Eduardo J. Salazar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Eduardo J. Salazar has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Mauro Jurado
Instituto de Energía Eléctrica, Universidad Nacional de San Juan–Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), San Juan 5400, Argentina
4 shared publications - Mauricio E. Samper
Institute of Electrical Energy (IEE), National University of San Juan, National Scientific and Technical Research Council (CONICET), San Juan 5400, Argentina
3 shared publications - Gabriel Salazar Pérez
Departamento de Energía Eléctrica, Escuela Politécnica Nacional, Quito 170525, Ecuador
2 shared publications - Alejandro Fernandez-Benages1 shared publication
- Ali Agga
Mohammed V University in Rabat
1 shared publication - Claudio Roa
Departamento de Ingeniería Eléctrica, Facultad de Ingeniería, Universidad de Concepción. Chile. s:
1 shared publication
Latest Publications
- Open Access
- 2 November 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 158 (1) , 37
Voltage Ride-Through Assessment of a Grid-Following PV Plant in the IEEE 13-Node Unbalanced Feeder Under Grid-Connected and Islanded Conditions
This paper assesses the voltage ride-through (VRT) performance of a 1 MW grid-following photovoltaic (PV) plant connected to the IEEE 13-node unbalanced distribution feeder. Unbalanced RMS simulations in DIgSILENT PowerFactory 2024 SP5A (x64) consider single-phase-to-ground, phase-to-phase, and three-phase faults at the point of common coupling, as well as intentional islanding supported by a 3.5 MVA synchronous diesel generator. Under grid-connected operation, the PV plant remains connected for all simulated faults; the symmetrical three-phase case satisfies the Category-B ARCONEL-001/24 VRT envelope, while the asymmetric cases reveal phase-dependent behavior and temporary healthy-phase overvoltages. During islanding, the synchronous generator establishes the voltage and frequency reference, allowing the GFL PV plant to recover stable operation. The island frequency peaks at 60.929 Hz and settles near 60.664 Hz, both within the 59–61 Hz unlimited-operation band used as a regulatory reference. The results emphasize the importance of unbalanced modeling and grid-forming capability in inverter-rich distribution networks.
- 2 November 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 158 (1) , 37
Open AccessVoltage Ride-Through Assessment of a Grid-Following PV Plant in the IEEE 13-Node Unbalanced Feeder Under Grid-Connected and Islanded Conditions
This paper assesses the voltage ride-through (VRT) performance of a 1 MW grid-following photovoltaic (PV) plant connected to the IEEE 13-node unbalanced distribution feeder. Unbalanced RMS simulations in DIgSILENT PowerFactory 2024 SP5A (x64) consider single-phase-to-ground, phase-to-phase, and three-phase faults at the point of common coupling, as well as intentional islanding supported by a 3.5 MVA synchronous diesel generator. Under grid-connected operation, the PV plant remains connected for all simulated faults; the symmetrical three-phase case satisfies the Category-B ARCONEL-001/24 VRT envelope, while the asymmetric cases reveal phase-dependent behavior and temporary healthy-phase overvoltages. During islanding, the synchronous generator establishes the voltage and frequency reference, allowing the GFL PV plant to recover stable operation. The island frequency peaks at 60.929 Hz and settles near 60.664 Hz, both within the 59–61 Hz unlimited-operation band used as a regulatory reference. The results emphasize the importance of unbalanced modeling and grid-forming capability in inverter-rich distribution networks.
