DTDuong-Thuy Tran

Duong-Thuy Tran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Duong-Thuy Tran has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Ming-Long Yeh

    Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan

    2 shared publications
  • Fang-Hsu Chen

    Department of Biomedical Engineering, National Cheng Kung University, No. 1, Daxue Road, East District, Tainan701, Taiwan

    1 shared publication
  • Fang-Hsu Chen

    Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan

    1 shared publication
  • Guan-Lin Wu

    Department of Biomedical Engineering, National Cheng Kung University, No. 1, Daxue Road, East District, Tainan701, Taiwan

    1 shared publication
  • I-Hsuan Lin

    Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan

    1 shared publication
  • Lemmuel L. Tayo

    School of Chemical, Biological, and Materials Engineering and Sciences, Mapúa University, Manila 1002, Philippines

    1 shared publication

Latest Publications

  • Open Access

    Evaluation of Articular Cartilage Regeneration Properties of Decellularized Cartilage Powder/Modified Hyaluronic Acid Hydrogel Scaffolds

    by Paula Carmela O. Ching, Fang-Hsu Chen, I-Hsuan Lin, Duong-Thuy Tran, Lemmuel L. Tayo, Ming-Long Yeh

    The articular cartilage has poor intrinsic healing potential, hence, imposing a great challenge for articular cartilage regeneration in osteoarthritis. Tissue regeneration by scaffolds and bioactive materials has provided a healing potential for degenerated cartilage. In this study, decellularized cartilage powder (DCP) and hyaluronic acid hydrogel modified by aldehyde groups and methacrylate (AHAMA) were fabricated and evaluated in vitro for efficacy in articular cartilage regeneration. In vitro tests such as cell proliferation, cell viability, and cell migration showed that DCP/AHAMA has negligible cytotoxic effects. Furthermore, it could provide an enhanced microenvironment for infrapatellar fat pad stem cells (IFPSCs). Mechanical property tests of DCP/AHAMA showed suitable adhesive and compressive strength. IFPSCs under three-dimensional (3D) culture in DCP/AMAHA were used to assess their ability to proliferate and differentiate into chondrocytes using normal and chondroinductive media. Results exhibited increased gene expression of COL2 and ACN and decreased COL1 expression. DCP/AHAMA provides a microenvironment that recapitulates the biomechanical properties of the native cartilage, promotes chondrogenic differentiation, blocks hypertrophy, and demonstrates applicability for cartilage tissue engineering and the potential for clinical biomedical applications.


  • Influence of Spin Coating and Dip Coating with Gelatin/Hydroxyapatite for Bioresorbable Mg Alloy Orthopedic Implants: In Vitro and In Vivo Studies

    by Duong-Thuy Tran, Fang-Hsu Chen, Guan-Lin Wu, Paula Carmela O. Ching, Ming-Long Yeh

    Suitable biomechanical properties, good biocompatibility, and osteoconductivity of a degradable magnesium (Mg) alloy make it a potential material for orthopedic implants. The main limitation of Mg is its high corrosion rate in the human body. Surface modification is necessary to improve the Mg corrosion resistance. In this work, a polymeric layer of gelatin/nanohydroxyapatite (Gel/nHA) was coated on a ZK60 Mg alloy by dip coating and spin coating to test the corrosion resistance and biocompatibility in vitro and in vivo. The results from the in vitro test revealed that the coated groups reduced the corrosion rate with the corrosion current density by 59 and 81%, from 31.22 to 12.83 μA/cm2 and 5.83 μA/cm2 in the spin coating and dip coating groups, respectively. The dip coating group showed better corrosion resistance than the spin coating group with the lowest released hydrogen content (17.5 mL) and lowest pH value (8.23) and reducing the current density by 45%. In vitro, the relative growth rate was over 75% in all groups tested with MG63, demonstrating that the Mg substrate and coating materials were within the safety range. The dip coating and spin coating groups enhanced the cell proliferation with significantly higher OD values (3.3, 3.0, and 2.5, respectively) and had better antihemolysis and antiplatelet adhesion abilities than the uncoated group. The two coating methods showed no difference in the cellular response, cell migration, hemolysis, and platelet adhesion test. In in vivo tests in rats, the dip coating group also showed a higher corrosion resistance with a lower corrosion rate and mass loss than the spin coating group. In addition, the blood biochemistry and histopathology results indicated that all materials used in this study were biocompatible with living subjects. The present research confirmed that the two methods have no noticeable difference in cell and organ response but the corrosion resistance of dip coating was higher than that of spin coating either in vitro or in vivo.