JMJunqi Ma

Junqi Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junqi Ma has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    EcoTrack: Enabling Energy-Efficient Millimeter-Accurate Tracking on Commodity UWB Devices

    by Xinran Li, Junqi Ma, Fusang Zhang, Beihong Jin, Hua Zhong, Jie Xiong

    The recent integration of ultra-wideband (UWB) radios into mobile devices has opened the door to a new wave of Internet of Things (IoT) applications. While prior work has primarily focused on improving tracking accuracy, energy constraints in battery-powered mobile devices remain a persistent challenge. We present EcoTrack, a novel uplink phase-based UWB tracking system that significantly reduces energy consumption while still achieving millimeter-level accuracy. EcoTrack optimizes energy consumption by fundamentally redesigning conventional UWB tracking methods through two key strategies: (i) reducing the number of message transmissions and (ii) reducing location update rates. Specifically, departing from conventional methods that rely on multiple message exchanges, we propose an uplink scheme that requires the mobile device to broadcast only a single message for each location update. For accurate phase estimation under unsynchronized multi-anchor scenarios, we propose a two-stage differential operation to cancel the time-varying phase errors in raw phase estimates. While lowering the update rate effectively reduces energy consumption, it also introduces phase ambiguity for target tracking. To tackle this challenge, we fuse wrapped UWB phase with low-power IMU readings widely available on mobile devices to achieve robust ambiguity resolution. Extensive experiments demonstrate that EcoTrack reduces energy consumption by up to 84% compared to existing methods while maintaining a low median 3D tracking error of 0.78 cm across diverse indoor environments.

  • Open Access

    From Prototype to Nationwide Deployment: A 5-year Retrospect of a WiFi-based Outdoor Localization System

    by Fusang Zhang, Jiazhi Ni, Chang Su, Junqi Ma, Beihong Jin, Daqing Zhang, Qiang Huang, Xin Li, Chang Liu, Hongbin Luo, et al.

    While GPS-based outdoor localization has become a norm, it still faces severe issues in challenging environments such as urban canyons. In this work, we share our 5-year experience on utilizing Wi-Fi to help GPS-based outdoor localization. We analyze the coverage of outdoor Wi-Fi in the urban area on a large scale to demonstrate the feasibility of employing Wi-Fi signals for outdoor localization. For the first time, we design a Wi-Fi-GPS fusion approach to build nationwide Wi-Fi outdoor fingerprints for localization. We propose solutions to address not just technical challenges but also real-life practical challenges. Our system has been deployed nationwide in more than 300 cities to serve millions of users. We evaluate the Wi-Fi helped localization system in terms of service coverage, response time, and accuracy in different areas (e.g., office area vs. residential area) and different cities. We compared the accuracy of our localization system with that of two well-known companies, such as Apple's location services. Our proposed system demonstrated superior performance, outperforming other commercial localization systems. Additionally, the fingerprint dataset collected during this study will be publicly released to support further research.


  • Open Access

    Multi-Antenna Quantum Receiver: A Leap Beyond Angle Estimation Constraints

    by Zhaodian He, Fusang Zhang, Junqi Ma, Yuqi Su, Beihong Jin, Daqing Zhang, Yuechun Jiao, Lili Qiu, Jie Xiong

  • Open Access

    RF-AE: Single-site Arterial Elasticity Estimation Using UWB Signals

    by Zhi Wang, Beihong Jin, Yuhui Chen, Fusang Zhang, Siheng Li, Junqi Ma, Tao Gong, Yu Fu

    Arterial elasticity is the capability of the arteries to dilate and constrict in response to fluctuations in blood pressure as the heart circulates blood throughout the body, serving as an important indicator for assessing arterial health. However, conventional medical detection methods are often complex, costly, and require direct contact between the user's skin and the device, making them impractical for regular monitoring. In this paper, we propose a contactless single-site arterial elasticity assessment approach using ultra-wideband (UWB) signals, where we estimate the brachial-ankle pulse wave velocity, a key indicator of arterial health, by analyzing the UWB signals reflected off the back of a subject sitting still. Specifically, we first propose preprocessing methods to reduce noise in the received UWB signals, and then design a deep generative adversarial network to generate pulse wave signals from these UWB signals. The generated signals are of high quality and fidelity, exhibiting characteristics of vasoconstriction and vasodilation. Further, we analyze the pulse wave and extract the features related to arterial elasticity from the generated pulse waves. Finally, we employ random forest regression to predict pulse transit time and a body-height based method to estimate the length of the pulse transit path, so as to achieve single-site arterial elasticity assessment. We build the corresponding system named RF-AE and conduct extensive experiments to evaluate its performance. The experimental results show that RF-AE can accurately predict the arterial elasticity of users.