- Open Access
- 22 October 2026
- Published by Elsevier in Energy and Buildings
- Vol. 374
Sequential aggregation of building demand flexibility: An occupancy- and service-aware framework
- 22 October 2026
- Published by Elsevier in Energy and Buildings
- Vol. 374
Open AccessSequential aggregation of building demand flexibility: An occupancy- and service-aware framework
- 10 August 2026
- Published by Springer Nature
- p. 3-19
Reinforcement Learning-Assisted Evolutionary Optimization for Distribution Network Operational Planning
- 10 August 2026
- Published by Springer Nature
- p. 3-19
Reinforcement Learning-Assisted Evolutionary Optimization for Distribution Network Operational Planning
- Open Access
- 30 May 2026
- Published by Elsevier in SSRN Electronic Journal
Techno-Economic Assessment of Fixed-Tilt Photovoltaic Design Under DC/AC Ratio and Inverter Clipping Constraints
The economic design of fixed-tilt photovoltaic (PV) plants depends on the coupling between array geometry, inverter saturation, installed direct-current capacity, and cash-flow structure. This study develops an hourly techno-economic framework to jointly optimize fixed tilt angle and DC/AC ratio for three grid-connected PV archetypes: residential prosumer, commercial rooftop, and utility-scale systems. The technical model combines solar position, plane-of-array transposition, cell-temperature correction, balance-of-system losses, inverter efficiency, clipping, and thermal derating. The financial model converts annual AC energy into 25-year equity value using capital expenditure, O&M, debt amortization, depreciation, tariff escalation, and module degradation. The design grid covers tilt angles from 0° to 22° and DC/AC ratios from 1.05 to 1.49. Recommended designs must satisfy tilt ≥8°, performance ratio ≥84%, and clipping-related curtailment ≤2%. After applying these filters, preferred designs converge to 8° tilt with DC/AC ratios of 1.23, 1.29, and 1.27 for the residential, commercial, and utility cases, respectively. The utility-scale recommended design yields 87.14 GWh in year 1, 40.64 MUSD NPV, 23.72% IRR, 0.0445 USD/kWh LCOE, 84.94% PR, and 1.84% curtailment.
- 30 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTechno-Economic Assessment of Fixed-Tilt Photovoltaic Design Under DC/AC Ratio and Inverter Clipping Constraints
The economic design of fixed-tilt photovoltaic (PV) plants depends on the coupling between array geometry, inverter saturation, installed direct-current capacity, and cash-flow structure. This study develops an hourly techno-economic framework to jointly optimize fixed tilt angle and DC/AC ratio for three grid-connected PV archetypes: residential prosumer, commercial rooftop, and utility-scale systems. The technical model combines solar position, plane-of-array transposition, cell-temperature correction, balance-of-system losses, inverter efficiency, clipping, and thermal derating. The financial model converts annual AC energy into 25-year equity value using capital expenditure, O&M, debt amortization, depreciation, tariff escalation, and module degradation. The design grid covers tilt angles from 0° to 22° and DC/AC ratios from 1.05 to 1.49. Recommended designs must satisfy tilt ≥8°, performance ratio ≥84%, and clipping-related curtailment ≤2%. After applying these filters, preferred designs converge to 8° tilt with DC/AC ratios of 1.23, 1.29, and 1.27 for the residential, commercial, and utility cases, respectively. The utility-scale recommended design yields 87.14 GWh in year 1, 40.64 MUSD NPV, 23.72% IRR, 0.0445 USD/kWh LCOE, 84.94% PR, and 1.84% curtailment.
- Open Access
- 23 September 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 77 (1) , 9
Impact of Distributed Generation Integration on Protection Devices: A Case Study in the CIGRE European Medium Voltage Network
This study examines the impact of Inverter-Based Distributed Generators (IIDGs) on short-circuit currents detected by the main relay at the head of a radial feeder. It highlights how changes in fault currents induced by these inverter technologies can significantly affect the effectiveness and reliability of network protection systems. Key variables, such as the level of IIDGs penetration and the relative location of faults with respect to the relay, have been identified as influential factors. The significance of these findings lies in their contribution to a deeper understanding of how inverter fault responses and the integration of IIDGs alter fault currents. To mitigate the adverse effects associated with the insertion of IIDGs, a fault-detection and tripping strategy based on the inverse-time overcurrent curve is proposed. The suggested strategies not only improve fault detection accuracy but also ensure an appropriate response to variations in network conditions.
