Suam Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Suam Kim has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed E. Othman
Department of Neuroradiology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
2 shared publications - Antoine Sanner
Department of Neuroradiology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
2 shared publications Elias Kellner
Department of Medical Physics, Universitätsklinikum Freiburg Medizinische Universitätsklinik, Freiburg im Breisgau, Germany
2 shared publicationsElmar Kotter
Department of Diagnostic and Interventional Radiology, Universitätsklinikum Freiburg Medizinische Universitätsklinik, Freiburg im Breisgau, Germany
2 shared publicationsFabian Bamberg
Department of Diagnostic and Interventional Radiology, Universitätsklinikum Freiburg Medizinische Universitätsklinik, Freiburg im Breisgau, Germany
2 shared publicationsMarco Reisert
Department of Medical Physics, Universitätsklinikum Freiburg Medizinische Universitätsklinik, Freiburg im Breisgau, Germany
2 shared publications
Latest Publications
- Open Access
- 22 September 2026
- Published by Springer Nature in Clinical Neuroradiology
- p. 1-12
Deep Learning Reconstruction Enables Substantial Radiation Dose Reduction in Ultra-High-Resolution Temporal Bone CT: a Body Donor Study
Purpose: Deep learning reconstruction may enable substantial radiation dose reduction in ultra–high-resolution (UHR) temporal bone CT, but its performance across clinically relevant dose levels remains insufficiently defined. This study evaluated vendor-specific deep learning reconstruction (DLR) compared with hybrid iterative reconstruction (HIR) in UHR volume-mode temporal bone CT and aimed to propose an indication-adapted framework for dose optimization. Methods: In this single-center body donor study, 20 temporal bones from 10 donors without pathologic findings were scanned at 11 dose levels (CTDI vol , 5.1–30.7 mGy). Images were reconstructed using HIR at standard resolution (0.5 mm, 512 2 matrix) and UHR (0.25 mm, 1024 2 and 2048 2 matrices), as well as DLR (AiCE Inner Ear) at UHR (0.25 mm, 1024 2 matrix). Three radiologists independently assessed 10 anatomical structures using a 5-point Likert scale. Signal-to-noise ratio was measured in predefined regions. Exploratory structure-specific generalized estimating equation models were used to estimate the probability of achieving optimal image quality as a function of radiation dose and reconstruction technique. Results: DLR significantly improved visualization of osseous structures compared with HIR ( p < 0.001). The exploratory dose-response analysis demonstrated reconstruction-specific trajectories, with DLR achieving higher predicted probabilities of optimal image quality than HIR at lower dose levels. For routine clinical indications, diagnostically adequate image quality was achieved with DLR at a CTDI vol of 13.3 mGy, representing a 48% dose reduction compared with HIR (CTDI vol 25.6 mGy). For high-detail assessment of delicate microanatomical structures, including the stapes and cochlea, DLR achieved excellent visualization at a CTDI vol of 17.4 mGy, corresponding to a 43% dose reduction compared with HIR (CTDI vol 30.7 mGy). Conclusion: Vendor-specific DLR enables substantial radiation dose reduction in UHR volume-mode temporal bone CT while maintaining high diagnostic image quality. These findings support an indication-adapted framework for dose optimization, suggesting a routine clinical protocol at CTDI vol 13.3 mGy and a microanatomy-optimized protocol at CTDI vol 17.4 mGy.
- 22 September 2026
- Published by Springer Nature in Clinical Neuroradiology
- p. 1-12
Open AccessDeep Learning Reconstruction Enables Substantial Radiation Dose Reduction in Ultra-High-Resolution Temporal Bone CT: a Body Donor Study
Purpose: Deep learning reconstruction may enable substantial radiation dose reduction in ultra–high-resolution (UHR) temporal bone CT, but its performance across clinically relevant dose levels remains insufficiently defined. This study evaluated vendor-specific deep learning reconstruction (DLR) compared with hybrid iterative reconstruction (HIR) in UHR volume-mode temporal bone CT and aimed to propose an indication-adapted framework for dose optimization. Methods: In this single-center body donor study, 20 temporal bones from 10 donors without pathologic findings were scanned at 11 dose levels (CTDI vol , 5.1–30.7 mGy). Images were reconstructed using HIR at standard resolution (0.5 mm, 512 2 matrix) and UHR (0.25 mm, 1024 2 and 2048 2 matrices), as well as DLR (AiCE Inner Ear) at UHR (0.25 mm, 1024 2 matrix). Three radiologists independently assessed 10 anatomical structures using a 5-point Likert scale. Signal-to-noise ratio was measured in predefined regions. Exploratory structure-specific generalized estimating equation models were used to estimate the probability of achieving optimal image quality as a function of radiation dose and reconstruction technique. Results: DLR significantly improved visualization of osseous structures compared with HIR ( p < 0.001). The exploratory dose-response analysis demonstrated reconstruction-specific trajectories, with DLR achieving higher predicted probabilities of optimal image quality than HIR at lower dose levels. For routine clinical indications, diagnostically adequate image quality was achieved with DLR at a CTDI vol of 13.3 mGy, representing a 48% dose reduction compared with HIR (CTDI vol 25.6 mGy). For high-detail assessment of delicate microanatomical structures, including the stapes and cochlea, DLR achieved excellent visualization at a CTDI vol of 17.4 mGy, corresponding to a 43% dose reduction compared with HIR (CTDI vol 30.7 mGy). Conclusion: Vendor-specific DLR enables substantial radiation dose reduction in UHR volume-mode temporal bone CT while maintaining high diagnostic image quality. These findings support an indication-adapted framework for dose optimization, suggesting a routine clinical protocol at CTDI vol 13.3 mGy and a microanatomy-optimized protocol at CTDI vol 17.4 mGy.
