Hugo Bouchard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hugo Bouchard has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Arthur Lalonde
Université de Montréal de l’Université de Montréal
3 shared publications François Therriault-Proulx
Medscint.inc, 9 rue McMahon, Québec, Quebec, G1R 3S3, CANADA
2 shared publications- Ilias Billas
National Physical Laboratory, Hampton Rd, Teddington, Teddington , TW11 0LW, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
2 shared publications - Louis Archambault
Université Laval
2 shared publications - Luc Beaulieu
Physique, génie physique et optique, Universite Laval, 2375 rue de la Terrasse, 1401 18e rue, Quebec, G1J 1Z4, CANADA
2 shared publications Simon Lambert-Girard
Medscint.inc, 9 rue McMahon, Québec, Quebec, G1R 3S3, CANADA
2 shared publications
Latest Publications
- Open Access
- 7 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (10) , 105005
A systematic characterization of plastic scintillation dosimeters response in magnetic fields: I. Experimental measurements
Objective. This study aims to evaluate the performance of five distinct plastic scintillation dosimeters (PSDs) in magnetic fields, as well as to validate the accuracy of the hyperspectral approach for stem-effect correction. The effect of the magnetic field on different base core materials and components within the PSDs was also investigated, as well as the effect of field size and orientation. Approach. Each PSD was placed at 5 cm depth in a water tank inside an electromagnet gap. Magnetic fields, between 0 and 1.5 T, were set to be perpendicular to the 6 MeV photon beam and to the PSD axis. The detector axis was either parallel or perpendicular to the photon beam. Different field sizes were used. The hyperspectral technique was validated and used to determine the scintillation, fluorescence and Cherenkov components at different magnetic fields. Main results. The hyperspectral method accurately removes stem effects in magnetic fields, even when calibration is performed at 0 T. The stem light yield shows good agreement with clear fiber measurements, with relative differences within 2.0%. In the parallel orientation, the corrected PSD response is highly symmetric relative to magnetic field polarity, with a maximum variation of only 0.2% from unity. Scintillation light yield increases with magnetic field by 3.6%–6.25% depending on PSD properties. Cherenkov light yield varies up to 230% and down to 0.30% of the 0 T value, depending on magnetic field polarity. The impact of magnetic fields depends primarily on the properties of the scintillator itself, with polyvinyltoluene-based probes showing greater sensitivity than polystyrene-based probes. The inclusion of a wavelength shifter has minimal on the magnetic field’s effect on scintillation light yield. Normalized scintillation light yield decreases with smaller field sizes. Significance. PSDs are well-suited for accurate dosimetry in magnetic fields, provided that accurate stem-effect correction techniques are applied. The scintillator properties play a significant role in determining the PSD’s sensitivity to magnetic fields. The hyperspectral method is a robust approach for accurate stem-effect removal in such conditions.
- 7 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (10) , 105005
Open AccessA systematic characterization of plastic scintillation dosimeters response in magnetic fields: I. Experimental measurements
Objective. This study aims to evaluate the performance of five distinct plastic scintillation dosimeters (PSDs) in magnetic fields, as well as to validate the accuracy of the hyperspectral approach for stem-effect correction. The effect of the magnetic field on different base core materials and components within the PSDs was also investigated, as well as the effect of field size and orientation. Approach. Each PSD was placed at 5 cm depth in a water tank inside an electromagnet gap. Magnetic fields, between 0 and 1.5 T, were set to be perpendicular to the 6 MeV photon beam and to the PSD axis. The detector axis was either parallel or perpendicular to the photon beam. Different field sizes were used. The hyperspectral technique was validated and used to determine the scintillation, fluorescence and Cherenkov components at different magnetic fields. Main results. The hyperspectral method accurately removes stem effects in magnetic fields, even when calibration is performed at 0 T. The stem light yield shows good agreement with clear fiber measurements, with relative differences within 2.0%. In the parallel orientation, the corrected PSD response is highly symmetric relative to magnetic field polarity, with a maximum variation of only 0.2% from unity. Scintillation light yield increases with magnetic field by 3.6%–6.25% depending on PSD properties. Cherenkov light yield varies up to 230% and down to 0.30% of the 0 T value, depending on magnetic field polarity. The impact of magnetic fields depends primarily on the properties of the scintillator itself, with polyvinyltoluene-based probes showing greater sensitivity than polystyrene-based probes. The inclusion of a wavelength shifter has minimal on the magnetic field’s effect on scintillation light yield. Normalized scintillation light yield decreases with smaller field sizes. Significance. PSDs are well-suited for accurate dosimetry in magnetic fields, provided that accurate stem-effect correction techniques are applied. The scintillator properties play a significant role in determining the PSD’s sensitivity to magnetic fields. The hyperspectral method is a robust approach for accurate stem-effect removal in such conditions.
