Mirna Fouad Abd El-Salam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mirna Fouad Abd El-Salam has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Eman Beshr
Electrical and Control Engineering Department, Arab Academy for Science, Technology and Maritime Transport, Cairo 11311, Egypt
2 shared publicationsAlmoataz Y. Abdelaziz
Faculty of Engineering & Technology, Future University in Egypt, Cairo 11835, Egypt
1 shared publication- Eman Beshr
Electrical and Control Engineering Department, Arab Academy for Science, Technology, and Maritime Transport, Sheraton Al Matar, P.O.2033 Elhorria, Cairo 11311, Egypt
1 shared publication Magdy B. Eteiba
Department of Electrical Power Engineering, Fayoum University, Cairo, Egypt
1 shared publication- Magdy. B. Eteiba
Electrical Engineering Department, Faculty of Engineering, Fayoum University, Fayoum 63514, Egypt
1 shared publication Mohamed Ezzat
Electrical Power and Machines Department, Faculty of Engineering, Ain Shams University, Cairo 11517, Egypt
1 shared publication
Latest Publications
- Open Access
- 30 January 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 38 (2) , 196-213
Hybrid Siting and Sizing of Distributed Generators and Shunt Capacitors with System Reconfiguration using Wild Horse Optimizer
Injection of Distributed generators (DGS) and Shunt capacitors (SCS) simultaneously with system reconfiguration significantly promotes smart grid performance. In addition, system reconfiguration increases the injected distributed generation capacity in the system. This work proposes a wild horse optimizer (WHO) for the optimal siting and sizing of DGS and SCS in parallel with network reconfiguration. The proposed method aims to attain single and multi-objectives: minimizing active power loss, maximizing voltage stability index (VSI), and minimizing voltage deviation index (VDI). Five operational cases are introduced to elucidate the superior performance of the proposed method. The five cases are executed on IEEE 33-bus standard radial distribution test system. The single-objective function results are compared with other optimization algorithms. The simulation results belay that the proposed WHO optimizer has the best results for unfixed DGS and SCS locations.
- 30 January 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 38 (2) , 196-213
Open AccessHybrid Siting and Sizing of Distributed Generators and Shunt Capacitors with System Reconfiguration using Wild Horse Optimizer
Injection of Distributed generators (DGS) and Shunt capacitors (SCS) simultaneously with system reconfiguration significantly promotes smart grid performance. In addition, system reconfiguration increases the injected distributed generation capacity in the system. This work proposes a wild horse optimizer (WHO) for the optimal siting and sizing of DGS and SCS in parallel with network reconfiguration. The proposed method aims to attain single and multi-objectives: minimizing active power loss, maximizing voltage stability index (VSI), and minimizing voltage deviation index (VDI). Five operational cases are introduced to elucidate the superior performance of the proposed method. The five cases are executed on IEEE 33-bus standard radial distribution test system. The single-objective function results are compared with other optimization algorithms. The simulation results belay that the proposed WHO optimizer has the best results for unfixed DGS and SCS locations.
- Open Access
A New Hybrid Technique for Minimizing Power Losses in a Distribution System by Optimal Sizing and Siting of Distributed Generators with Network Reconfiguration
Transformations are taking place within the distribution systems to cope with the congestions and reliability concerns. This paper presents a new technique to efficiently minimize power losses within the distribution system by optimally sizing and placing distributed generators (DGs) while considering network reconfiguration. The proposed technique is a hybridization of two metaheuristic-based algorithms: Grey Wolf Optimizer (GWO) and Particle Swarm Optimizer (PSO), which solve the network reconfiguration problem by optimally installing different DG types (conventional and renewable-based). Case studies carried out showed the proposed hybrid technique outperformed each algorithm operating individually regarding both voltage profile and reduction in system losses. Case studies are carried to measure and compare the performance of the proposed technique on three different works: IEEE 33-bus, IEEE 69-bus radial distribution system, and an actual 78-bus distribution system located at Cairo, Egypt. The integration of renewable energy with the distribution network, such as photovoltaic (PV) arrays, is recommended since Cairo enjoys an excellent actual record of irradiance according to the PV map of Egypt.
Open AccessA New Hybrid Technique for Minimizing Power Losses in a Distribution System by Optimal Sizing and Siting of Distributed Generators with Network Reconfiguration
Transformations are taking place within the distribution systems to cope with the congestions and reliability concerns. This paper presents a new technique to efficiently minimize power losses within the distribution system by optimally sizing and placing distributed generators (DGs) while considering network reconfiguration. The proposed technique is a hybridization of two metaheuristic-based algorithms: Grey Wolf Optimizer (GWO) and Particle Swarm Optimizer (PSO), which solve the network reconfiguration problem by optimally installing different DG types (conventional and renewable-based). Case studies carried out showed the proposed hybrid technique outperformed each algorithm operating individually regarding both voltage profile and reduction in system losses. Case studies are carried to measure and compare the performance of the proposed technique on three different works: IEEE 33-bus, IEEE 69-bus radial distribution system, and an actual 78-bus distribution system located at Cairo, Egypt. The integration of renewable energy with the distribution network, such as photovoltaic (PV) arrays, is recommended since Cairo enjoys an excellent actual record of irradiance according to the PV map of Egypt.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Minimizing Power Loss in Distribution System by Optimal Sizing and Sitting of Distributed Generators with Network Reconfiguration Using Grey Wolf and Particle Swarm Optimizers
This paper presents two meta-heuristic based algorithms, Grey Wolf Optimizer (GWO) and Particle Swarm Optimizer (PSO), to solve network reconfiguration problem in the presence of installing multiple renewable Distributed Generators (DGs). These algorithms are applied to IEEE 33-bus to minimize the real power loss. The results clearly indicate that there is a considerable reduction in the real power loss, reactive power loss, and improvement of the voltage profile.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Minimizing Power Loss in Distribution System by Optimal Sizing and Sitting of Distributed Generators with Network Reconfiguration Using Grey Wolf and Particle Swarm Optimizers
This paper presents two meta-heuristic based algorithms, Grey Wolf Optimizer (GWO) and Particle Swarm Optimizer (PSO), to solve network reconfiguration problem in the presence of installing multiple renewable Distributed Generators (DGs). These algorithms are applied to IEEE 33-bus to minimize the real power loss. The results clearly indicate that there is a considerable reduction in the real power loss, reactive power loss, and improvement of the voltage profile.