- 23 September 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 77 (1) , 9
Open AccessImpact of Distributed Generation Integration on Protection Devices: A Case Study in the CIGRE European Medium Voltage Network
This study examines the impact of Inverter-Based Distributed Generators (IIDGs) on short-circuit currents detected by the main relay at the head of a radial feeder. It highlights how changes in fault currents induced by these inverter technologies can significantly affect the effectiveness and reliability of network protection systems. Key variables, such as the level of IIDGs penetration and the relative location of faults with respect to the relay, have been identified as influential factors. The significance of these findings lies in their contribution to a deeper understanding of how inverter fault responses and the integration of IIDGs alter fault currents. To mitigate the adverse effects associated with the insertion of IIDGs, a fault-detection and tripping strategy based on the inverse-time overcurrent curve is proposed. The suggested strategies not only improve fault detection accuracy but also ensure an appropriate response to variations in network conditions.
- 21 March 2024
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 133
Demand response model: A cooperative-competitive multi-agent reinforcement learning approach
- 21 March 2024
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 133
Demand response model: A cooperative-competitive multi-agent reinforcement learning approach
- Open Access
Day-Ahead Operational Planning for DisCos Based on Demand Response Flexibility and Volt/Var Control
Considering the integration of distributed energy resources (DER) such as distributed generation, demand response, and electric vehicles, day-ahead scheduling plays a significant role in the operation of active distribution systems. Therefore, this article proposes a comprehensive methodology for the short-term operational planning of a distribution company (DisCo), aiming to minimize the total daily operational cost. The proposed methodology integrates on-load tap changers, capacitor banks, and flexible loads participating in demand response (DR) to reduce losses and manage congestion and voltage violations, while considering the costs associated with the operation and use of controllable resources. Furthermore, to forecast PV output and load demand behind the meter at the MV/LV distribution transformer level, a short-term net load forecasting model using deep learning techniques has been incorporated. The proposed scheme is solved through an efficient two-stage strategy based on genetic algorithms and dynamic programming. Numerical results based on the modified IEEE 13-node distribution system and a typical 37-node Latin American system validate the effectiveness of the proposed methodology. The obtained results verify that, through the proposed methodology, the DisCo can effectively schedule its installations and DR to minimize the total operational cost while reducing losses and robustly managing voltage and congestion issues.
Open AccessDay-Ahead Operational Planning for DisCos Based on Demand Response Flexibility and Volt/Var Control
Considering the integration of distributed energy resources (DER) such as distributed generation, demand response, and electric vehicles, day-ahead scheduling plays a significant role in the operation of active distribution systems. Therefore, this article proposes a comprehensive methodology for the short-term operational planning of a distribution company (DisCo), aiming to minimize the total daily operational cost. The proposed methodology integrates on-load tap changers, capacitor banks, and flexible loads participating in demand response (DR) to reduce losses and manage congestion and voltage violations, while considering the costs associated with the operation and use of controllable resources. Furthermore, to forecast PV output and load demand behind the meter at the MV/LV distribution transformer level, a short-term net load forecasting model using deep learning techniques has been incorporated. The proposed scheme is solved through an efficient two-stage strategy based on genetic algorithms and dynamic programming. Numerical results based on the modified IEEE 13-node distribution system and a typical 37-node Latin American system validate the effectiveness of the proposed methodology. The obtained results verify that, through the proposed methodology, the DisCo can effectively schedule its installations and DR to minimize the total operational cost while reducing losses and robustly managing voltage and congestion issues.
