MHMaja Šuštar Habjan

Maja Šuštar Habjan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maja Šuštar Habjan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Review of the clinical electrooculogram - Part 1: Mechanism of the Light-Rise

    by Paul A. Constable, Lynne Loh, Maja Šuštar Habjan, Srikanta Kumar Padhy

    The clinical electrooculogram (EOG) is the sole clinical electrophysiological test for assessing the function of the retinal pigment epithelium (RPE). However, despite several lines of investigation, the complete mechanism of the response has evaded a comprehensive description. The standard model implicates the rod photoreceptors and a signaling molecule termed the ‘light-rise substance’ that binds to an apical membrane ‘light-rise receptor’ or is transported across the membrane to elevate intracellular calcium concentration. The identity of the calcium activated chloride channel in the basolateral membrane was thought to be bestrophin, given the association of mutations in the hbest1 gene with Best Vitelliform Macular Dystrophy. However, recent findings have implicated a member of the anoctamin family as the calcium activated chloride channel with bestrophin regulating intracellular calcium in conjunction with the L-type calcium channel. How the changes in intracellular calcium are manifested as well as how the interaction with light in the dark-adapted state gives rise to the slow-dark and -light damped oscillations are yet to be described fully. This review summarizes the cellular mechanisms of the RPE that have been implicated in the generation of the light-rise and describes the likely candidates for the light-rise substance. A companion paper provides a summary of the bestrophinopathies and possible clinical modifications to enhance the EOG’s clinical utility.

  • Open Access

    Review of the clinical electrooculogram - Part 2: the bestrophinopathies and modified protocols

    by Srikanta Kumar Padhy, Maja Šuštar Habjan, Paul A. Constable

    The light-rise of the electro-oculogram (EOG) is used as a clinical marker for a collection of disorders known as the ‘bestrophinopathies.’ This review provides an overview of these conditions including Best Vitelliform Macular Dystrophy (BVMD, Autosomal Recessive Bestrophinopathy (ARB), Adult Onset Vitelliform Macular Dystrophy (AVMD) and Autosomal Dominant Vitreoretinalchoriodopathy (ADVIRC) and potential future therapies. One drawback of the EOG is the time to administer the test and shortened protocols that have been developed to improve the clinical testing of the EOG which include incorporating measures during recordings of the ERG or shortening the period of dark and light adaptation. The companion paper summarizes the cellular mechanism of the EOG, and this review is focused on the clinical applications of the EOG.


  • Screening electro-oculography protocol as a part of full-field electroretinography

    by Paula Djukanovic, Martina Jarc Vidmar, Maja Sustar Habjan

    Purpose To simplify the electro-oculography (EOG) method and integrate it into the full-field electroretinogram (ffERG) protocol for screening purposes. Methods 20 control subjects and 5 patients with Best vitelliform macular dystrophy (BVMD) underwent EOG recording according to both the standard protocol and screening EOG protocol that was integrated as part of ffERG testing. Mean values of light peak-to-dark trough ratio (LP:DT ratio) were compared between both protocols using the Student’s t-test, sensitivity and specificity for the detection of RPE dysfunction were evaluated with ROC analysis and a survey on the difficulty of each protocol was completed by each subject. Results With the standard EOG mean LP:DT ratio was 2.67 ± 0.61 in controls and 1.12 ± 0.16 in BVMD patients (p < 0.001). With the screening protocol mean LP:DT ratio was 1.98 ± 0.33 in controls and 1.02 ± 0.14 in BVMD (p < 0.001). A comparison of LP:DT ratios showed significant difference between the standard and the screening protocol (p < 0.01 in controls; p = 0.02 in BVMD), however both protocols showed 100% sensitivity and 100% specificity for detection of BVMD. Patients stated that participation in the screening protocol was easier and less uncomfortable. Conclusions Screening EOG performed as part of ffERG gives comparable results to standard EOG, examination is patient-friendly, time saving and can be used as a preliminary test for the assessment of RPE function.


  • Slope between positive and negative ERG components in patients with open-angle glaucoma

