Fang-Hsu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fang-Hsu Chen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ming-Long Yeh
Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
2 shared publications Cheng-Han Yang
Department of Chemistry, National Chung Hsing University, Taichung City 40227, Taiwan
1 shared publicationChun-Yen Cheng
Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan
1 shared publication- Duong-Thuy Tran
Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan
1 shared publication - I-Chung Lu
Department of Chemistry National Chung Hsing University Taichung Taiwan
1 shared publication I-Hsuan Lin
Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan
1 shared publication
Latest Publications
- Open Access
- 6 September 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (37) , 14867-14876
High-Resolution Intact Protein Analysis via Phase-Modulated, Stepwise Frequency Scan Ion Trap Mass Spectrometry
Mass spectrometry (MS) using an electron multiplier for intact protein analysis remains limited. Because of the massive size and complex structure of proteins, the slow flight speed of their ions results in few secondary electrons and thus low detection sensitivity and poor spectral resolution. Thus, we present a compact ion trap-mass spectrometry approach to directly detect ion packets and obtain the high-resolution molecular signature of proteins. The disturbances causing deviations of ion motion and mass conversion have been clarified in advance. The radio frequency waveform used to manipulate ions is proposed to be a sequence of constant-frequency steps, interconnected by short time-outs, resulting in least dispersive distortion. Furthermore, more such constant-phase conjunctions are arranged in each step to compensate for fluctuations resulting from defects in the system and operation. In addition, two auxiliary pulses are generated in the right phase of each step to select ions of a specific secular state to detect one clean and sharp spectral line.This study demonstrates a top-down approach for the MS measurement of cytochrome C molecules, resulting in a spectral profile of the protein in its natural state at a resolution of 20 Da. Additionally, quick MS scans of other proteins were performed.
- 6 September 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (37) , 14867-14876
Open AccessHigh-Resolution Intact Protein Analysis via Phase-Modulated, Stepwise Frequency Scan Ion Trap Mass Spectrometry
Mass spectrometry (MS) using an electron multiplier for intact protein analysis remains limited. Because of the massive size and complex structure of proteins, the slow flight speed of their ions results in few secondary electrons and thus low detection sensitivity and poor spectral resolution. Thus, we present a compact ion trap-mass spectrometry approach to directly detect ion packets and obtain the high-resolution molecular signature of proteins. The disturbances causing deviations of ion motion and mass conversion have been clarified in advance. The radio frequency waveform used to manipulate ions is proposed to be a sequence of constant-frequency steps, interconnected by short time-outs, resulting in least dispersive distortion. Furthermore, more such constant-phase conjunctions are arranged in each step to compensate for fluctuations resulting from defects in the system and operation. In addition, two auxiliary pulses are generated in the right phase of each step to select ions of a specific secular state to detect one clean and sharp spectral line.This study demonstrates a top-down approach for the MS measurement of cytochrome C molecules, resulting in a spectral profile of the protein in its natural state at a resolution of 20 Da. Additionally, quick MS scans of other proteins were performed.
- Open Access
- 27 July 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (31) , 33629-33642
Evaluation of Articular Cartilage Regeneration Properties of Decellularized Cartilage Powder/Modified Hyaluronic Acid Hydrogel Scaffolds
The articular cartilage has poor intrinsic healing potential, hence, imposing a great challenge for articular cartilage regeneration in osteoarthritis. Tissue regeneration by scaffolds and bioactive materials has provided a healing potential for degenerated cartilage. In this study, decellularized cartilage powder (DCP) and hyaluronic acid hydrogel modified by aldehyde groups and methacrylate (AHAMA) were fabricated and evaluated in vitro for efficacy in articular cartilage regeneration. In vitro tests such as cell proliferation, cell viability, and cell migration showed that DCP/AHAMA has negligible cytotoxic effects. Furthermore, it could provide an enhanced microenvironment for infrapatellar fat pad stem cells (IFPSCs). Mechanical property tests of DCP/AHAMA showed suitable adhesive and compressive strength. IFPSCs under three-dimensional (3D) culture in DCP/AMAHA were used to assess their ability to proliferate and differentiate into chondrocytes using normal and chondroinductive media. Results exhibited increased gene expression of COL2 and ACN and decreased COL1 expression. DCP/AHAMA provides a microenvironment that recapitulates the biomechanical properties of the native cartilage, promotes chondrogenic differentiation, blocks hypertrophy, and demonstrates applicability for cartilage tissue engineering and the potential for clinical biomedical applications.
- 27 July 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (31) , 33629-33642
Open AccessEvaluation of Articular Cartilage Regeneration Properties of Decellularized Cartilage Powder/Modified Hyaluronic Acid Hydrogel Scaffolds
The articular cartilage has poor intrinsic healing potential, hence, imposing a great challenge for articular cartilage regeneration in osteoarthritis. Tissue regeneration by scaffolds and bioactive materials has provided a healing potential for degenerated cartilage. In this study, decellularized cartilage powder (DCP) and hyaluronic acid hydrogel modified by aldehyde groups and methacrylate (AHAMA) were fabricated and evaluated in vitro for efficacy in articular cartilage regeneration. In vitro tests such as cell proliferation, cell viability, and cell migration showed that DCP/AHAMA has negligible cytotoxic effects. Furthermore, it could provide an enhanced microenvironment for infrapatellar fat pad stem cells (IFPSCs). Mechanical property tests of DCP/AHAMA showed suitable adhesive and compressive strength. IFPSCs under three-dimensional (3D) culture in DCP/AMAHA were used to assess their ability to proliferate and differentiate into chondrocytes using normal and chondroinductive media. Results exhibited increased gene expression of COL2 and ACN and decreased COL1 expression. DCP/AHAMA provides a microenvironment that recapitulates the biomechanical properties of the native cartilage, promotes chondrogenic differentiation, blocks hypertrophy, and demonstrates applicability for cartilage tissue engineering and the potential for clinical biomedical applications.