- Open Access
- 24 April 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- p. 1-9
Real-time planar angiographic cerebral perfusion imaging
Purpose: Digital Subtraction Angiography (DSA) is an X-ray-based imaging modality intimately related to minimally invasive procedures in interventional radiology, cardiology, vascular and neurologic surgery. Emulating tomographic methods like 3D vessel reconstruction and flat-panel detector CT perfusion imaging increases its diagnostic utility. This study demonstrates a hardware and software setup expanding DSA capability to functional perfusion imaging by assessing planar cerebral perfusion at runtime. Methods: The setup uses an HDMI video splitter and frame-grabber for duplicating the video output of the intervention suite to an arbitrary machine at the time of image acquisition. A selection of methods, including numerical approximation and neural network inference of fitted curve features, is applied to create perfusion parameter maps and compare their respective completion times over a set of angiographic runs. Results: We identified two distinct perfusion estimation methods able to yield results within 1–2 s, signal deconvolution using single-value decomposition (SVD) and numerical curve feature estimation, as well as a variation on conventional curve fitting that massively shortened calculation times from five minutes to clinically feasible 30 s. Conclusion: Directly accessing image data outside of the angiography suite enables real-time angiographic cerebral perfusion evaluation in the clinical workflow. This way, on-the-fly analysis of angiograms in clinical settings, e.g., angiographic perfusion, is made possible, facilitating future clinical studies.
- 24 April 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- p. 1-9
Open AccessReal-time planar angiographic cerebral perfusion imaging
Purpose: Digital Subtraction Angiography (DSA) is an X-ray-based imaging modality intimately related to minimally invasive procedures in interventional radiology, cardiology, vascular and neurologic surgery. Emulating tomographic methods like 3D vessel reconstruction and flat-panel detector CT perfusion imaging increases its diagnostic utility. This study demonstrates a hardware and software setup expanding DSA capability to functional perfusion imaging by assessing planar cerebral perfusion at runtime. Methods: The setup uses an HDMI video splitter and frame-grabber for duplicating the video output of the intervention suite to an arbitrary machine at the time of image acquisition. A selection of methods, including numerical approximation and neural network inference of fitted curve features, is applied to create perfusion parameter maps and compare their respective completion times over a set of angiographic runs. Results: We identified two distinct perfusion estimation methods able to yield results within 1–2 s, signal deconvolution using single-value decomposition (SVD) and numerical curve feature estimation, as well as a variation on conventional curve fitting that massively shortened calculation times from five minutes to clinically feasible 30 s. Conclusion: Directly accessing image data outside of the angiography suite enables real-time angiographic cerebral perfusion evaluation in the clinical workflow. This way, on-the-fly analysis of angiograms in clinical settings, e.g., angiographic perfusion, is made possible, facilitating future clinical studies.
