Guido C. Hilgers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Guido C. Hilgers has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Agnes Angerud
RaySearch Laboratories AB, Eugeniavägen 18, Stockholm, Stockholm, 11368, SWEDEN
2 shared publicationsAndré Minken
Radiation Oncology Department, Radiotherapiegroep, P.O. Box 60160, Arnhem, 6800 JD, NETHERLANDS
2 shared publicationsBrent van der Heyden
Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Leuven, Belgium
2 shared publicationsDanny Schuring
Radiotherapiegroep, Arnhem/Deventer
2 shared publications- Esther Decabooter
Department of Radiation Oncology (Maastro clinic), GROW School for Oncology, Maastricht University Medical Centre+, Maastricht, The Netherlands
2 shared publications - Evelien Bogaert
Department of Radiation-Oncology, Ghent University Hospital, Ghent, Belgium
2 shared publications
Latest Publications
- Open Access
- 19 February 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 37
X-ray beam quality checks of a magnetic resonance-guided linear accelerator with its on-board megavoltage imager
- 19 February 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 37
Open AccessX-ray beam quality checks of a magnetic resonance-guided linear accelerator with its on-board megavoltage imager
- 23 April 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (9)
Beam modeling and validation for a 1.5 T MR-linac in an alternative treatment planning system
Objective. MR-guided adaptive radiotherapy (MRgART) is ideally suited to adjust the treatment plan for anatomical changes. The online nature of MRgART involves multiple process steps during each treatment fraction, which may greatly benefit from automation. The RAYSTATION treatment planning system incorporates automation features by design, but requires dose calculations in the presence of an external magnetic field and the modeling of the MRgART system. This study developed and commissioned a comprehensive model for the 1.5T MR-linac in RAYSTATION. Approach. MR-linac dose profiles and output factors were used to model the Unity MR-linac in RAYSTATION. The MR cryostat was implemented in the Monte Carlo simulation as a multi-layer barrel, adjusted using simulations and in-air output measurements. The cryostat transmission variation with gantry angle was added as a fluence correction. Dose distributions of on-axis square, off-axis square, and 90 IMRT fields of ten prostate MR-linac treatment plans were evaluated with the PTW Octavius 1500MR detector array. The radiofrequency coils and couch were characterized with megavoltage imager transmission measurements. CT scans of the coils were used to model its geometry in RAYSTATION and mass densities were assigned to match the measured attenuation. Results. Differences between measured and calculated depth dose showed a γ < 0.5 beyond dmax. For both the inline and crossline profiles, the γ evaluation exhibited a γ < 1.0 for nearly all evaluated points. The maximum difference between the measured and calculated cryostat scatter was 0.6%. The average γ pass rate for the on-axis, off-axis, and IMRT fields was >98.3% (range: 91.2 – 100%). The average coil transmissions were 0.6 (anterior) and 2.2% (posterior). Significance. We successfully modelled and commissioned the 1.5T MR-linac in RAYSTATION well within tolerance limits as specified by the AAPM TG-157.
- 23 April 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (9)
Beam modeling and validation for a 1.5 T MR-linac in an alternative treatment planning system
Objective. MR-guided adaptive radiotherapy (MRgART) is ideally suited to adjust the treatment plan for anatomical changes. The online nature of MRgART involves multiple process steps during each treatment fraction, which may greatly benefit from automation. The RAYSTATION treatment planning system incorporates automation features by design, but requires dose calculations in the presence of an external magnetic field and the modeling of the MRgART system. This study developed and commissioned a comprehensive model for the 1.5T MR-linac in RAYSTATION. Approach. MR-linac dose profiles and output factors were used to model the Unity MR-linac in RAYSTATION. The MR cryostat was implemented in the Monte Carlo simulation as a multi-layer barrel, adjusted using simulations and in-air output measurements. The cryostat transmission variation with gantry angle was added as a fluence correction. Dose distributions of on-axis square, off-axis square, and 90 IMRT fields of ten prostate MR-linac treatment plans were evaluated with the PTW Octavius 1500MR detector array. The radiofrequency coils and couch were characterized with megavoltage imager transmission measurements. CT scans of the coils were used to model its geometry in RAYSTATION and mass densities were assigned to match the measured attenuation. Results. Differences between measured and calculated depth dose showed a γ < 0.5 beyond dmax. For both the inline and crossline profiles, the γ evaluation exhibited a γ < 1.0 for nearly all evaluated points. The maximum difference between the measured and calculated cryostat scatter was 0.6%. The average γ pass rate for the on-axis, off-axis, and IMRT fields was >98.3% (range: 91.2 – 100%). The average coil transmissions were 0.6 (anterior) and 2.2% (posterior). Significance. We successfully modelled and commissioned the 1.5T MR-linac in RAYSTATION well within tolerance limits as specified by the AAPM TG-157.
