Tiberiu Burlacu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tiberiu Burlacu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Danny Lathouwers
Department of Radiation, Science and Technology, Delft University of Technology, section Medical Physics and Technology, Mekelweg 15, Delft, The Netherlands
3 shared publications - Zoltán Perkó
Radiation Science and Technology, Delft University of Technology, Reactor Institute Delft, Mekelweg 15, Delft, 2629 JB, NETHERLANDS
3 shared publications Danny Lathouwers
Faculty of Applied Sciences Delft University of Technology Delft The Netherlands
1 shared publicationMischa Hoogeman
Faculty of Applied Sciences Delft University of Technology Delft The Netherlands
1 shared publication- Mischa S. Hoogeman
Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands; Department of Medical Physics & Informatics, HollandPTC, Delft, The Netherlands
1 shared publication Zoltán Perkó
Faculty of Applied Sciences Delft University of Technology Delft The Netherlands
1 shared publication
Latest Publications
- Open Access
- 10 March 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (6) , 065011
A deep learning model for inter-fraction head and neck anatomical changes in proton therapy
Objective. To assess the performance of a probabilistic deep learning based algorithm for predicting inter-fraction anatomical changes in head and neck patients. Approach. A probabilistic daily anatomy model (DAM) for head and neck patients DAM (DAMHN) is built on the variational autoencoder architecture. The model approximates the generative joint conditional probability distribution of the repeat computed tomography (rCT) images and their corresponding masks on the planning CT images (pCT) and their masks. The model outputs deformation vector fields, which are used to produce possible rCTs and associated masks. The dataset is composed of 93 patients (i.e. 315 pCT–rCT pairs), 9 (i.e. 27 pairs) of which were set aside for final testing. The performance of the model is assessed based on the reconstruction accuracy and the generative performance for the set aside patients. Main results. The model achieves a DICE score of 0.83 and an image similarity score normalized cross-correlation of 0.60 on the test set. The generated parotid glands, spinal cord and constrictor muscle volume change distributions and center of mass shift distributions were also assessed. For all organs, the medians of the distributions are close to the true ones, and the distributions are broad enough to encompass the real observed changes. Moreover, the generated images display anatomical changes in line with the literature reported ones, such as the medial shifts of the parotids glands. Significance. DAMHN is capable of generating realistic anatomies observed during the course of the treatment and has applications in anatomical robust optimization, treatment planning based on plan library approaches and robustness evaluation against inter-fractional changes.
- 10 March 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (6) , 065011
Open AccessA deep learning model for inter-fraction head and neck anatomical changes in proton therapy
Objective. To assess the performance of a probabilistic deep learning based algorithm for predicting inter-fraction anatomical changes in head and neck patients. Approach. A probabilistic daily anatomy model (DAM) for head and neck patients DAM (DAMHN) is built on the variational autoencoder architecture. The model approximates the generative joint conditional probability distribution of the repeat computed tomography (rCT) images and their corresponding masks on the planning CT images (pCT) and their masks. The model outputs deformation vector fields, which are used to produce possible rCTs and associated masks. The dataset is composed of 93 patients (i.e. 315 pCT–rCT pairs), 9 (i.e. 27 pairs) of which were set aside for final testing. The performance of the model is assessed based on the reconstruction accuracy and the generative performance for the set aside patients. Main results. The model achieves a DICE score of 0.83 and an image similarity score normalized cross-correlation of 0.60 on the test set. The generated parotid glands, spinal cord and constrictor muscle volume change distributions and center of mass shift distributions were also assessed. For all organs, the medians of the distributions are close to the true ones, and the distributions are broad enough to encompass the real observed changes. Moreover, the generated images display anatomical changes in line with the literature reported ones, such as the medial shifts of the parotids glands. Significance. DAMHN is capable of generating realistic anatomies observed during the course of the treatment and has applications in anatomical robust optimization, treatment planning based on plan library approaches and robustness evaluation against inter-fractional changes.
