Pradeep Kumar Sahu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pradeep Kumar Sahu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Satyaranjan Jena
KIIT Deemed to be University
4 shared publications Amiya Kumar Naik
Siksha O Anusandhan (Deemed to be University),ITER,Department of Electrical Engineering,Bhubaneswar,Odisha,India
1 shared publication- Chinmoy Kumar Panigrahi
School of Electrical Engg. KIIT University, Bhubaneswar, Odisha, India
1 shared publication - Geetanjali Dei
School of Electrical Engineering, KIIT Deemed to be University,India
1 shared publication - Jnanaranjan Nayak
Kalinga University
1 shared publication - Neha Singh
Manipal University Jaipur
1 shared publication
Latest Publications
- 17 June 2025
- Published by Springer Nature
- p. 369-380
Power Quality Enhancement of Shunt Active Power Filters by Sliding Mode Control Technique
- 17 June 2025
- Published by Springer Nature
- p. 369-380
Power Quality Enhancement of Shunt Active Power Filters by Sliding Mode Control Technique
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Technoeconomical Analysis of Grid Connected PV System Powered by Battery Implemented in Educational Institute
The increase in energy demand and environmental pollution necessitates the integration of renewable energy sources with the grid. The hike of installation cost of the conventional photovoltaic cells causes to look for better optimized solutions to integrate the PV, energy storage devices and converters with the grid. In this paper the solar PV, energy storage devices are optimized and integrated with grid with reduced NPC (Net Present Cost) and COE (Cost of Energy) in HOMER PRO software to find out the most economically viable solution. Among all the configurations proposed, PV/Grid/Battery system emerges as the most economically viable solution. This system has an NPC of $4.906967 million, a COE of $0.09973, and an overall operating cost of $3.79433 million. The payback period of the above configuration is 7.2 years which is sufficient to recover all the capital cost.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Technoeconomical Analysis of Grid Connected PV System Powered by Battery Implemented in Educational Institute
The increase in energy demand and environmental pollution necessitates the integration of renewable energy sources with the grid. The hike of installation cost of the conventional photovoltaic cells causes to look for better optimized solutions to integrate the PV, energy storage devices and converters with the grid. In this paper the solar PV, energy storage devices are optimized and integrated with grid with reduced NPC (Net Present Cost) and COE (Cost of Energy) in HOMER PRO software to find out the most economically viable solution. Among all the configurations proposed, PV/Grid/Battery system emerges as the most economically viable solution. This system has an NPC of $4.906967 million, a COE of $0.09973, and an overall operating cost of $3.79433 million. The payback period of the above configuration is 7.2 years which is sufficient to recover all the capital cost.
- Open Access
- 1 June 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 13 (2) , 294-302
Analysis, design, and control of standalone PV based boost DC-AC converter
This paper presents a new control scheme for a boost DC–AC converter which is used for solar power applications. The proposed DC-AC converter configuration can produce an AC voltage level across the output or load side greater than input DC voltage based on the operating duty cycle. Generally, the conventional DC-AC converter or voltage source inverter (VSI) generates AC voltage which is less than input DC voltage. Maintaining a constant voltage across the load with improved dynamic performance is challenging for anyone for the solar photovoltaic (PV) system. A dual-loop sliding mode control is proposed for the boost VSI to address the above issues. The proposed controller has robust in nature against the wide fluctuation in the plant or load parameters. The design, analysis and control of the boost DC-AC converter are briefly discussed in this paper. This topology can be broadly used in solar powered uninterruptible power supply (UPS) where boosting operation is essential for low voltage solar PV system. This topology eliminates the DC boosting power processing stage which leads an improved efficiency of the overall system. The MATLAB/Simulink results are presented to highlight the above issues.
- 1 June 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 13 (2) , 294-302
Open AccessAnalysis, design, and control of standalone PV based boost DC-AC converter
This paper presents a new control scheme for a boost DC–AC converter which is used for solar power applications. The proposed DC-AC converter configuration can produce an AC voltage level across the output or load side greater than input DC voltage based on the operating duty cycle. Generally, the conventional DC-AC converter or voltage source inverter (VSI) generates AC voltage which is less than input DC voltage. Maintaining a constant voltage across the load with improved dynamic performance is challenging for anyone for the solar photovoltaic (PV) system. A dual-loop sliding mode control is proposed for the boost VSI to address the above issues. The proposed controller has robust in nature against the wide fluctuation in the plant or load parameters. The design, analysis and control of the boost DC-AC converter are briefly discussed in this paper. This topology can be broadly used in solar powered uninterruptible power supply (UPS) where boosting operation is essential for low voltage solar PV system. This topology eliminates the DC boosting power processing stage which leads an improved efficiency of the overall system. The MATLAB/Simulink results are presented to highlight the above issues.
