ZLZhiying Li

Zhiying Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhiying Li has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Split Federated Learning for Resource-Constrained Edge Computing Networks

    by Xianghe Wang, Shaoyang Song, Zekai Zhang, Xiangwang Hou, Zhiying Li, Tianyu Xing, Xiao-Ping Zhang

    Compute First Networking (CFN) integrates distributed computing resources across cloud, edge, and device layers to meet diverse computing demands. Within this context, Split Federated Learning (SFL) has emerged as an effective approach to reduce device workload and enhance privacy by integrating model splitting into federated training. However, deploying SFL in edge computing networks is challenging due to device heterogeneity, unreliable channels, and the trade-off between convergence and resource usage. This paper formulates a joint optimization problem that considers split layer selection, computing resource allocation, and transmission power control to minimize the total training latency required to reach a target model accuracy. We propose an efficient Block Coordinate Descent (BCD)-based algorithm to solve this problem. Experimental results demonstrate that the proposed framework significantly reduces the total training latency and adapts effectively to varying wireless conditions.


  • A Defects Detection Method of Buried Liquid-Filled Pipes Based on T(0,1) Guided Waves

    by Fulu Liu, Zhiying Li, Xiaofei Huang, Linhui Ma, Jiyao Li, Hang Pu, Jun Long, Lijun Xu, Yuedong Xie

    In this paper, we propose a method using T(0,1) guided waves combined with coil coding technique to detect defects in buried liquid-filled pipes implemented by an electromagnetic acoustic transducer (EMAT). Due to its non-dispersive properties and the fact that there is no energy loss in non-viscoelastic fluids, the T(0,1) mode is selected for pipe defects detection. The electromagnetic device that generates the circumferential magnetic field is optimized to excite the pure T(0,1) mode. To realize energy enhancement and defect location identification, the electromagnetic acoustic coil is spatially encoded by 11-bit Barker code and the receiver coil is multiplexed consisting of a spatial coded coil and a unit coil. The defect detection is accomplished through time-of-flight (TOF) time-frequency analysis, and the defect location identification is achieved by digital signal processing methods (cross-correlation and convolution). The feasibility of this method is verified by the finite element model and experimental analysis, indicating the defect locating error in a liquid-filled pipes is less than 1%. Overall, the proposed method achieves a high-precision flaw detection and location identification.


  • A Novel Noncontact Method for Phase Interface Measurement in Liquid-Filled Pipe Using Leaky L(0,2) Wave

    by Fulu Liu, Jiyao Li, Zhiying Li, Jun Long, Lijun Xu, Yuedong Xie

    In this paper, we propose a novel phase interface measurement method in the liquid-filled pipe using leaky L(0,2) wave implemented by an electromagnetic acoustic transducer (EMAT). Two EMATs with flexible coils are circumferentially wrapped on the liquid-filled pipe, acting as exciting EMAT and receiving EMAT respectively. The coil used in the excitation EMAT is a ten-turn meander-line-coil exited with a five-cycle Hanning windowed tone burst signal to produce pure leaky L(0,2) waves. The feasibility of this method has been verified by finite element model and experimental analysis. During experiments, the liquid levels in the vertical pipe and horizontal pipe can be obtained by means of the amplitude of the received L(0,2) wave. Various diameters of the rod were used to model different phase interfaces and the results indicate the diameter is linear to the arrival time of the leaking L(0,2) wave. Meanwhile, the amplitude of the leaky L(0,2) signal in a certain range is used to express the reflectivity of the phase interface. Based on these results, the proposed method can be used for phase interface measurement, and provides a potential of phase interface imaging.


  • Measurement of Lift-Off Distance and Thickness of Nonmagnetic Metallic Plate Using Pulsed Eddy Current Testing

    by Pu Huang, Zhiying Li, Jun Long, Lijun Xu, Yuedong Xie

    Eddy current testing (ECT) is an efficient method to estimate the thickness of sample but it is affected by other parameters information including electromagnetic properties and lift-off. In the previous researches, the lift-off point of intersection (LOI) feature has been found in pulsed eddy current (PEC), which can overcome the fluctuation of lift-off. In this paper, another feature, i.e. conductivity point of intersection(CPI), is proposed for non-coaxial T-R sensor in PEC. Specifically, the response signals of different sample conductivity almost intersect with each other at the certain time, which can be regarded immune to the conductivity of sample. The analytical solution and numerical solution are conducted, and the results indicate that the intersection point magnitude is mainly related with parameters of sensor and thickness of samples. Considering the elements related with conductivity in the Hessian matrix exists ill-conditioning, it will produce the magnification of measurement error under iterative inversion process. By referring to the CPI feature, the thickness of the sample and lift-off of sensor can be accurately inverted based on the modified Newton–Raphson method. The experiments are carried out to verify the proposed method, and the error is only 2.9%.


  • Decoupling Conductivity and Permeability Using Sweep-Frequency Eddy Current Method

    by Pu Huang, Jingyu Zhao, Zhiying Li, Hang Pu, Yiqing Ding, Lijun Xu, Yuedong Xie

    Electromagnetic coupling and lift-off variation are obstacles in the eddy current method. In this paper, we proposed a sweep frequency eddy current method to achieve conductivity and permeability simultaneous measurements immune to lift-off. The relationship between eddy current detection signals of different frequencies and electromagnetic parameters of magnetic materials has been found. That is, the real part of mutual inductance is mainly related to permeability at low frequency. In high frequency, the zero crossover-frequency is the proportional to the ratio of permeability and conductivity. By combining the analysis mentioned above, conductivity and permeability can be estimated simultaneously. In order to eliminate the interference of lift-off, a sensor structure with one excitation coil and two receiving coils is designed to compensate the mutual inductance changes caused by lift-off. Experiments and FEM simulations are also carried out to verify the proposed method. The results show the errors of conductivity and permeability are 1.3% and 3.9% respectively, and the error caused by reasonable variation range of lift-off can be significantly reduced.