- Open Access
- 19 March 2026
- Published by SAGE Publications in Journal of Neuromuscular Diseases
- Vol. 13 (6) , 1275-1284
Semi-quantitative analyses of muscle magnetic resonance imaging for pattern recognition in early idiopathic inflammatory myopathies
Background: Idiopathic inflammatory myopathies (IIM) are a group of autoimmune diseases characterized by skeletal muscle inflammation. Magnetic resonance imaging (MRI) is increasingly used in IIM diagnosis, yet standardized protocols and comprehensive datasets remain limited. This study aimed to characterize MRI findings across IIM subtypes, identify muscle involvement patterns, and assess correlations between imaging abnormalities and clinical severity. Methods: In this retrospective cohort study, 34 patients with IIM evaluated between 2012 and 2020 in Düsseldorf and Halle (Germany) were included: Inclusion Body Myositis (IBM, n = 9), Dermatomyositis (DM, n = 5), Polymyositis (PM, n = 6), Anti-Synthetase Syndrome (ASYS, n = 5), and Immune-mediated Necrotizing Myopathy (IMNM, n = 9). Clinical data (autoantibody status, creatine kinase [CK] levels, and muscle strength via Manual-Muscle-Testing-8 [MMT-8]) and muscle MRI findings were analysed. Muscle involvement patterns were characterized, and associations with clinical severity were evaluated using univariate linear regression. Results: MRI abnormalities were evident even in early disease stages (median disease duration: 7 months [IQR: 2–18]). Patterns of muscle involvement differed markedly across IIM subtypes; notably, ASYS and IBM showed minimal involvement of upper extremities. A significant correlation was found between MRI-visible pathology and MMT-8 scores (p = 0.027) as well as CK levels (p = 0.028). Conclusion: MRI reveals subclinical muscle involvement in early IIM and uncovers subtype-specific patterns. Given the heterogeneity of MRI findings, individualized imaging approaches are warranted. While MRI serves as a valuable adjunct in diagnosis and management of IIM, its utility depends on standardized protocols and integration with clinical and laboratory data to enable accurate interpretation and informed decision-making in clinical practice.
- 19 March 2026
- Published by SAGE Publications in Journal of Neuromuscular Diseases
- Vol. 13 (6) , 1275-1284
Open AccessSemi-quantitative analyses of muscle magnetic resonance imaging for pattern recognition in early idiopathic inflammatory myopathies
Background: Idiopathic inflammatory myopathies (IIM) are a group of autoimmune diseases characterized by skeletal muscle inflammation. Magnetic resonance imaging (MRI) is increasingly used in IIM diagnosis, yet standardized protocols and comprehensive datasets remain limited. This study aimed to characterize MRI findings across IIM subtypes, identify muscle involvement patterns, and assess correlations between imaging abnormalities and clinical severity. Methods: In this retrospective cohort study, 34 patients with IIM evaluated between 2012 and 2020 in Düsseldorf and Halle (Germany) were included: Inclusion Body Myositis (IBM, n = 9), Dermatomyositis (DM, n = 5), Polymyositis (PM, n = 6), Anti-Synthetase Syndrome (ASYS, n = 5), and Immune-mediated Necrotizing Myopathy (IMNM, n = 9). Clinical data (autoantibody status, creatine kinase [CK] levels, and muscle strength via Manual-Muscle-Testing-8 [MMT-8]) and muscle MRI findings were analysed. Muscle involvement patterns were characterized, and associations with clinical severity were evaluated using univariate linear regression. Results: MRI abnormalities were evident even in early disease stages (median disease duration: 7 months [IQR: 2–18]). Patterns of muscle involvement differed markedly across IIM subtypes; notably, ASYS and IBM showed minimal involvement of upper extremities. A significant correlation was found between MRI-visible pathology and MMT-8 scores (p = 0.027) as well as CK levels (p = 0.028). Conclusion: MRI reveals subclinical muscle involvement in early IIM and uncovers subtype-specific patterns. Given the heterogeneity of MRI findings, individualized imaging approaches are warranted. While MRI serves as a valuable adjunct in diagnosis and management of IIM, its utility depends on standardized protocols and integration with clinical and laboratory data to enable accurate interpretation and informed decision-making in clinical practice.
- Open Access
AI-based X-ray fracture analysis of the distal radius: accuracy between representative classification, detection and segmentation deep learning models for clinical practice
Objectives To aid in selecting the optimal artificial intelligence (AI) solution for clinical application, we directly compared performances of selected representative custom-trained or commercial classification, detection and segmentation models for fracture detection on musculoskeletal radiographs of the distal radius by aligning their outputs. Design and setting This single-centre retrospective study was conducted on a random subset of emergency department radiographs from 2008 to 2018 of the distal radius in Germany. Materials and methods An image set was created to be compatible with training and testing classification and segmentation models by annotating examinations for fractures and overlaying fracture masks, if applicable. Representative classification and segmentation models were trained on 80% of the data. After output binarisation, their derived fracture detection performances as well as that of a standard commercially available solution were compared on the remaining X-rays (20%) using mainly accuracy and area under the receiver operating characteristic (AUROC). Results A total of 2856 examinations with 712 (24.9%) fractures were included in the analysis. Accuracies reached up to 0.97 for the classification model, 0.94 for the segmentation model and 0.95 for BoneView. Cohen’s kappa was at least 0.80 in pairwise comparisons, while Fleiss’ kappa was 0.83 for all models. Fracture predictions were visualised with all three methods at different levels of detail, ranking from downsampled image region for classification over bounding box for detection to single pixel-level delineation for segmentation. Conclusions All three investigated approaches reached high performances for detection of distal radius fractures with simple preprocessing and postprocessing protocols on the custom-trained models. Despite their underlying structural differences, selection of one’s fracture analysis AI tool in the frame of this study reduces to the desired flavour of automation: automated classification, AI-assisted manual fracture reading or minimised false negatives.