    by Maja Sustar Habjan, Barbara Cvenkel

    Purpose To evaluate ERG morphology, in particular the slope between P50 and N95 components of the PERG, as well as between the b-wave and the photopic negative response (PhNR) of the light-adapted (LA) ERG in patients with retinal ganglion cell (RGC) dysfunction due to open-angle glaucoma. Methods The PERG and LA-ERG traces of 16 glaucoma patients and 21 age-similar controls were retrospectively analysed. The ERG signal between the peak of the positive component (P50 and b-wave) towards the negative component (N95 and PhNR) was described by a linear regression y = a + bx, where the parameter b indicated the steepness of the P50-N95 and b-PhNR slope. Results The P50-N95 slope was less steep in glaucoma patients (−0.079 ± 0.034 vs. −0.166 ± 0.050 in controls, p < 0.001), while the b-PhNR slope was not affected (−4.2 ± 2.1 vs. −4.4 ± 1.2, p = NS). The P50-N95 slope showed strong correlation with PhNR and N95 amplitude (r = −0.68 and −0.92, respectively; p < 0.001), while the b-PhNR slope correlated only with b-wave amplitude (r = −0.66, p < 0.001). Conclusions The P50-N95 slope is a sensitive indicator of RGC dysfunction in patients with open-angle glaucoma. A similar component of LA-ERG, the b-PhNR slope, is less affected by glaucomatous RGC dysfunction and probably originates from similar retinal mechanisms as the b-wave.


  • Top Cited Papers
    Open Access

    ISCEV standard for clinical pattern electroretinography (2024 update)

    by D. A. Thompson, M. Bach, J. J. McAnany, M. Šuštar Habjan, S. Viswanathan, A. G. Robson

    The pattern electroretinogram (PERG) is a localized retinal response evoked by a contrast-reversing pattern, usually a black and white checkerboard, which provides information about macular and retinal ganglion cell function. This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV; www.iscev.org) presents an updated and revised Standard for clinical PERG testing. This replaces the 2013 and all earlier versions. Minimum protocols for basic PERG stimuli, recording methods and reporting are specified, to promote consistency of methods for diagnosis and monitoring purposes, while responding to evolving clinical practices and technology. The main changes in the updated ISCEV Standard for clinical PERG include expanded guidance about large stimulus fields, stimulus parameters for simultaneous PERG and pattern visual evoked potential recording, baseline drift correction, and use of consistent ambient room lighting. These changes aim to provide a clinically relevant document about current practice which will facilitate good quality recordings and inter-laboratory comparisons.


  • Analysis of the slope between P50 and N95 waves of the large field pattern electroretinogram as an additional indicator of ganglion cell dysfunction

    by Maja Sustar Habjan, Jelka Brecelj, Marko Hawlina

    Aim Dysfunction of the retinal ganglion cells (RGC) can be detected by the pattern electroretinogram (PERG) as a reduction of the N95 amplitude, a decrease of the ratio between N95 and P50 amplitude and/or a shortening of P50 peak time. Additionally, the slope from the top of the P50 towards the N95 (P50–N95 slope) is less steep than in control subjects. The aim of the study was to quantitatively evaluate this slope in large field PERGs in controls and patients with RGC dysfunction due to optic neuropathy. Subjects and methods Large field (21.6°X27.8°) PERGs and optical coherence tomography (OCT) data from 30 eyes of the 30 patients with different types of clinically confirmed optic neuropathies, and with P50 amplitudes within normal limits and abnormal PERG N95 were retrospectively analysed and compared to 30 healthy eyes of 30 control subjects. The P50-N95 slope was analysed with a linear regression from 50 to 80 ms after the stimulus reversal. Results The patients with optic neuropathy exhibited a significant reduction of the N95 amplitude (p < 0.001) and N95/P50 ratio (p < 0.001), the P50 peak time was mildly shorter (p = 0.03). The P50–N95 slope was significantly less steep in eyes with optic neuropathies (− 0.089 ± 0.029 vs. − 0.220 ± 0.041, p < 0.001). Thickness of temporal RNFL and the P50–N95 slope appeared to be the most sensitive and specific parameters for detecting RGC dysfunction (AUC = 1.0). Conclusions The slope between the P50 and N95 waves of a large field PERG is considerably less steep in patients with RGC dysfunction and could thus be an efficient biomarker, particularly in the diagnosis of early or borderline cases.


  • Open Access

    Oxidative Stress in Antibiotic Toxic Optic Neuropathy Mimicking Acute LHON in a Patient with Exacerbation of Cystic Fibrosis