- Open Access
A deep learning model for inter-fraction head and neck anatomical changes
Objective: To assess the performance of a probabilistic deep learning based algorithm for predicting inter-fraction anatomical changes in head and neck patients. Approach: A probabilistic daily anatomy model for head and neck patients $(\mathrm{DAM}_{\mathrm{HN}})$ is built on the variational autoencoder architecture. The model approximates the generative joint conditional probability distribution of the repeat computed tomography (rCT) images and their corresponding masks on the planning CT images (pCT) and their masks. The model outputs deformation vector fields, which are used to produce possible rCTs and associated masks. The dataset is composed of 93 patients (i.e., 367 pCT - rCT pairs), 9 (i.e., 37 pairs) of which were set aside for final testing. The performance of the model is assessed based on the reconstruction accuracy and the generative performance for the set aside patients. Main results: The model achieves a DICE score of 0.92 and an image similarity score of 0.65 on the test set. The generated parotid glands volume change distributions and center of mass shift distributions were also assessed. For both, the medians of the distributions are close to the true ones, and the distributions are broad enough to encompass the real observed changes. Moreover, the generated images display anatomical changes in line with the literature reported ones, such as the medial shifts of the parotids glands. Significance: $(\mathrm{DAM}_{\mathrm{HN}})$ is capable of generating realistic anatomies observed during the course of the treatment and has applications in anatomical robust optimization, treatment planning based on plan library approaches and robustness evaluation against inter-fractional changes.Open AccessA deep learning model for inter-fraction head and neck anatomical changes
Objective: To assess the performance of a probabilistic deep learning based algorithm for predicting inter-fraction anatomical changes in head and neck patients. Approach: A probabilistic daily anatomy model for head and neck patients $(\mathrm{DAM}_{\mathrm{HN}})$ is built on the variational autoencoder architecture. The model approximates the generative joint conditional probability distribution of the repeat computed tomography (rCT) images and their corresponding masks on the planning CT images (pCT) and their masks. The model outputs deformation vector fields, which are used to produce possible rCTs and associated masks. The dataset is composed of 93 patients (i.e., 367 pCT - rCT pairs), 9 (i.e., 37 pairs) of which were set aside for final testing. The performance of the model is assessed based on the reconstruction accuracy and the generative performance for the set aside patients. Main results: The model achieves a DICE score of 0.92 and an image similarity score of 0.65 on the test set. The generated parotid glands volume change distributions and center of mass shift distributions were also assessed. For both, the medians of the distributions are close to the true ones, and the distributions are broad enough to encompass the real observed changes. Moreover, the generated images display anatomical changes in line with the literature reported ones, such as the medial shifts of the parotids glands. Significance: $(\mathrm{DAM}_{\mathrm{HN}})$ is capable of generating realistic anatomies observed during the course of the treatment and has applications in anatomical robust optimization, treatment planning based on plan library approaches and robustness evaluation against inter-fractional changes. - Open Access
- 30 July 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165003
Yet anOther Dose Algorithm (YODA) for independent computations of dose and dose changes due to anatomical changes
Objective. To assess the viability of a physics-based, deterministic and adjoint-capable algorithm for performing treatment planning system independent dose calculations and for computing dosimetric differences caused by anatomical changes. Approach. A semi-numerical approach is employed to solve two partial differential equations for the proton phase-space density which determines the deposited dose. Lateral hetereogeneities are accounted for by an optimized (Gaussian) beam splitting scheme. Adjoint theory is applied to approximate the change in the deposited dose caused by a new underlying patient anatomy. Main results. The dose engine’s accuracy was benchmarked through three-dimensional gamma index comparisons against Monte Carlo simulations done in TOPAS. For a lung test case, the worst passing rate with (1 mm, 1%, 10% dose cut-off) criteria is 94.55%. The effect of delivering treatment plans on repeat CTs was also tested. For non-robustly optimized plans the adjoint component was accurate to 5.7% while for a robustly optimized plan it was accurate to 4.8%. Significance. Yet anOther Dose Algorithm is capable of accurate dose computations in both single and multi spot irradiations when compared to TOPAS. Moreover, it is able to compute dosimetric differences due to anatomical changes with small to moderate errors thereby facilitating its use for patient-specific quality assurance in online adaptive proton therapy.