- 14 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075004
Multileaf collimator characterization and modeling for a 1.5 T MR-linac using static synchronous and asynchronous sweeping gaps
Objective. The Elekta unity MR-linac delivers step-and-shoot intensity modulated radiotherapy plans using a multileaf collimator (MLC) based on the Agility MLC used on conventional Elekta linacs. Currently, details of the physical Unity MLC and the computational model within its treatment planning system (TPS) Monaco are lacking in published literature. Recently, a novel approach to characterize the physical properties of MLCs was introduced using dynamic synchronous and asynchronous sweeping gap (aSG) tests. Our objective was to develop a step-and-shoot version of the dynamic aSG test to characterize the Unity MLC and the computational MLC models in the Monaco and RayStation TPSs. Approach. Dynamic aSG were discretized into a step-and-shoot aSG by investigating the number of segments/sweep and the minimal number of monitor units (MU) per segment. The step-and-shoot aSG tests were compared to the dynamic aSG tests on a conventional linac at a source-to-detector distance of 143.5 cm, mimicking the Unity configuration. the step-and-shoot aSG tests were used to characterize the Unity MLC through measurements and dose calculations in both TPSs. Main results. The step-and-shoot aSGs tests with 100 segments and 5 MU/segment gave results very similar to the dynamic aSG experiments. The effective tongue-and-groove width of the Unity gradually increased up to 1.4 cm from the leaf tip end. The MLC models in RayStation and Monaco agreed with experimental data within 2.0% and 10%, respectively. The largest discrepancies in Monaco were found for aSG tests with >10 mm leaf interdigitation, which are non-typical for clinical plans. Significance. The step-and-shoot aSG tests accurately characterize the MLC in step-and-shoot delivery mode. The MLC model in RayStation 2023B accurately describes the tongue-and-groove and leaf tip effects whereas Monaco overestimates the tongue-and-groove shadowing further away from the leaf tip end.
- 14 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075004
Multileaf collimator characterization and modeling for a 1.5 T MR-linac using static synchronous and asynchronous sweeping gaps
Objective. The Elekta unity MR-linac delivers step-and-shoot intensity modulated radiotherapy plans using a multileaf collimator (MLC) based on the Agility MLC used on conventional Elekta linacs. Currently, details of the physical Unity MLC and the computational model within its treatment planning system (TPS) Monaco are lacking in published literature. Recently, a novel approach to characterize the physical properties of MLCs was introduced using dynamic synchronous and asynchronous sweeping gap (aSG) tests. Our objective was to develop a step-and-shoot version of the dynamic aSG test to characterize the Unity MLC and the computational MLC models in the Monaco and RayStation TPSs. Approach. Dynamic aSG were discretized into a step-and-shoot aSG by investigating the number of segments/sweep and the minimal number of monitor units (MU) per segment. The step-and-shoot aSG tests were compared to the dynamic aSG tests on a conventional linac at a source-to-detector distance of 143.5 cm, mimicking the Unity configuration. the step-and-shoot aSG tests were used to characterize the Unity MLC through measurements and dose calculations in both TPSs. Main results. The step-and-shoot aSGs tests with 100 segments and 5 MU/segment gave results very similar to the dynamic aSG experiments. The effective tongue-and-groove width of the Unity gradually increased up to 1.4 cm from the leaf tip end. The MLC models in RayStation and Monaco agreed with experimental data within 2.0% and 10%, respectively. The largest discrepancies in Monaco were found for aSG tests with >10 mm leaf interdigitation, which are non-typical for clinical plans. Significance. The step-and-shoot aSG tests accurately characterize the MLC in step-and-shoot delivery mode. The MLC model in RayStation 2023B accurately describes the tongue-and-groove and leaf tip effects whereas Monaco overestimates the tongue-and-groove shadowing further away from the leaf tip end.
- Open Access
- 10 December 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 29, 100523
Survey on fan-beam computed tomography for radiotherapy: Current implementation and future perspectives of motion management and surface guidance devices
- 10 December 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 29, 100523
Open AccessSurvey on fan-beam computed tomography for radiotherapy: Current implementation and future perspectives of motion management and surface guidance devices
- Open Access
- 6 December 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 29, 100522
Survey on fan-beam computed tomography for radiotherapy: Imaging for dose calculation and delineation
- 6 December 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 29, 100522
Open AccessSurvey on fan-beam computed tomography for radiotherapy: Imaging for dose calculation and delineation
- Open Access
- 11 January 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 25, 100411
Beam output checks of a commercial high-field magnetic resonance-guided radiotherapy machine with its on-board megavoltage imager
- 11 January 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 25, 100411
Open AccessBeam output checks of a commercial high-field magnetic resonance-guided radiotherapy machine with its on-board megavoltage imager
- Open Access
- 8 May 2015
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (3) , 389-398
Helical 4D CT pitch management for the Brilliance CT Big Bore in clinical practice
In external beam radiotherapy treatment planning for patients with thoracic malignancies, respiratory‐correlated CT (4D CT) is used to obtain high quality studies in the presence of respiratory motion. When helical 4D CT scans are acquired with a Brilliance CT Big Bore, the pitch must meet two conditions. It must be low enough to avoid motion artifacts, and high enough to cover the entire scan length within 120 s to prevent overheating of the X‐ray tube. We developed a nomogram that can be used to obtain a suitable pitch satisfying both requirements. We also assessed the effects on the image quality of a pitch that exceeds the maximum pitch, and of a field of view (FOV) reduction. It was shown that, for AV G and MIP reconstructions, the manufacturer's maximum pitch equation yields an underestimation due to its FOV term.PACS number: 87.57.Q‐, 87.57.cp
- 8 May 2015
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (3) , 389-398
Open AccessHelical 4D CT pitch management for the Brilliance CT Big Bore in clinical practice
In external beam radiotherapy treatment planning for patients with thoracic malignancies, respiratory‐correlated CT (4D CT) is used to obtain high quality studies in the presence of respiratory motion. When helical 4D CT scans are acquired with a Brilliance CT Big Bore, the pitch must meet two conditions. It must be low enough to avoid motion artifacts, and high enough to cover the entire scan length within 120 s to prevent overheating of the X‐ray tube. We developed a nomogram that can be used to obtain a suitable pitch satisfying both requirements. We also assessed the effects on the image quality of a pitch that exceeds the maximum pitch, and of a field of view (FOV) reduction. It was shown that, for AV G and MIP reconstructions, the manufacturer's maximum pitch equation yields an underestimation due to its FOV term.PACS number: 87.57.Q‐, 87.57.cp