    by Lea Kovač, Marija Volk, Maja Šuštar Habjan, Marko Hawlina

    The striking similarity of disc edema without leakage on fluorescein angiography, which is pathognomonic of Leber hereditary optic neuropathy (LHON), was present in a patient with cystic fibrosis with antibiotic toxic optic neuropathy. This similarity suggested the common effect of oxidative stress on retinal ganglion cells in inherited mitochondrial and antibiotic optic neuropathies. We present the case of a patient with advanced cystic fibrosis on chronic antibiotic treatment who experienced a rapid painless bilateral visual decline over a course of a few weeks. At examination, his corrected visual acuity was reduced to 0.3 in both eyes, with dyschromatopsia and central scotoma. The appearance of the fundus resembled the typical clinical features of acute LHON with hyperemic optic discs and tortuous vessels with no dye leakage from the optic discs on fluorescein angiography. Ganglion cell layer loss was seen on optic coherence tomography, with all findings pointing to LHON. Genetic testing did not reveal any LHON-specific mutations. After extended genetic testing, a heterozygous variant c.209C>T in the OPA3 gene on chromosome 19, g.46032648G>A, classified as a variant of unknown significance, was also found. After discontinuing antibiotics and general improvements in his health, surprisingly, his visual function completely improved. Later, he also received a bilateral lung transplant that further improved his general condition, and his vision remained normal. Excluding LHON, the transient optic neuropathy in our patient could be mainly due to antibiotic toxicity of linezolid and ciprofloxacin, which have been linked to mitochondrial dysfunction and advanced cystic fibrosis with hypoxic status. We suggest the possibility that patients with cystic fibrosis may be more prone to developing mitochondrial optic neuropathy, especially with additional risk factors such as chronic antibiotic therapy, which affect mitochondrial function, and can perhaps serve as a model for LHON.


  • The role of visual electrodiagnostics in management of children with neurofibromatosis type 1

    by Manca Tekavčič Pompe, Nuška Pečarič Meglič, Maja Šuštar Habjan

    Purpose To evaluate the role of visual electrodiagnostic testing in children with neurofibromatosis type 1 (NF1) despite improved accessibility to magnetic resonance imaging (MRI). Methods The records from 39 children (78 eyes, 15 boys, 24 girls, average age at last visit of 11.5 ± 4.3 years, average follow-up time of 7.8 ± 3.9 years) with genetically confirmed NF1 were retrospectively analysed. They all underwent a thorough ophthalmological investigation, including age-appropriate visual acuity testing, anterior segment evaluation for Lisch nodules and a dilated fundus examination. If children were cooperative enough, colour vision was tested using the Hardy-Rand-Rittler test, visual fields were evaluated with Goldmann perimetry. All performed MRI of the brain and orbits as part of the standard of care protocol. Visual electrodiagnostics included electroretinography (ERG) and visual evoked potentials (VEP) using a standard protocol in older children, whereas with less cooperative children a modified protocol according to the Great Ormond Street Hospital (GOSH protocol) was used. Results The average visual acuity was 0.8 ± 0.3, colour vision was abnormal in 6%, perimetry in 8%, Lisch nodules were present in 62%, and the optic disc was pale in 66% of all eyes. Plexiform neurofibroma of the eyelid/orbit was present in 4%. Optic pathway glioma (OPG) was detected with MRI in 22 (57%) and in 6/22 treatment was indicated. Other intracranial NF1-related lesions were documented in 70% of children. VEP were abnormal in 16/39 of all children with NF1 (41%) comprising 14/22 (65%) of children with confirmed OPG and 2/17 (12%) of children without OPG. All full-field and pattern ERG responses were within normal limits. All individual VEP results are described and three cases from this cohort of children are presented in detail to illustrate the importance of VEP testing. In Case 1, VEP abnormality suggested subsequent MRI of the brain under general anaesthesia, which was otherwise contraindicated according to normal clinical findings and his young age. In Cases 2 and 3, VEP provided more precise functional information during the follow-up of OPG, while other psychophysical tests remained unchanged. Conclusions Electrodiagnostics has multifactorial role and importance in children with NF1, either when visual pathway function is impaired in young children, even before MRI under general anaesthesia and other psychophysical tests can be performed, as well as for a more precise monitoring of the visual pathway function before potential treatment of OPG, or after it, to evaluate its success.


  • ON- and OFF-response of the photopic electroretinogram in relation to stimulus characteristics

    by Maja Sustar, Marko Hawlina, Jelka Brecelj

    The aim of this study was to explore the effect of stimulus duration, stimulus intensity, stimulus wavelength and background luminance on the amplitude and waveform of the ON- (b-wave) and OFF- (d-wave) response of the photopic ERG. The following parameters were used in this study: stimulus duration from 5 to 200 ms, the flash intensities from 0.4 to 2.1 log cd s/m2, the background luminance from 20 to 50 cd/m2 and stimulus wavelengths 460, 508 and 667 nm. Prolonging the stimulus duration from 75 to 200 ms did not influence the amplitudes of a-, b- and d-waves significantly. Higher stimulus intensities (1.9 log cd s/m2) broadened the b-wave and increased variability of its implicit time. With a brighter background (50 cd/m2) the b-wave did not broaden and its optimal amplitude was preserved. Stimuli of longer wavelengths (667 nm) significantly reduced the d-wave amplitude. Our results suggest that high intensities and longer wavelengths (red) may not be suitable stimulus parameters in the routine clinical ON- and OFF-response recording.