- 30 July 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165003
Open AccessYet anOther Dose Algorithm (YODA) for independent computations of dose and dose changes due to anatomical changes
Objective. To assess the viability of a physics-based, deterministic and adjoint-capable algorithm for performing treatment planning system independent dose calculations and for computing dosimetric differences caused by anatomical changes. Approach. A semi-numerical approach is employed to solve two partial differential equations for the proton phase-space density which determines the deposited dose. Lateral hetereogeneities are accounted for by an optimized (Gaussian) beam splitting scheme. Adjoint theory is applied to approximate the change in the deposited dose caused by a new underlying patient anatomy. Main results. The dose engine’s accuracy was benchmarked through three-dimensional gamma index comparisons against Monte Carlo simulations done in TOPAS. For a lung test case, the worst passing rate with (1 mm, 1%, 10% dose cut-off) criteria is 94.55%. The effect of delivering treatment plans on repeat CTs was also tested. For non-robustly optimized plans the adjoint component was accurate to 5.7% while for a robustly optimized plan it was accurate to 4.8%. Significance. Yet anOther Dose Algorithm is capable of accurate dose computations in both single and multi spot irradiations when compared to TOPAS. Moreover, it is able to compute dosimetric differences due to anatomical changes with small to moderate errors thereby facilitating its use for patient-specific quality assurance in online adaptive proton therapy.
- Open Access
- 2 January 2023
- Published by Taylor & Francis in Journal of Computational and Theoretical Transport
- Vol. 52 (1) , 1-41
A Deterministic Adjoint-Based Semi-Analytical Algorithm for Fast Response Change Computations in Proton Therapy
In this paper we propose a solution to the need for a fast particle transport algorithm in Online Adaptive Proton Therapy capable of cheaply, but accurately computing the changes in patient dose metrics as a result of changes in the system parameters. We obtain the proton phase-space density through the product of the numerical solution to the one-dimensional Fokker-Planck equation and the analytical solution to the Fermi-Eyges equation. Moreover, a corresponding adjoint system was derived and solved for the adjoint flux. The proton phase-space density together with the adjoint flux and the metric (chosen as the energy deposited by the beam in a variable region of interest) allowed assessing the accuracy of our algorithm to different perturbation ranges in the system parameters and regions of interest. The algorithm achieved negligible errors ( ) for small Hounsfield unit (HU) perturbation ranges (–40 HU to 40 HU) and small to moderate errors (3% to 17%) – in line with the well-known limitation of adjoint approaches – for large perturbation ranges (–400 HU to 400 HU) in the case of most clinical interest where the region of interest surrounds the Bragg peak. Given these results coupled with the capability of further improving the timing performance it can be concluded that our algorithm presents a viable solution for the specific purpose of Online Adaptive Proton Therapy.- 2 January 2023
- Published by Taylor & Francis in Journal of Computational and Theoretical Transport
- Vol. 52 (1) , 1-41
Open AccessA Deterministic Adjoint-Based Semi-Analytical Algorithm for Fast Response Change Computations in Proton Therapy
In this paper we propose a solution to the need for a fast particle transport algorithm in Online Adaptive Proton Therapy capable of cheaply, but accurately computing the changes in patient dose metrics as a result of changes in the system parameters. We obtain the proton phase-space density through the product of the numerical solution to the one-dimensional Fokker-Planck equation and the analytical solution to the Fermi-Eyges equation. Moreover, a corresponding adjoint system was derived and solved for the adjoint flux. The proton phase-space density together with the adjoint flux and the metric (chosen as the energy deposited by the beam in a variable region of interest) allowed assessing the accuracy of our algorithm to different perturbation ranges in the system parameters and regions of interest. The algorithm achieved negligible errors ( ) for small Hounsfield unit (HU) perturbation ranges (–40 HU to 40 HU) and small to moderate errors (3% to 17%) – in line with the well-known limitation of adjoint approaches – for large perturbation ranges (–400 HU to 400 HU) in the case of most clinical interest where the region of interest surrounds the Bragg peak. Given these results coupled with the capability of further improving the timing performance it can be concluded that our algorithm presents a viable solution for the specific purpose of Online Adaptive Proton Therapy.