Tommaso Fiumalbi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tommaso Fiumalbi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Baldoni
The BioRobotics Institute, Scuola Superiore SantAnna, Pontedera, Italy
2 shared publications - Emilio Trigili
BioRobotics Institute, Scuola Superiore Sant’Anna, Pontedera, Italy
2 shared publications - Filippo Dell’agnello
The BioRobotics Institute, Scuola Superiore SantAnna, Pontedera, Italy
2 shared publications - Nicola Vitiello
BioRobotics Institute, Scuola Superiore Sant’Anna, Pontedera, Italy
2 shared publications - Simona Crea
BioRobotics Institute, Scuola Superiore SantAnna, Pontedera, Italy
2 shared publications Alessandro Maselli
Institute of Recovery and Care of Scientific Character (IRCCS), Fondazione Don Carlo Gnocchi, Firenze, Italy
1 shared publication
Latest Publications
- Open Access
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 3306-3321
An Underactuated Active Transfemoral Prosthesis With Series Elastic Actuators Enables Multiple Locomotion Tasks
Robotic lower-limb prostheses have the power to revolutionize mobility by enhancing gait efficiency and facilitating movement. While several design approaches have been explored to create lightweight and energy-efficient devices, the potential of underactuation remains largely untapped in lower-limb prosthetics. Taking inspiration from the natural harmony of walking, we have developed an innovative active transfemoral prosthesis. By incorporating underactuation, our design uses a single power actuator placed near the knee joint and connected to a differential mechanism to drive both the knee and ankle joints. We conducted comprehensive benchtop tests and evaluated the prosthesis with three individuals who have above-knee amputations, assessing its performance in walking, stair climbing, and transitions between sitting and standing. Our evaluation focused on gathering position and torque data recorded from sensors integrated into the prosthesis and comparing these measurements to biomechanical data of able-bodied locomotion. Our findings highlight the promise of underactuation in advancing lower-limb prosthetics and demonstrate the feasibility of our kneeankle underactuated design in various tasks, showcasing its ability to replicate natural movement
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 3306-3321
Open AccessAn Underactuated Active Transfemoral Prosthesis With Series Elastic Actuators Enables Multiple Locomotion Tasks
Robotic lower-limb prostheses have the power to revolutionize mobility by enhancing gait efficiency and facilitating movement. While several design approaches have been explored to create lightweight and energy-efficient devices, the potential of underactuation remains largely untapped in lower-limb prosthetics. Taking inspiration from the natural harmony of walking, we have developed an innovative active transfemoral prosthesis. By incorporating underactuation, our design uses a single power actuator placed near the knee joint and connected to a differential mechanism to drive both the knee and ankle joints. We conducted comprehensive benchtop tests and evaluated the prosthesis with three individuals who have above-knee amputations, assessing its performance in walking, stair climbing, and transitions between sitting and standing. Our evaluation focused on gathering position and torque data recorded from sensors integrated into the prosthesis and comparing these measurements to biomechanical data of able-bodied locomotion. Our findings highlight the promise of underactuation in advancing lower-limb prosthetics and demonstrate the feasibility of our kneeankle underactuated design in various tasks, showcasing its ability to replicate natural movement
- Open Access
- 11 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 884-894
Self-Aligning Finger Exoskeleton for the Mobilization of the Metacarpophalangeal Joint
In the context of hand and finger rehabilitation, kinematic compatibility is key for the acceptability and clinical exploitation of robotic devices. Different kinematic chain solutions have been proposed in the state of the art, with different trade-offs between characteristics of kinematic compatibility, adaptability to different anthropometries, and the ability to compute relevant clinical information. This study presents the design of a novel kinematic chain for the mobilization of the metacarpophalangeal (MCP) joint of the long fingers and a mathematical model for the real-time computation of the joint angle and transferred torque. The proposed mechanism can self-align with the human joint without hindering force transfer or inducing parasitic torque. The chain has been designed for integration into an exoskeletal device aimed at rehabilitating traumatic-hand patients. The exoskeleton actuation unit has a series-elastic architecture for compliant human-robot interaction and has been assembled and preliminarily tested in experiments with eight human subjects. Performance has been investigated in terms of (i) accuracy of the MCP joint angle estimation through comparison with a video-based motion tracking system, (ii) residual MCP torque when the exoskeleton is controlled to provide null output impedance and (iii) torque-tracking performance. Results showed a root-mean-square error (RMSE) below 5 degrees in the estimated MCP angle. The estimated residual MCP torque resulted below 7 mNm. Torque tracking performance shows an RMSE lower than 8 mNm in following sinusoidal reference profiles. The results encourage further investigations of the device in a clinical scenario.
- 11 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 884-894
Open AccessSelf-Aligning Finger Exoskeleton for the Mobilization of the Metacarpophalangeal Joint
In the context of hand and finger rehabilitation, kinematic compatibility is key for the acceptability and clinical exploitation of robotic devices. Different kinematic chain solutions have been proposed in the state of the art, with different trade-offs between characteristics of kinematic compatibility, adaptability to different anthropometries, and the ability to compute relevant clinical information. This study presents the design of a novel kinematic chain for the mobilization of the metacarpophalangeal (MCP) joint of the long fingers and a mathematical model for the real-time computation of the joint angle and transferred torque. The proposed mechanism can self-align with the human joint without hindering force transfer or inducing parasitic torque. The chain has been designed for integration into an exoskeletal device aimed at rehabilitating traumatic-hand patients. The exoskeleton actuation unit has a series-elastic architecture for compliant human-robot interaction and has been assembled and preliminarily tested in experiments with eight human subjects. Performance has been investigated in terms of (i) accuracy of the MCP joint angle estimation through comparison with a video-based motion tracking system, (ii) residual MCP torque when the exoskeleton is controlled to provide null output impedance and (iii) torque-tracking performance. Results showed a root-mean-square error (RMSE) below 5 degrees in the estimated MCP angle. The estimated residual MCP torque resulted below 7 mNm. Torque tracking performance shows an RMSE lower than 8 mNm in following sinusoidal reference profiles. The results encourage further investigations of the device in a clinical scenario.