- Open Access
Reinforcement Learning-Based Pricing and Incentive Strategy for Demand Response in Smart Grids
International agreements support the modernization of electricity networks and renewable energy resources (RES). However, these RES affect market prices due to resource variability (e.g., solar). Among the alternatives, Demand Response (DR) is presented as a tool to improve the balance between electricity supply and demand by adapting consumption to available production. In this sense, this work focuses on developing a DR model that combines price and incentive-based demand response models (P-B and I-B) to efficiently manage consumer demand with data from a real San Juan—Argentina distribution network. In addition, a price scheme is proposed in real time and by the time of use in relation to the consumers’ influence in the peak demand of the system. The proposed schemes increase load factor and improve demand displacement compared to a demand response reference model. In addition, the proposed reinforcement learning model improves short-term and long-term price search. Finally, a description and formulation of the market where the work was implemented is presented.
Open AccessReinforcement Learning-Based Pricing and Incentive Strategy for Demand Response in Smart Grids
International agreements support the modernization of electricity networks and renewable energy resources (RES). However, these RES affect market prices due to resource variability (e.g., solar). Among the alternatives, Demand Response (DR) is presented as a tool to improve the balance between electricity supply and demand by adapting consumption to available production. In this sense, this work focuses on developing a DR model that combines price and incentive-based demand response models (P-B and I-B) to efficiently manage consumer demand with data from a real San Juan—Argentina distribution network. In addition, a price scheme is proposed in real time and by the time of use in relation to the consumers’ influence in the peak demand of the system. The proposed schemes increase load factor and improve demand displacement compared to a demand response reference model. In addition, the proposed reinforcement learning model improves short-term and long-term price search. Finally, a description and formulation of the market where the work was implemented is presented.
- Open Access
- 1 January 2023
- Published by Universidad de Tarapacá in Ingeniare. Revista chilena de ingeniería
- Vol. 31
Oportunidades y desafíos en la planificación de la transmisión zonal de Chile considerando particularidades del sistema de distribución
El desarrollo de nuevas tecnologías y usos de la energía eléctrica, como los recursos energéticos distribuidos, plantean nuevos desafíos y oportunidades de negocio para la industria eléctrica. Ello en pro de realizar un mejor uso de la información para que las empresas puedan gestionar de forma eficiente sus activos (minimizando los costes de inversión y operación, mejorando a su vez la calidad del servicio) y que los usuarios gestionen racionalmente su demanda (haciendo un uso eficiente de los recursos energéticos disponibles). En este sentido, Chile está experimentando un cambio de paradigma en el sector eléctrico, buscando principalmente mejorar la eficiencia energética. En este trabajo se presenta un análisis de las principales problemáticas de los recursos presentes en los Sistemas de Distribución Eléctrica, y se proponen algunas métricas con el fin de que estos sean considerados como insumos (inputs) en los modelos de Planificación de la Transmisión, específicamente en la Transmisión Zonal (o subtransmisión) en Chile.
- 1 January 2023
- Published by Universidad de Tarapacá in Ingeniare. Revista chilena de ingeniería
- Vol. 31
Open AccessOportunidades y desafíos en la planificación de la transmisión zonal de Chile considerando particularidades del sistema de distribución
El desarrollo de nuevas tecnologías y usos de la energía eléctrica, como los recursos energéticos distribuidos, plantean nuevos desafíos y oportunidades de negocio para la industria eléctrica. Ello en pro de realizar un mejor uso de la información para que las empresas puedan gestionar de forma eficiente sus activos (minimizando los costes de inversión y operación, mejorando a su vez la calidad del servicio) y que los usuarios gestionen racionalmente su demanda (haciendo un uso eficiente de los recursos energéticos disponibles). En este sentido, Chile está experimentando un cambio de paradigma en el sector eléctrico, buscando principalmente mejorar la eficiencia energética. En este trabajo se presenta un análisis de las principales problemáticas de los recursos presentes en los Sistemas de Distribución Eléctrica, y se proponen algunas métricas con el fin de que estos sean considerados como insumos (inputs) en los modelos de Planificación de la Transmisión, específicamente en la Transmisión Zonal (o subtransmisión) en Chile.