WWW. L. Waldron

W. L. Waldron

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


W. L. Waldron has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 10.1063/5.0107082.1

    by J. Soria, D. N. McKinsey, S. Kravitz, E. E. Deck, E. P. Bernard, L. Tvrznikova, W. L. Waldron, Q. Riffard, K. O’sullivan

    Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding 1 m, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a 5-l, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. In this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both the anode current and photon rate was observed in the last 30 s, leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler–Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.

  • Open Access

    Study of dielectric breakdown in liquid xenon with XeBrA: The xenon breakdown apparatus

    by J. Watson, I. Olcina, J. Soria, D. N. McKinsey, S. Kravitz, E. E. Deck, E. P. Bernard, L. Tvrznikova, W. L. Waldron, Q. Riffard, et al.

    Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding 1 m, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a 5-l, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. In this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both the anode current and photon rate was observed in the last 30 s, leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler–Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.


  • Technological Improvements in the DARHT II Accelerator Cells

    by B.A. Prichard Jr., J. Barraza, M. Kang, K. Nielsen, F. Bieniosek, K. Chow, W. Fawley, E. Henestroza, L. Reginato, W. Waldron, et al.

    The DARHT facility will employ two perpendicular electron Linear Induction Accelerators to produce intense, bremsstrahlung x-ray pulses for flash radiography. The second axis, DARHT II [1], features an 18 MeV, 2-kA, 2-microsecond pulse accelerator. DARHT II accelerator cells have undergone a series of testing and modeling efforts to fully understand their unacceptable initial failure rate. These R&D efforts are part of the DARHT 2 nd Axis Refurbishment and Commissioning project, and they have led to a better understanding of Linear Induction Accelerator technology and physics for the unique DARHT II design. Specific improvements have been identified and tested. Improvements in the cell oil region, the cell vacuum region, and the Pulse Forming Networks (PFNs) have been implemented in the prototype units that have doubled the cell’s performance. The prototype acceptance tests have been completed, and the lifetime reliability requirements were exceeded. The shortcomings of the previous design are summarized. The improvements to the original design, their resultant improvement in performance, and various test results are included.


  • Open Access

    Upgrades to the Darht Second Axis Induction Cells

    by K. Nielsen, J. Barraza, M. Kang, F. Bieniosek, K. Chow, W. Fawley, E. Henestroza, L. Reginato, W. Waldron, B. Prichard, et al.

    The Dual-Axis Radiographic Hydrodynamics Test (DARHT) facility will employ two perpendicular electron Linear Induction Accelerators to produce intense, bremsstrahlung x-ray pulses for flash radiography. The second axis, DARHT II [1], features a 3-MeV, 2-kA injector and a 15-MeV, 1.6-microsecond accelerator consisting of 74 induction cells and drivers. Major induction cell components include high flux swing magnetic material (Metglas 2605 SC) and a Mycalextrade insulator. The cell drivers are pulse forming networks (PFNs). The DARHT II accelerator cells have undergone a series of test and modeling efforts to fully understand their operational parameters. These R&D efforts have identified problems in the original cell design and means to upgrade the design, performance and reliability of the linear induction cells. Physical changes in the cell oil region, the cell vacuum region, and the cell drivers, together with different operational and maintenance procedures, have been implemented in the prototype units resulting in greatly enhanced cell performance and reliability. A series of prototype acceptance tests have demonstrated that the required cell reliability and lifetime is exceeded at the increased performance levels. Shortcomings of the original design are summarized and improvements to the design, their resultant enhancement in performance, and various test results are discussed.