- Open Access
- 7 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (10) , 105004
A systematic characterization of plastic scintillation dosimeters response in magnetic fields: II. Monte Carlo simulations
Purpose. This study aims to investigate and validate the response of plastic scintillation dosimeters (PSDs) in the presence of magnetic fields using Monte Carlo simulations, focusing on the accuracy of electron fluence, dose calculations, and the optical processes of scintillation and Cherenkov radiation. Methods. Monte Carlo simulations, using EGSnrc and TOPAS, of the PSD response under magnetic fields were performed. First, electron fluence simulations were conducted with three different physics lists g4em-penelope, g4em-standard_opt3 and g4em-standard_opt4, with the goal of benchmarking their performance in magnetic fields. Secondly, a Fano test for dose calculations was performed using only the g4em-penelope physics list. Thirdly, the Cherenkov process under magnetic fields was validated against theoretical predictions. Finally, a PSD probe was modeled and simulated, with results compared against measurements. Results. The g4em-penelope physics list demonstrated a most balanced performance, showing the closest agreement with EGSnrc simulations and lower variability in magnetic fields than g4em-standard_opt4. Fano test results showed an accuracy of at least 0.36% for dose calculations. Simulations of Cherenkov radiation in ideal conditions were in agreement with theoretical predictions at both 0 T and 1.5 T. Monte Carlo simulations successfully reproduced experimental trends for Cherenkov radiation under magnetic fields. However, discrepancies were found, with deviations of up to 7.7% when electrons were deflected towards the tip and up to 21.0% in the opposite direction, likely due to modeling limitations. A key result is that Monte Carlo simulations of the scintillation process in magnetic fields failed to reproduce experimental observations. While experimental results showed a significant effect of magnetic fields on scintillation yield, the simulations did not reflect this behavior. Conclusion. This study establishes that TOPAS, specifically using the g4em-penelope physics list, is a reliable tool for simulating dose, electron fluence, and Cherenkov radiation in the presence of magnetic fields. However, significant discrepancies were observed in the scintillation processes, where Monte Carlo simulations failed to reproduce the effect of magnetic fields seen in experimental measurements. These findings point out the need for further refinement of simulation models, particularly in accurately representing scintillation under magnetic fields.
- 7 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (10) , 105004
Open AccessA systematic characterization of plastic scintillation dosimeters response in magnetic fields: II. Monte Carlo simulations
Purpose. This study aims to investigate and validate the response of plastic scintillation dosimeters (PSDs) in the presence of magnetic fields using Monte Carlo simulations, focusing on the accuracy of electron fluence, dose calculations, and the optical processes of scintillation and Cherenkov radiation. Methods. Monte Carlo simulations, using EGSnrc and TOPAS, of the PSD response under magnetic fields were performed. First, electron fluence simulations were conducted with three different physics lists g4em-penelope, g4em-standard_opt3 and g4em-standard_opt4, with the goal of benchmarking their performance in magnetic fields. Secondly, a Fano test for dose calculations was performed using only the g4em-penelope physics list. Thirdly, the Cherenkov process under magnetic fields was validated against theoretical predictions. Finally, a PSD probe was modeled and simulated, with results compared against measurements. Results. The g4em-penelope physics list demonstrated a most balanced performance, showing the closest agreement with EGSnrc simulations and lower variability in magnetic fields than g4em-standard_opt4. Fano test results showed an accuracy of at least 0.36% for dose calculations. Simulations of Cherenkov radiation in ideal conditions were in agreement with theoretical predictions at both 0 T and 1.5 T. Monte Carlo simulations successfully reproduced experimental trends for Cherenkov radiation under magnetic fields. However, discrepancies were found, with deviations of up to 7.7% when electrons were deflected towards the tip and up to 21.0% in the opposite direction, likely due to modeling limitations. A key result is that Monte Carlo simulations of the scintillation process in magnetic fields failed to reproduce experimental observations. While experimental results showed a significant effect of magnetic fields on scintillation yield, the simulations did not reflect this behavior. Conclusion. This study establishes that TOPAS, specifically using the g4em-penelope physics list, is a reliable tool for simulating dose, electron fluence, and Cherenkov radiation in the presence of magnetic fields. However, significant discrepancies were observed in the scintillation processes, where Monte Carlo simulations failed to reproduce the effect of magnetic fields seen in experimental measurements. These findings point out the need for further refinement of simulation models, particularly in accurately representing scintillation under magnetic fields.
