Geetanjali Dei
Geetanjali Dei has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Satyabrata Sahoo
School of Electrical Engineering, KIIT Deemed to be University,India
2 shared publications Anasuya Roy Choudhury
Siksha O Anusandhan deemed to be University,Department of Electrical Engineering,Bhubaneswar,India
1 shared publication- Binod Kumar Sahu
Department of Electrical Engineering, FET, ITER, Siksha ‘O’ Anusandhan Deemed to be University, Bhubaneswar, India
1 shared publication - Deepak Kumar Gupta
Netaji Subhas University of Technology
1 shared publication - Kaushik Paul
Department of Electrical Engineering, BIT Sindri, Dhanbad 828123, India
1 shared publication - Narayan Nahak
Siksha ‘O’Anusandhan Deemed to Be University
1 shared publication
Latest Publications
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Technoeconomical Analysis of Grid Connected PV System Powered by Battery Implemented in Educational Institute
The increase in energy demand and environmental pollution necessitates the integration of renewable energy sources with the grid. The hike of installation cost of the conventional photovoltaic cells causes to look for better optimized solutions to integrate the PV, energy storage devices and converters with the grid. In this paper the solar PV, energy storage devices are optimized and integrated with grid with reduced NPC (Net Present Cost) and COE (Cost of Energy) in HOMER PRO software to find out the most economically viable solution. Among all the configurations proposed, PV/Grid/Battery system emerges as the most economically viable solution. This system has an NPC of $4.906967 million, a COE of $0.09973, and an overall operating cost of $3.79433 million. The payback period of the above configuration is 7.2 years which is sufficient to recover all the capital cost.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Technoeconomical Analysis of Grid Connected PV System Powered by Battery Implemented in Educational Institute
The increase in energy demand and environmental pollution necessitates the integration of renewable energy sources with the grid. The hike of installation cost of the conventional photovoltaic cells causes to look for better optimized solutions to integrate the PV, energy storage devices and converters with the grid. In this paper the solar PV, energy storage devices are optimized and integrated with grid with reduced NPC (Net Present Cost) and COE (Cost of Energy) in HOMER PRO software to find out the most economically viable solution. Among all the configurations proposed, PV/Grid/Battery system emerges as the most economically viable solution. This system has an NPC of $4.906967 million, a COE of $0.09973, and an overall operating cost of $3.79433 million. The payback period of the above configuration is 7.2 years which is sufficient to recover all the capital cost.
- Open Access
- 31 January 2024
- Published by Frontiers Media SA in Frontiers in Smart Grids
- Vol. 3, 1338774
Identification of harmonic sources in smart grid using systematic feature extraction from non-active powers
The paper introduces a novel method for identifying the location of harmonic-generating sources in smartgrids. The method utilizes a Dual-Tree Complex Wavelet Transform (DTCWT) of voltage and current signals measured at a specific point in the network. By applying DTCWT Transform, the signals are decomposed, and three non-active power quantities are extracted to represent the harmonic components within the system exclusively. These chosen non-active power quantities serve as indicators of the presence of harmonics in the system. Through analysis and comparison of these quantities, the method enables determining the precise location of the dominant harmonic generating source. This information is valuable for effectively addressing and mitigating harmonic issues in the network. Leveraging DTCWT and focusing on non-active power quantities provides a valuable tool for power system engineers and operators to diagnose and mitigate harmonic issues, ultimately improving power quality and system performance. This study presents a new feature extraction method to compute Non-active power quantities based on DTCWT due to its shift-invariant property.
- 31 January 2024
- Published by Frontiers Media SA in Frontiers in Smart Grids
- Vol. 3, 1338774
Open AccessIdentification of harmonic sources in smart grid using systematic feature extraction from non-active powers
The paper introduces a novel method for identifying the location of harmonic-generating sources in smartgrids. The method utilizes a Dual-Tree Complex Wavelet Transform (DTCWT) of voltage and current signals measured at a specific point in the network. By applying DTCWT Transform, the signals are decomposed, and three non-active power quantities are extracted to represent the harmonic components within the system exclusively. These chosen non-active power quantities serve as indicators of the presence of harmonics in the system. Through analysis and comparison of these quantities, the method enables determining the precise location of the dominant harmonic generating source. This information is valuable for effectively addressing and mitigating harmonic issues in the network. Leveraging DTCWT and focusing on non-active power quantities provides a valuable tool for power system engineers and operators to diagnose and mitigate harmonic issues, ultimately improving power quality and system performance. This study presents a new feature extraction method to compute Non-active power quantities based on DTCWT due to its shift-invariant property.
- 16 December 2021
- Published by Springer Nature
- p. 403-414
Symbiotic Organism Search (SOS) Algorithm Based Load Frequency Control for Hybrid Power System
- 16 December 2021
- Published by Springer Nature
- p. 403-414
Symbiotic Organism Search (SOS) Algorithm Based Load Frequency Control for Hybrid Power System
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Tuning of governor and damping controller parameters of hydro power station for small signal stability enhancement
It proposes optimal setting of an auxiliary power oscillation damping controller (POD) along with governor controller parameters of a hydroelectric power station to enhance small signal stability of power network pertaining to damp out oscillations of low frequencies. DE-PSO, a Hybrid technique is being employed to tune governor controller gains. The considered disturbance is the step change in mechanical input power. Different case studies have been presented on ITAE based objective function. It has been observed that auxiliary POD can increase the performance of governor. With proposed optimal POD and governor controller setting of parameters the oscillations are damped heavily. The effect of control action has been justified with eigen value analysis and damping parameters obtained with different cases. Small signal models of generator and Woodward governor have been implemented in this work.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Tuning of governor and damping controller parameters of hydro power station for small signal stability enhancement
It proposes optimal setting of an auxiliary power oscillation damping controller (POD) along with governor controller parameters of a hydroelectric power station to enhance small signal stability of power network pertaining to damp out oscillations of low frequencies. DE-PSO, a Hybrid technique is being employed to tune governor controller gains. The considered disturbance is the step change in mechanical input power. Different case studies have been presented on ITAE based objective function. It has been observed that auxiliary POD can increase the performance of governor. With proposed optimal POD and governor controller setting of parameters the oscillations are damped heavily. The effect of control action has been justified with eigen value analysis and damping parameters obtained with different cases. Small signal models of generator and Woodward governor have been implemented in this work.