  • Open Access

    Hypnos: A Contactless Sleep Stage Monitoring System Using UWB Signals

    by Siheng Li, Beihong Jin, Fusang Zhang, Zhi Wang, Junqi Ma, Xiaoyong Ren, Haiqin Liu

    As a fundamental physiological process, sleep plays a vital role in human health. High-quality sleep requires a reasonable distribution of sleep duration over different sleep stages. Recently, contactless solutions have been used for in-home sleep stage monitoring via wireless signals as it enables monitoring daily sleep in a non-intrusive manner. However, various factors, such as the subject's physiological characteristics during sleep, the subject's health status, and even the sleep environment, pose challenges to wireless signal analysis. In this paper, we propose Hypnos, a contactless sleep monitoring system that identifies different sleep stages using an ultra-wideband (UWB) device. Hypnos enables automated bed localization and extracts signals containing coarse-grained body movements and fine-grained chest movements due to breathing and heartbeat from the subject, which acts as the preparation step for sleep staging. The key to our system is a seq2seq deep learning model, which adopts an attention-based sequence encoder to learn the patterns and transitions within and between sleep epochs and combines with contrastive learning to improve the generalizability of the encoder. Particularly, we incorporate sleep apnea detection as an auxiliary task into the model to reduce the interference of sleep apnea with sleep staging. Moreover, we design a two-step training for better adaptation of subjects with different severities of sleep disorders. We conduct extensive experiments on 100 subjects, including healthy individuals and patients with sleep disorders, and the experimental results show that Hypnos achieves excellent performance in multi-stage sleep classification (including 5-stage sleep classification), and outperforms other baseline methods.


  • Open Access

    Push the Limit of Highly Accurate Ranging on Commercial UWB Devices

    by Junqi Ma, Fusang Zhang, Beihong Jin, Chang Su, Siheng Li, Zhi Wang, Jiazhi Ni

    Ranging plays a crucial role in many wireless sensing applications. Among the wireless techniques employed for ranging, Ultra-Wideband (UWB) has received much attention due to its excellent performance and widespread integration into consumer-level electronics. However, the ranging accuracy of the current UWB systems is limited to the centimeter level due to bandwidth limitation, hindering their use for applications that require a very high resolution. This paper proposes a novel system that achieves sub-millimeter-level ranging accuracy on commercial UWB devices for the first time. Our approach leverages the fine-grained phase information of commercial UWB devices. To eliminate the phase drift, we design a fine-grained phase recovery method by utilizing the bi-directional messages in UWB two-way ranging. We further present a dual-frequency switching method to resolve phase ambiguity. Building upon this, we design and implement the ranging system on commercial UWB modules. Extensive experiments demonstrate that our system achieves a median ranging error of just 0.77 mm, reducing the error by 96.54% compared to the state-of-the-art method. We also present three real-life applications to showcase the fine-grained sensing capabilities of our system, including i) smart speaker control, ii) free-style user handwriting, and iii) 3D tracking for virtual-reality (VR) controllers.


  • Open Access

    UWB-enabled Sensing for Fast and Effortless Blood Pressure Monitoring

    by Zhi Wang, Beihong Jin, Fusang Zhang, Siheng Li, Junqi Ma

    Blood Pressure (BP) is a critical vital sign to assess cardiovascular health. However, existing cuff-based and wearable-based BP measurement methods require direct contact between the user's skin and the device, resulting in poor user experience and limited engagement for regular daily monitoring of BP. In this paper, we propose a contactless approach using Ultra-WideBand (UWB) signals for regular daily BP monitoring. To remove components of the received signals that are not related to the pulse waves, we propose two methods that utilize peak detection and principal component analysis to identify aliased and deformed parts. Furthermore, to extract BP-related features and improve the accuracy of BP prediction, particularly for hypertensive users, we construct a deep learning model that extracts features of pulse waves at different scales and identifies the different effects of features on BP. We build the corresponding BP monitoring system named RF-BP and conduct extensive experiments on both a public dataset and a self-built dataset. The experimental results show that RF-BP can accurately predict the BP of users and provide alerts for users with hypertension. Over the self-built dataset, the mean absolute error (MAE) and standard deviation (SD) for SBP are 6.5 mmHg and 6.1 mmHg, and the MAE and SD for DBP are 4.7 mmHg and 4.9 mmHg.


  • Open Access

    Embracing Consumer-level UWB-equipped Devices for Fine-grained Wireless Sensing

    by Fusang Zhang, Zhaoxin Chang, Jie Xiong, Junqi Ma, Jiazhi Ni, Wenbo Zhang, Beihong Jin, Daqing Zhang

    RF sensing has been actively exploited in the past few years to enable novel IoT applications. Among different wireless technologies, WiFi-based sensing is most popular owing to the pervasiveness of WiFi infrastructure. However, one critical issue associated with WiFi sensing is that the information required for sensing can not be obtained from consumer-level devices such as smartphones or smart watches. The commonly-seen WiFi devices in our everyday lives actually can not be utilized for sensing. Instead, dedicated hardware with a specific WiFi card (e.g., Intel 5300) needs to be used for WiFi sensing. This paper involves Ultra-Wideband (UWB) into the ecosystem of RF sensing and makes RF sensing work on consumer-level hardware such as smartphones and smart watches for the first time. We propose a series of methods to realize UWB sensing on consumer-level electronics without any hardware modification. By leveraging fine-grained human respiration monitoring as the application example, we demonstrate that the achieved performance on consumer-level electronics is comparable to that achieved using dedicated UWB hardware. We show that UWB sensing hosted on consumer-level electronics is able to achieve fine granularity, robustness against interference and also multi-target sensing, pushing RF sensing one step towards real-life adoption.