Open AccessAI-based X-ray fracture analysis of the distal radius: accuracy between representative classification, detection and segmentation deep learning models for clinical practice
Objectives To aid in selecting the optimal artificial intelligence (AI) solution for clinical application, we directly compared performances of selected representative custom-trained or commercial classification, detection and segmentation models for fracture detection on musculoskeletal radiographs of the distal radius by aligning their outputs. Design and setting This single-centre retrospective study was conducted on a random subset of emergency department radiographs from 2008 to 2018 of the distal radius in Germany. Materials and methods An image set was created to be compatible with training and testing classification and segmentation models by annotating examinations for fractures and overlaying fracture masks, if applicable. Representative classification and segmentation models were trained on 80% of the data. After output binarisation, their derived fracture detection performances as well as that of a standard commercially available solution were compared on the remaining X-rays (20%) using mainly accuracy and area under the receiver operating characteristic (AUROC). Results A total of 2856 examinations with 712 (24.9%) fractures were included in the analysis. Accuracies reached up to 0.97 for the classification model, 0.94 for the segmentation model and 0.95 for BoneView. Cohen’s kappa was at least 0.80 in pairwise comparisons, while Fleiss’ kappa was 0.83 for all models. Fracture predictions were visualised with all three methods at different levels of detail, ranking from downsampled image region for classification over bounding box for detection to single pixel-level delineation for segmentation. Conclusions All three investigated approaches reached high performances for detection of distal radius fractures with simple preprocessing and postprocessing protocols on the custom-trained models. Despite their underlying structural differences, selection of one’s fracture analysis AI tool in the frame of this study reduces to the desired flavour of automation: automated classification, AI-assisted manual fracture reading or minimised false negatives.
- Open Access
- 2 February 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (5) , 819-826
Multiclass datasets expand neural network utility: an example on ankle radiographs
Purpose: Artificial intelligence in computer vision has been increasingly adapted in clinical application since the implementation of neural networks, potentially providing incremental information beyond the mere detection of pathology. As its algorithmic approach propagates input variation, neural networks could be used to identify and evaluate relevant image features. In this study, we introduce a basic dataset structure and demonstrate a pertaining use case. Methods: A multidimensional classification of ankle x-rays (n = 1493) rating a variety of features including fracture certainty was used to confirm its usability for separating input variations. We trained a customized neural network on the task of fracture detection using a state-of-the-art preprocessing and training protocol. By grouping the radiographs into subsets according to their image features, the influence of selected features on model performance was evaluated via selective training. Results: The models trained on our dataset outperformed most comparable models of current literature with an ROC AUC of 0.943. Excluding ankle x-rays with signs of surgery improved fracture classification performance (AUC 0.955), while limiting the training set to only healthy ankles with and without fracture had no consistent effect. Conclusion: Using multiclass datasets and comparing model performance, we were able to demonstrate signs of surgery as a confounding factor, which, following elimination, improved our model. Also eliminating pathologies other than fracture in contrast had no effect on model performance, suggesting a beneficial influence of feature variability for robust model training. Thus, multiclass datasets allow for evaluation of distinct image features, deepening our understanding of pathology imaging.
- 2 February 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (5) , 819-826
Open AccessMulticlass datasets expand neural network utility: an example on ankle radiographs
Purpose: Artificial intelligence in computer vision has been increasingly adapted in clinical application since the implementation of neural networks, potentially providing incremental information beyond the mere detection of pathology. As its algorithmic approach propagates input variation, neural networks could be used to identify and evaluate relevant image features. In this study, we introduce a basic dataset structure and demonstrate a pertaining use case. Methods: A multidimensional classification of ankle x-rays (n = 1493) rating a variety of features including fracture certainty was used to confirm its usability for separating input variations. We trained a customized neural network on the task of fracture detection using a state-of-the-art preprocessing and training protocol. By grouping the radiographs into subsets according to their image features, the influence of selected features on model performance was evaluated via selective training. Results: The models trained on our dataset outperformed most comparable models of current literature with an ROC AUC of 0.943. Excluding ankle x-rays with signs of surgery improved fracture classification performance (AUC 0.955), while limiting the training set to only healthy ankles with and without fracture had no consistent effect. Conclusion: Using multiclass datasets and comparing model performance, we were able to demonstrate signs of surgery as a confounding factor, which, following elimination, improved our model. Also eliminating pathologies other than fracture in contrast had no effect on model performance, suggesting a beneficial influence of feature variability for robust model training. Thus, multiclass datasets allow for evaluation of distinct image features, deepening our understanding of pathology imaging.