- Open Access
- 4 April 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (8) , 085002
Physics-based energy spectrum optimization (PESO): a new method to model the energy spectrum of a compact ultra-high dose rate electron linac for Monte Carlo dose calculation
Objective. FLASH radiotherapy (FLASH-RT) is an emerging treatment modality that delivers ultra-high dose rates (UHDR) to achieve effective tumor control while minimizing damage to healthy tissues—a phenomenon known as the FLASH effect. Accurate modeling of the electron energy spectrum is essential for UHDR linacs used in FLASH-RT to ensure reliable dose calculations and effective treatment planning. This study introduces a novel, physics-based method to reconstruct electron energy spectra specifically tailored for compact UHDR linacs lacking bending magnets, which present unique challenges for beam modeling. Approach. A physics-based energy spectrum optimization (PESO) algorithm was developed to model electron beam dynamics within a compact linac with minimal free parameters. The PESO approach was evaluated against two conventional methods—simulated annealing (SA) and Gaussian regression (GR)—using radiochromic film measurements in solid water phantoms for three applicator sizes (25 mm, 40 mm, and 60 mm) in both conventional and FLASH modes. Accuracy of the reconstructed isodoses and robustness against measurement errors was evaluated for each method. Main results. We successfully implemented the PESO algorithm to resolve the electron beam dynamics as a function of the electric field within the waveguide. The method constrained the solution to physically plausible spectra and achieved superior dosimetric accuracy compared to both GR and SA for the 6 MeV UHDR beam, while producing results comparable to SA (and better than GR) for the 9 MeV UHDR beam. PESO also demonstrated reduced sensitivity to measurement errors and maintained consistency, even for the low-energy tail components of UHDR electron beams. Significance. By incorporating physically based constraints into the beam modeling process, PESO offers improvements in the reliability and precision of electron energy spectrum reconstruction for UHDR linacs. This development addresses challenges in electron FLASH-RT dose calculation and may aid in the clinical implementation of FLASH radiotherapy.
- 4 April 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (8) , 085002
Open AccessPhysics-based energy spectrum optimization (PESO): a new method to model the energy spectrum of a compact ultra-high dose rate electron linac for Monte Carlo dose calculation
Objective. FLASH radiotherapy (FLASH-RT) is an emerging treatment modality that delivers ultra-high dose rates (UHDR) to achieve effective tumor control while minimizing damage to healthy tissues—a phenomenon known as the FLASH effect. Accurate modeling of the electron energy spectrum is essential for UHDR linacs used in FLASH-RT to ensure reliable dose calculations and effective treatment planning. This study introduces a novel, physics-based method to reconstruct electron energy spectra specifically tailored for compact UHDR linacs lacking bending magnets, which present unique challenges for beam modeling. Approach. A physics-based energy spectrum optimization (PESO) algorithm was developed to model electron beam dynamics within a compact linac with minimal free parameters. The PESO approach was evaluated against two conventional methods—simulated annealing (SA) and Gaussian regression (GR)—using radiochromic film measurements in solid water phantoms for three applicator sizes (25 mm, 40 mm, and 60 mm) in both conventional and FLASH modes. Accuracy of the reconstructed isodoses and robustness against measurement errors was evaluated for each method. Main results. We successfully implemented the PESO algorithm to resolve the electron beam dynamics as a function of the electric field within the waveguide. The method constrained the solution to physically plausible spectra and achieved superior dosimetric accuracy compared to both GR and SA for the 6 MeV UHDR beam, while producing results comparable to SA (and better than GR) for the 9 MeV UHDR beam. PESO also demonstrated reduced sensitivity to measurement errors and maintained consistency, even for the low-energy tail components of UHDR electron beams. Significance. By incorporating physically based constraints into the beam modeling process, PESO offers improvements in the reliability and precision of electron energy spectrum reconstruction for UHDR linacs. This development addresses challenges in electron FLASH-RT dose calculation and may aid in the clinical implementation of FLASH radiotherapy.
