tunnels, this study explores the design of Laval nozzle profiles using the method of characteristics. For Mach numbers ranging from 1.2 to 1.8, various nozzle designs are validated using numerical simulations, and the performance differences between superatmospheric and subatmospheric conditions are analyzed. An improved formula for boundary layer correction under subatmospheric conditions is developed using the least-squares method, and its reliability is numerically verified. All nozzle designs considered in this study perform outstandingly in superatmospheric conditions, with outlet Mach number errors of less than 0.2%. Under subatmospheric conditions, the outlet Mach number errors increase by a factor of ten, and the maximum total pressure loss coefficient approaches 5.57%, representing an increase in almost 30% over the superatmospheric case. The reduced Reynolds number of subatmospheric conditions causes areas of high total pressure loss to accumulate near the wall boundary layer, which induces an increase in the boundary layer displacement of 0.2–0.4 mm and reduces the effective expansion ratio by 0.24%–0.67%. The improved boundary layer correction formula has broad applicability for Mach 1.1–2.0 nozzles under subatmospheric conditions. In such scenarios, the improved nozzles reduce the total pressure loss by 22.18%–32.37% compared with unimproved nozzles.


  • Influence of tip clearance on the flow field of variable inlet guide vane cascade in air storage centrifugal compressor

    by Yilin Wang, Jianchi Xin, Fuyi Liu, Zhitao Tian, Benli Peng, Huawei Lu, Xin Lan

    This study investigated the impact of tip clearance on the aerodynamic performance of variable inlet guide vane (VIGV) cascade within a centrifugal compressor for compressed air energy storage. The exploration was carried out by combining numerical simulation and wind tunnel test validation. The study revealed that at 0.19Ma, tip clearance variations significantly affected the total pressure loss coefficient (Cpt), leakage flow, and deviation angle. Under small incidence angles (5°–20°), Cpt initially increased then decreased with larger clearances, peaking at 2.5% tip clearance (10% higher than original) and dropping by 30% at 10% tip clearance. Under large incidence angles (25°–30°), Cpt showed continuous reduction, achieving 30% decrease at 10% tip clearance. When tip clearance exceeded 7.5%, its impact on leakage flow diminished noticeably, while the effect on deviation angle remained limited (maximum 3° increase). This work filled a research gap regarding VIGV tip clearance effects and laid groundwork for future 3D guide vane clearance studies.

  • Influence of axial clearance between stator and rotor blades on performance of high-loaded helium compressor cascades in high-temperature gas-cooled reactor

    by Yuyang Chen, Huawei Lu, Adil Malik, Zhitao Tian, Jianchi Xin, Bo Wang

    The high-loaded helium multi-stage compressor arrangement, driven by a hub motor, effectively addresses matching regulation challenges between the compressor and its driving turbine. This design requires the motor to be installed on the rotor hub, making axial clearance a critical factor for the integrating of rotor and stator blades. Numerical simulations and experimental validation were used to examine the effects of varying rotor-stator axial clearances, relative phase, and angle of attack on cascade efficiency. Results indicate that increasing axial clearance reduces flow capacity and increases cascade losses. At Φ = 0/4 and 4/4 with a 0° angle of attack, total pressure losses rise by 6.4% and 7.5% for Case-2 and Case-3 configurations, respectively, compared to Case-1. Despite the moderate increase in total pressure loss, the design is deemed acceptable, given operational efficiency requirements and structural challenges under high-load conditions.


  • Effects of relative phase position of blades on the cascade performance of highly loaded helium compressor

    by Huawei Lu, Ke Sun, Adil Malik, Zhitao Tian

    The operational environment of highly loaded helium compressor necessitates characteristics with narrow flow passages and short blade heights. These characteristics result in more prominent blade tip clearance leakage issues and stronger wake effects compared to air compressors. This study aims to clarify the separation flow structure and the spatiotemporal evolution mechanism of the highly loaded helium compressor cascade and to provide technical support for the aerodynamic stability optimization of such compressors. The present study investigated the effect of the relative positions of the upstream blade wake and downstream blade on cascade loss and separation characteristics of the highly loaded helium compressor with numerical and experimental analysis. The results demonstrate that the proportion of secondary flow losses, including tip leakage vortex of the downstream blade, is the lowest when the circumferential distance between the upstream inlet guide vane wake and the downstream rotor leading edge is 0.5 pitch, with an overall loss weight of 10.8% at the outlet section. Moreover, the proportion of secondary flow losses, including tip leakage vortex of the downstream rotor, is the highest when the circumferential distance between the upstream guide vane wake and downstream rotor leading edge (suction surface side) is 0.25 pitch. The overall loss weight at the outlet section for this position is 21.7%, which is twice that when the circumferential distance is 0.5 pitch. In addition, it can be demonstrated that tip leakage vortex plays a dominant role in vortex losses across all relative positions of the blades.


  • Aerodynamic investigation of an S-shaped intake employing sweeping jet actuators based on proper orthogonal decomposition

    by Chengze Wang, Huawei Lu, Jun Liu, Zhitao Tian, Shuang Guo, Wenxuan Pang

    The central curvature change of the S-shaped intake exacerbates the three-dimensional flow separation, resulting in total pressure and swirl distortions at the outlet. In this paper, an efficient active flow control technique, the sweeping jet actuator, was applied to control flow separation. The instantaneous characteristics of the flow field inside and outside the actuator were revealed by using validated numerical simulation methods. In addition, the effect of the sweeping jet on the aerodynamic performance of the S-shaped intake was investigated. Proper orthogonal decomposition (POD), an analysis method used to extract the main feature components of data, was applied to decompose the flow field structure at the S-shaped intake outlet in this study. The results highlight the external flow field characteristics of the actuator, with a jet sweeping range of up to ±40° and a sweeping frequency of 1 500 Hz, corresponding to a Strouhal number of 0.018. When the jet momentum coefficient is only 0.116%, the total pressure loss coefficient and pressure distortion index are reduced by 5.6% and 24.76%, respectively. This study demonstrates the critical role of momentum injection and discretization in inhibiting flow separation in the channel. The POD-based analysis indicates that a sweeping jet with high momentum can significantly enhance the energy in the flow passage and reduce the vorticity intensity of the first three modes. The stable mode structures exist near the outlet, exhibiting excitation frequency and frequency-doubling properties. The findings of this research provide essential input conditions for subsequent distortion studies.