- Open Access
- 26 October 2021
- Published by Springer Nature in BMC Medical Imaging
- Vol. 21 (1) , 1-11
Evaluation of computed tomography settings in the context of visualization and discrimination of low dose injections of a novel liquid soft tissue fiducial marker in head and neck imaging
Intraoperative incorporation of radiopaque fiducial markers at the tumor resection surface can provide useful assistance in identifying the tumor bed in postoperative imaging for RT planning and radiological follow-up. Besides titanium clips, iodine containing injectable liquid fiducial markers represent an option that has emerged more recently for this purpose. In this study, marking oral soft tissue resection surfaces, applying low dose injections of a novel Conformité Européenne (CE)-marked liquid fiducial marker based on sucrose acetoisobutyrate (SAIB) and iodinated SAIB (x-SAIB) was investigated. Visibility and discriminability of low dose injections of SAIB/x-SAIB (10 µl, 20 µl, 30 µl) were systematically studied at different kV settings used in clinical routine in an ex-vivo porcine mandible model. Transferability of the preclinical results into the clinical setting and applicability of DE-CT were investigated in initial patients. Markers created by injection volumes as low as 10 µl were visible in CT imaging at all kV settings applied in clinical routine (70–120 kV). An injection volume of 30 µl allowed differentiation from an injection volume of 10 µl. In a total of 118 injections performed in two head and neck cancer patients, markers were clearly visible in 83% and 86% of injections. DE-CT allowed for differentiation between SAIB/x-SAIB markers and other hyperdense structures. Injection of low doses of SAIB/x-SAIB was found to be a feasible approach to mark oral soft tissue resection surfaces, with injection volumes as low as 10 µl found to be visible at all kV settings applied in clinical routine. With the application of SAIB/x-SAIB reported for tumors of different organs already, mostly applying relatively large volumes for IGRT, this study adds information on the applicability of low dose injections to facilitate identification of the tumor bed in postoperative CT and on performance of the marker at different kV settings used in clinical routine.
- 26 October 2021
- Published by Springer Nature in BMC Medical Imaging
- Vol. 21 (1) , 1-11
Open AccessEvaluation of computed tomography settings in the context of visualization and discrimination of low dose injections of a novel liquid soft tissue fiducial marker in head and neck imaging
Intraoperative incorporation of radiopaque fiducial markers at the tumor resection surface can provide useful assistance in identifying the tumor bed in postoperative imaging for RT planning and radiological follow-up. Besides titanium clips, iodine containing injectable liquid fiducial markers represent an option that has emerged more recently for this purpose. In this study, marking oral soft tissue resection surfaces, applying low dose injections of a novel Conformité Européenne (CE)-marked liquid fiducial marker based on sucrose acetoisobutyrate (SAIB) and iodinated SAIB (x-SAIB) was investigated. Visibility and discriminability of low dose injections of SAIB/x-SAIB (10 µl, 20 µl, 30 µl) were systematically studied at different kV settings used in clinical routine in an ex-vivo porcine mandible model. Transferability of the preclinical results into the clinical setting and applicability of DE-CT were investigated in initial patients. Markers created by injection volumes as low as 10 µl were visible in CT imaging at all kV settings applied in clinical routine (70–120 kV). An injection volume of 30 µl allowed differentiation from an injection volume of 10 µl. In a total of 118 injections performed in two head and neck cancer patients, markers were clearly visible in 83% and 86% of injections. DE-CT allowed for differentiation between SAIB/x-SAIB markers and other hyperdense structures. Injection of low doses of SAIB/x-SAIB was found to be a feasible approach to mark oral soft tissue resection surfaces, with injection volumes as low as 10 µl found to be visible at all kV settings applied in clinical routine. With the application of SAIB/x-SAIB reported for tumors of different organs already, mostly applying relatively large volumes for IGRT, this study adds information on the applicability of low dose injections to facilitate identification of the tumor bed in postoperative CT and on performance of the marker at different kV settings used in clinical routine.