- Open Access
- 9 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (24) , 245008
Dual virtual non-contrast imaging: a Bayesian quantitative approach to determine radiotherapy quantities from contrast-enhanced DECT images
Objective. Contrast agents in computed tomography (CT) scans can compromise the accuracy of dose calculations in radiation therapy planning, especially for particle therapy. This often requires an additional non-contrast CT scan, increasing radiation exposure and introducing potential registration errors. Our goal is to resolve these issues by accurately estimating radiotherapy parameters from dual virtual non-contrast (dual-VNC) images generated by contrast-enhanced dual-energy CT (DECT) scans, while accounting for noise and variability in tissue composition. Approach. A new Bayesian model is introduced to estimate dual-VNC Hounsfield units from contrast-enhanced DECT data. The model defines a prior distribution that describes tissue variations in terms of elemental compositions and mass densities. Multiple reference tissues are used to estimate variations across human tissues. A likelihood distribution is also defined to model the noise contained in CT data. The model is thoroughly validated in a simulated environment including 12 virtual patients under low and high iodine uptake scenarios, while incorporating noise and beam hardening effects. The eigentissue decomposition technique is used to derive elemental compositions and parameters critical for radiotherapy from the dual-VNC images, such as electron density ( ρ e ), particle stopping power (SPR), and photon energy absorption coefficient (EAC). Main results. The proposed method yields accurate voxelwise estimations for ρ e , SPR, and EAC, with root mean square errors of 3.09%, 3.14%, and 1.34% for highly-enhanced tissues, compared to 5.93%, 6.39%, and 17.11% when the presence of contrast agent is ignored. It also demonstrates robustness to systematic shifts in tissue composition and bandwidth variations in the prior distribution, resulting in overall uncertainties down to 1.13%, 1.33%, and 0.86% for ρ e , SPR, and EAC in soft tissues; 1.17%, 1.32%, and 1.34% in enhanced soft tissues; and 4.34%, 4.00%, and 2.50% in bones. Significance. The proposed method accurately derives radiotherapy parameters from contrast-enhanced DECT data and demonstrates robustness against systematic errors in reference data, highlighting its potential for clinical use.
- 9 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (24) , 245008
Open AccessDual virtual non-contrast imaging: a Bayesian quantitative approach to determine radiotherapy quantities from contrast-enhanced DECT images
Objective. Contrast agents in computed tomography (CT) scans can compromise the accuracy of dose calculations in radiation therapy planning, especially for particle therapy. This often requires an additional non-contrast CT scan, increasing radiation exposure and introducing potential registration errors. Our goal is to resolve these issues by accurately estimating radiotherapy parameters from dual virtual non-contrast (dual-VNC) images generated by contrast-enhanced dual-energy CT (DECT) scans, while accounting for noise and variability in tissue composition. Approach. A new Bayesian model is introduced to estimate dual-VNC Hounsfield units from contrast-enhanced DECT data. The model defines a prior distribution that describes tissue variations in terms of elemental compositions and mass densities. Multiple reference tissues are used to estimate variations across human tissues. A likelihood distribution is also defined to model the noise contained in CT data. The model is thoroughly validated in a simulated environment including 12 virtual patients under low and high iodine uptake scenarios, while incorporating noise and beam hardening effects. The eigentissue decomposition technique is used to derive elemental compositions and parameters critical for radiotherapy from the dual-VNC images, such as electron density ( ρ e ), particle stopping power (SPR), and photon energy absorption coefficient (EAC). Main results. The proposed method yields accurate voxelwise estimations for ρ e , SPR, and EAC, with root mean square errors of 3.09%, 3.14%, and 1.34% for highly-enhanced tissues, compared to 5.93%, 6.39%, and 17.11% when the presence of contrast agent is ignored. It also demonstrates robustness to systematic shifts in tissue composition and bandwidth variations in the prior distribution, resulting in overall uncertainties down to 1.13%, 1.33%, and 0.86% for ρ e , SPR, and EAC in soft tissues; 1.17%, 1.32%, and 1.34% in enhanced soft tissues; and 4.34%, 4.00%, and 2.50% in bones. Significance. The proposed method accurately derives radiotherapy parameters from contrast-enhanced DECT data and demonstrates robustness against systematic errors in reference data, highlighting its potential for clinical use.
