Il Sook Seo has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical and radiographic outcomes of elastic stable intramedullary nailing for pediatric humeral shaft fractures: a retrospective case series

    by Kang-San Lee, Dongju Shin, Sang Hee Kim, Il Seo, Tae-Hoon Kim, Sung Jung Kim

    Background: Pediatric humeral shaft fractures are uncommon and are generally treated conservatively, with satisfactory clinical outcomes reported in most cases. However, conservative management often necessitates prolonged immobilization and frequent outpatient follow-up visits, and it carries an inherent risk of residual angular or translational deformity. Elastic stable intramedullary nailing (ESIN) provides a simple and minimally invasive method of fracture fixation that offers adequate stability without disrupting the periosteal blood supply, thereby permitting early mobilization and promoting rapid bone union. The purpose of this study was to evaluate the clinical and radiological outcomes of ESIN fixation in pediatric patients with humeral shaft fractures.Methods: The medical records of pediatric patients with humeral shaft fractures who underwent ESIN fixation between January 2015 and November 2025 were retrospectively reviewed. Data collected included patient demographics, mechanism of injury, fracture location, number of elastic nails used, time to union, degree of residual angulation, range of motion (ROM), and postoperative complications.Results: The mean age of the patients was 10.0 years (range, 7 to 15 years). The mean time to radiographic union was 5.4 weeks (range, 2.4 to 10.4 weeks). The mean coronal angulation was 0.2° (range, −9.1° to 5.8°), while the mean sagittal angulation was −1.3° (range, −6.9° to 5.3°). No cases of infection, nerve injury, or nail migration were observed during the follow-up period. At the final follow-up assessment, all patients demonstrated full shoulder and elbow ROM, with no residual deformity or pain reported.Conclusions: In this small retrospective case series, ESIN fixation resulted in favorable union rates and excellent functional outcomes in pediatric humeral shaft fractures.Level of evidence: IV.

  • Open Access

    Extension block pinning combined with traction using towel clamps for effective reduction of mallet fracture: a technical tip

    by Il Seo, Kang-San Lee, Seungho Chung, Sang-Woo Son, Hyun-Joo Lee

    Purpose: Although closed reduction and extension block pinning have been widely used for acute mallet finger fracture, the problem of reduction remains a concern. We describe a tip for the reduction technique using a towel clamp, which provides a longitudinal traction force to the distal phalanx, and report the results of the technique.Methods: The medical records of 14 consecutive cases from 12 patients with acute mallet fractures were retrospectively reviewed. Reduction was achieved using the towel clamp reduction technique. The radiologic results were evaluated by simple radiographs, the functional results were analyzed in terms of range of motion, and remaining pain was assessed using Crawford criteria.Results: The mean follow-up period was 8.4 months. The mean union duration was 6 weeks. The mean range of motion was 73°. Eight cases had excellent outcomes, one had good outcomes, four had fair outcomes, and one had poor outcomes. One case of superficial infection and one case of skin necrosis developed, and three cases showed arthritic changes in the distal interphalangeal joint.Conclusion: The towel clamp technique can provide good reduction during surgery, with favorable radiologic and clinical results.


  • Open Access

    Minimally Invasive Derotational Osteotomy of Long Bones: Smartphone Application Used to Improve the Accuracy of Correction

    by Chang-Wug Oh, Kyeong-Hyeon Park, Joon-Woo Kim, Dong-Hyun Kim, Il Seo, Jin-Han Lee, Ji-Wan Kim, Sung-Hyuk Yoon

    Correction of rotational malalignments caused by fractures is essential as it may cause pain and gait disturbances. This study evaluated the intraoperative use of a smartphone application (SP app) to measure the extent of corrective rotation in patients treated using minimally invasive derotational osteotomy. Intraoperatively, two parallel 5 mm Schanz pins were placed above and below the fractured/injured site, and derotation was performed manually after percutaneous osteotomy. A protractor SP app was used intraoperatively to measure the angle between the two Schanz pins (angle-SP). Intramedullary nailing or minimally invasive plate osteosynthesis was performed after derotation, and computerized tomography (CT) scans were used to assess the angle of correction postoperatively (angle-CT). The accuracy of rotational correction was assessed by comparing angle-SP and angle-CT. The mean preoperative rotational difference observed was 22.1°, while the mean angle-SP and angle-CT were 21.6° and 21.3°, respectively. A significant positive correlation between angle-SP and angle-CT was observed, and 18 out of 19 patients exhibited complete healing within 17.7 weeks (1 patient exhibited nonunion). These findings suggest that using an SP app during minimally invasive derotational osteotomy can result in accurate correction of malrotation of long bones in a reproducible manner. Therefore, SP technology with integrated gyroscope function represents a suitable alternative for determination of the magnitude of rotational correction when performing corrective osteotomy.


  • Open Access

    Management of Perioperative Hypothermia

    by Il Sook Seo

    Anesthesia and surgery commonly cause substantial thermal perturbations. Mild hypothermia (33.0∼36.4℃) results from a combination of anesthetic-induced impairment of thermoregulatory control, a cool operating room environment, and factors unique to surgery that promote excessive heat loss. Perioperative mild hypothermia is extremely common and associated with adverse outcomes such as excessive sympathetic nervous system stimulation, prolonged drug metabolism, impaired platelet activity, impaired immune function and postanesthetic shivering. Prevention of perioperative hypothermia and post-anesthetic shivering improves the outcome in terms of reduced cardiac morbidity and blood loss, improved wound healing and shorter hospital stay. Core temperature monitoring, accompanied by passive and active methods to maintain normothermia, should be part of routine intraoperative monitoring for patients at high risk of perioperative hypothermia, particularly patients undergoing body-cavity surgery, surgery greater than 1 hour duration, younger children and the elderly. 1)


  • Open Access

    The Effect of Lesser Palatine Nerve Block on Pain after Elective Pediatric Tonsillectomy

    by Hyo Jung Kim, Sun Ok Song, Chang Hoon Lee, Yoon Suk Son, Il Sook Seo, Sae Yeon Kim

    Kim HJ, et al. Korean J Anesthesiol. 2003 Jun;44(6):820-827. http://dx.doi.org/10.4097/kjae.2003.44.6.820

  • Open Access

    Proper Respiratory Rate during Mechanical Ventilation in Pediatric General Anesthesia

    by Il Sook Seo, Yong Hwan Lee, Sae Yeon Kim

    Seo IS, et al. Korean J Anesthesiol. 2002 Oct;43(4):451-456. http://dx.doi.org/10.4097/kjae.2002.43.4.451