- Open Access
- 1 February 2023
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 13 (1) , 10060-10066
Technoeconomic Analysis of a Hybrid Energy System for an Academic Building
This work is mainly based on the optimal design of a standalone Hybrid Renewable Energy System (HRES) consisting of PV/diesel/battery systems, implemented in an academic building. Different hybrid system configurations such as PV-diesel generator-battery, diesel generator-battery, and PV-diesel generator are compared based on Net Present Cost (NPC) and Cost Of Energy (COE) to find out the best economically viable and environmentally friendly solution. Li-ion and lead-acid batteries were taken into consideration, and the optimization was done in HOMER PRO software. The PV-DG-Li-ion battery configuration emits approximately 2825387kg/year CO2 whereas the conventional DG system emits 4565074kg/year. It is concluded that the PV-DG-Li-ion battery configuration provides the cleanest and most environment-friendly and techno-economically feasible solution.
- 1 February 2023
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 13 (1) , 10060-10066
Open AccessTechnoeconomic Analysis of a Hybrid Energy System for an Academic Building
This work is mainly based on the optimal design of a standalone Hybrid Renewable Energy System (HRES) consisting of PV/diesel/battery systems, implemented in an academic building. Different hybrid system configurations such as PV-diesel generator-battery, diesel generator-battery, and PV-diesel generator are compared based on Net Present Cost (NPC) and Cost Of Energy (COE) to find out the best economically viable and environmentally friendly solution. Li-ion and lead-acid batteries were taken into consideration, and the optimization was done in HOMER PRO software. The PV-DG-Li-ion battery configuration emits approximately 2825387kg/year CO2 whereas the conventional DG system emits 4565074kg/year. It is concluded that the PV-DG-Li-ion battery configuration provides the cleanest and most environment-friendly and techno-economically feasible solution.
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Performance analysis of single-phase grid interactive voltage source inverter using different filter
In the current scenario the penetration of renewable energy sources to the existing grid increases in order meet the increasing load demand. Most of the renewable sources are interconnected to the grid through pulse width modulated (PWM) voltage source inverter as the outputs of the renewable are intermittent in nature. For proper synchronization of the renewable with the grid different current control techniques are used to control the output parameters of the pulse width modulated inverter. These PWM inverter injects harmonics to the system which should be filter out before synchronization according to grid code compliance. Most of the cases a simple L filter or a LCL filter is used to suppress the harmonics. In this paper a LLCL filter is used which can suppress the current ripple at switching frequency therefore the total harmonic distortion is low as compared to the other filter. The system is simulated in MATLAB-Simulink environment.
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Performance analysis of single-phase grid interactive voltage source inverter using different filter
In the current scenario the penetration of renewable energy sources to the existing grid increases in order meet the increasing load demand. Most of the renewable sources are interconnected to the grid through pulse width modulated (PWM) voltage source inverter as the outputs of the renewable are intermittent in nature. For proper synchronization of the renewable with the grid different current control techniques are used to control the output parameters of the pulse width modulated inverter. These PWM inverter injects harmonics to the system which should be filter out before synchronization according to grid code compliance. Most of the cases a simple L filter or a LCL filter is used to suppress the harmonics. In this paper a LLCL filter is used which can suppress the current ripple at switching frequency therefore the total harmonic distortion is low as compared to the other filter. The system is simulated in MATLAB-Simulink environment.
- 30 April 2021
- Published by Elsevier
- p. 405-422
Efficient wireless power transfer system for biomedical applications
- 30 April 2021
- Published by Elsevier
- p. 405-422
Efficient wireless power transfer system for biomedical applications
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Design and Analysis of Sliding Mode Control for Single-Phase VSI
It is necessary to retain a reasonable voltage control and to achieve a fast-dynamic response under abrupt load variations in the uninterruptible power source (UPS). This paper suggests a modern voltage source inverter (VSI) referring to as a single-phase SM-controlled VSI. For the intent of maximizing the inverter dynamics, although maintaining optimal service under any operating situation a sliding mode control (SMC) with a proportional-integral (PI) controller is proposed. The main benefits of SMC are its robustness and dynamic performance which leads to a steady-state response. SMC is simple to use as compared to other non-linear controllers. However, the THD of inverter's output of linear load is 0.22% whereas THD of non-linear is 3.84%. This paper includes operation, analysis, control strategy and experimental results. The result shows the good performance of proposed controller. The simulated results represented for step load in voltage and current. The new inverter can be used with a UPS and ac drivers.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Design and Analysis of Sliding Mode Control for Single-Phase VSI
It is necessary to retain a reasonable voltage control and to achieve a fast-dynamic response under abrupt load variations in the uninterruptible power source (UPS). This paper suggests a modern voltage source inverter (VSI) referring to as a single-phase SM-controlled VSI. For the intent of maximizing the inverter dynamics, although maintaining optimal service under any operating situation a sliding mode control (SMC) with a proportional-integral (PI) controller is proposed. The main benefits of SMC are its robustness and dynamic performance which leads to a steady-state response. SMC is simple to use as compared to other non-linear controllers. However, the THD of inverter's output of linear load is 0.22% whereas THD of non-linear is 3.84%. This paper includes operation, analysis, control strategy and experimental results. The result shows the good performance of proposed controller. The simulated results represented for step load in voltage and current. The new inverter can be used with a UPS and ac drivers.