- Open Access
- 6 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (4) , 04TR01
Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential
Range uncertainty has been a key factor preventing particle radiotherapy from reaching its full physical potential. One of the main contributing sources is the uncertainty in estimating particle stopping power (ρ s ) within patients. Currently, the ρ s distribution in a patient is derived from a single-energy CT (SECT) scan acquired for treatment planning by converting CT number expressed in Hounsfield units (HU) of each voxel to ρ s using a Hounsfield look-up table (HLUT), also known as the CT calibration curve. HU and ρ s share a linear relationship with electron density but differ in their additional dependence on elemental composition through different physical properties, i.e. effective atomic number and mean excitation energy, respectively. Because of that, the HLUT approach is particularly sensitive to differences in elemental composition between real human tissues and tissue surrogates as well as tissue variations within and among individual patients. The use of dual-energy CT (DECT) for ρ s prediction has been shown to be effective in reducing the uncertainty in ρ s estimation compared to SECT. The acquisition of CT data over different x-ray spectra yields additional information on the material elemental composition. Recently, multi-energy CT (MECT) has been explored to deduct material-specific information with higher dimensionality, which has the potential to further improve the accuracy of ρ s estimation. Even though various DECT and MECT methods have been proposed and evaluated over the years, these approaches are still only scarcely implemented in routine clinical practice. In this topical review, we aim at accelerating this translation process by providing: (1) a comprehensive review of the existing DECT/MECT methods for ρ s estimation with their respective strengths and weaknesses; (2) a general review of uncertainties associated with DECT/MECT methods; (3) a general review of different aspects related to clinical implementation of DECT/MECT methods; (4) other potential advanced DECT/MECT applications beyond ρ s estimation.
- 6 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (4) , 04TR01
Open AccessDual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential
Range uncertainty has been a key factor preventing particle radiotherapy from reaching its full physical potential. One of the main contributing sources is the uncertainty in estimating particle stopping power (ρ s ) within patients. Currently, the ρ s distribution in a patient is derived from a single-energy CT (SECT) scan acquired for treatment planning by converting CT number expressed in Hounsfield units (HU) of each voxel to ρ s using a Hounsfield look-up table (HLUT), also known as the CT calibration curve. HU and ρ s share a linear relationship with electron density but differ in their additional dependence on elemental composition through different physical properties, i.e. effective atomic number and mean excitation energy, respectively. Because of that, the HLUT approach is particularly sensitive to differences in elemental composition between real human tissues and tissue surrogates as well as tissue variations within and among individual patients. The use of dual-energy CT (DECT) for ρ s prediction has been shown to be effective in reducing the uncertainty in ρ s estimation compared to SECT. The acquisition of CT data over different x-ray spectra yields additional information on the material elemental composition. Recently, multi-energy CT (MECT) has been explored to deduct material-specific information with higher dimensionality, which has the potential to further improve the accuracy of ρ s estimation. Even though various DECT and MECT methods have been proposed and evaluated over the years, these approaches are still only scarcely implemented in routine clinical practice. In this topical review, we aim at accelerating this translation process by providing: (1) a comprehensive review of the existing DECT/MECT methods for ρ s estimation with their respective strengths and weaknesses; (2) a general review of uncertainties associated with DECT/MECT methods; (3) a general review of different aspects related to clinical implementation of DECT/MECT methods; (4) other potential advanced DECT/MECT applications beyond ρ s estimation.
- Open Access
- 1 December 2021
- Published by Elsevier in Physica Medica
- Vol. 92, S81-S82
Predicting breathing target motion from a surrogate signal during radiotherapy: a Bayesian approach
- 1 December 2021
- Published by Elsevier in Physica Medica
- Vol. 92, S81-S82
Open AccessPredicting breathing target motion from a surrogate signal during radiotherapy: a Bayesian approach
- 1 February 2021
- Published by Wiley in Medical Physics
- Vol. 48 (5) , 2592-2603
Eigencolor radiochromic film dosimetry
Purpose: The goal of this work is to propose a new multichannel method correcting for systematic thickness disturbances and to evaluate its precision in relevant radiation dosimetry applications.Methods: The eigencolor ratio technique is introduced and theoretically developed to provide a method correcting for thickness disturbances. The method is applied to EBT3 GafchromicTM film irradiated with cobalt‐60 and 6 MV photon beams and digitized with an Epson 10000XL photo scanner. Dose profiles and output factors of different field sizes are measured and analyzed. Variance analysis of the previous method of Bouchard et al. [“On the characterization and uncertainty analysis of radiochromic film dosimetry” Med Phys. 2009;36:1931‐1946] is adapted to the new approach. Uncertainties are predicted for relevant applications.Results: Results show that systematic disturbances attributed to thickness variations are efficiently corrected. The method is shown efficient to identify and correct for dark spots which cause systematic errors in single‐channel distributions. Applications of the method in the context of relative dosimetry yields standard uncertainties ranging between 0.8% and 1.9%, depending on the region of interest (ROI) size and the film irradiation. Variance analysis predicts that uncertainty levels between 0.3% and 0.6% are achievable with repeated measurements. Uncertainties are found to vary with absorbed dose and ROI size.Conclusions: The proposed multichannel method is efficient for accurate dosimetry, reaching uncertainty levels comparable to previous publications with EBT film. The method is also promising for applications beyond clinical QA, such as machine characterization and other advanced dosimetry applications.
- 1 February 2021
- Published by Wiley in Medical Physics
- Vol. 48 (5) , 2592-2603
Eigencolor radiochromic film dosimetry
Purpose: The goal of this work is to propose a new multichannel method correcting for systematic thickness disturbances and to evaluate its precision in relevant radiation dosimetry applications.Methods: The eigencolor ratio technique is introduced and theoretically developed to provide a method correcting for thickness disturbances. The method is applied to EBT3 GafchromicTM film irradiated with cobalt‐60 and 6 MV photon beams and digitized with an Epson 10000XL photo scanner. Dose profiles and output factors of different field sizes are measured and analyzed. Variance analysis of the previous method of Bouchard et al. [“On the characterization and uncertainty analysis of radiochromic film dosimetry” Med Phys. 2009;36:1931‐1946] is adapted to the new approach. Uncertainties are predicted for relevant applications.Results: Results show that systematic disturbances attributed to thickness variations are efficiently corrected. The method is shown efficient to identify and correct for dark spots which cause systematic errors in single‐channel distributions. Applications of the method in the context of relative dosimetry yields standard uncertainties ranging between 0.8% and 1.9%, depending on the region of interest (ROI) size and the film irradiation. Variance analysis predicts that uncertainty levels between 0.3% and 0.6% are achievable with repeated measurements. Uncertainties are found to vary with absorbed dose and ROI size.Conclusions: The proposed multichannel method is efficient for accurate dosimetry, reaching uncertainty levels comparable to previous publications with EBT film. The method is also promising for applications beyond clinical QA, such as machine characterization and other advanced dosimetry applications.
- 1 November 2020
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 108 (3) , e366-e367
Evaluation of Radiation Dose Effect on Lung Function Using Iodine Maps Derived from Serial Dual-Energy Computed Tomograms
- 1 November 2020
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 108 (3) , e366-e367
Evaluation of Radiation Dose Effect on Lung Function Using Iodine Maps Derived from Serial Dual-Energy Computed Tomograms
- Open Access
- 12 July 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (16) , 165007
Optimized I-values for use with the Bragg additivity rule and their impact on proton stopping power and range uncertainty
Purpose: Novel imaging modalities estimate patient elemental compositions for particle treatment planning. The mean excitation energy (I-value) is a main contributor to the proton range uncertainty. To minimize their impact on beam range errors and quantify their uncertainties, the currently used I-values proposed in 1982 are revisited. The study aims at proposing a new set of optimized elemental I-values for use with the Bragg additivity rule (BAR) and establishing uncertainties on optimized I-values and the BAR. Methods: We optimize elemental I-values for the use in compounds based on measured material I-values. We gain a new set of elemental I-values and corresponding uncertainties, based on the experimental uncertainties and our uncertainty model. We evaluate uncertainties on I-values and relative stopping powers (RSP) of 70 human tissues, taking into account statistical correlations between tissues and water. The effect of new I-values on proton beam ranges is quantified using Monte Carlo simulations. Results: Our elemental I-values describe measured material I-values with higher accuracy than ICRU-recommended I-values (RMSE: 6.17% (ICRU), 5.19% (this work)). Our uncertainty model estimates an uncertainty component from the BAR to 4.42%. Using our elemental I-values, we calculate the I-value of water as 78.73+/-2.89 eV, being consistent with ICRU 90 (78+/-2 eV). We observe uncertainties on tissue I-values between 1.82-3.38 eV, and RSP uncertainties between 0.002%-0.44%. With transport simulations of a proton beam in human tissues, we observe range uncertainties between 0.31% and 0.47%, as compared to current estimates of 1.5%. Conclusion: We propose a set of elemental I-values well suited for human tissues in combination with the BAR. Our model establishes uncertainties on elemental I-values and the BAR, enabling to quantify uncertainties on tissue I-values, RSP as well as particle range. This work is particularly relevant for Monte Carlo simulations where the interaction probabilities are reconstructed from elemental compositions.
- 12 July 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (16) , 165007
Open AccessOptimized I-values for use with the Bragg additivity rule and their impact on proton stopping power and range uncertainty
Purpose: Novel imaging modalities estimate patient elemental compositions for particle treatment planning. The mean excitation energy (I-value) is a main contributor to the proton range uncertainty. To minimize their impact on beam range errors and quantify their uncertainties, the currently used I-values proposed in 1982 are revisited. The study aims at proposing a new set of optimized elemental I-values for use with the Bragg additivity rule (BAR) and establishing uncertainties on optimized I-values and the BAR. Methods: We optimize elemental I-values for the use in compounds based on measured material I-values. We gain a new set of elemental I-values and corresponding uncertainties, based on the experimental uncertainties and our uncertainty model. We evaluate uncertainties on I-values and relative stopping powers (RSP) of 70 human tissues, taking into account statistical correlations between tissues and water. The effect of new I-values on proton beam ranges is quantified using Monte Carlo simulations. Results: Our elemental I-values describe measured material I-values with higher accuracy than ICRU-recommended I-values (RMSE: 6.17% (ICRU), 5.19% (this work)). Our uncertainty model estimates an uncertainty component from the BAR to 4.42%. Using our elemental I-values, we calculate the I-value of water as 78.73+/-2.89 eV, being consistent with ICRU 90 (78+/-2 eV). We observe uncertainties on tissue I-values between 1.82-3.38 eV, and RSP uncertainties between 0.002%-0.44%. With transport simulations of a proton beam in human tissues, we observe range uncertainties between 0.31% and 0.47%, as compared to current estimates of 1.5%. Conclusion: We propose a set of elemental I-values well suited for human tissues in combination with the BAR. Our model establishes uncertainties on elemental I-values and the BAR, enabling to quantify uncertainties on tissue I-values, RSP as well as particle range. This work is particularly relevant for Monte Carlo simulations where the interaction probabilities are reconstructed from elemental compositions.
- 10 May 2018
- Published by Wiley in Medical Physics
- Vol. 45 (5) , 2345-2348
Comment on “Methodological accuracy of image‐based electron‐density assessment using dual‐energy computed tomography” [Med. Phys. 44 (6), 2429‐2437 (2017)]
- 10 May 2018
- Published by Wiley in Medical Physics
- Vol. 45 (5) , 2345-2348
Comment on “Methodological accuracy of image‐based electron‐density assessment using dual‐energy computed tomography” [Med. Phys. 44 (6), 2429‐2437 (2017)]