OBOlga Bedratiuk

Olga Bedratiuk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Olga Bedratiuk has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Identifying patterns of change in fire protection of the tent fabric treated with an epoxy resin-based intumescent coating

    by Yuriy Tsapko, Oksana Berdnyk, Aleksii Tsapko, Ruslan Likhnyovskyi, Tetiana Nehrii, Oksana Kasianova, Yurii Feshchuk, Vasyl Lomaha, Olga Bedratiuk, Kseniia Bielikova

    This study investigates the process of forming a fire-retardant coating based on modified epoxy resin on the surface of tent fabric. The task addressed is to ensure fire protection of tent fabric when treated with a coating based on modified epoxy resin. This is important given the relevance of fire-resistant materials for modern construction. It has been proven that when treating tent fabric with epoxy resin, the free energy component of the fabric surface decreased by more than 2.3 times, while the polar component increased by 1.6 times, which indicates a change in the surface. At the same time, the tensile strength of tent fabric after treatment with epoxy resin increased by more than 4.1 times. The study has shown that a sample of tent fabric caught fire when exposed to a burner flame for 5 s and continued to burn for 16 s when the ignition source was removed. The treatment of tent fabric with epoxy resin with flame retardant led to the formation of charring on the sample with a length of more than 70 mm, and the height of the swelling in the flame zone was about 3 ÷ 5 mm. When testing tent fabric samples for the flame spread index, it was found that the sample treated with epoxy resin caught fire in 524 s, the flame spread throughout the sample for 14 s, the burning length of the sample was 300 mm, and the flammability index was 36.3. However, for samples treated with epoxy resin filled with a mixture of ammonium polyphosphate and aluminum hydroxide, the flammability indices decreased by more than 30 times. The optimal concentration of components in the coating containing 34 ÷ 35% (wt.) of ammonium polyphosphate and 9 ÷ 10% (wt.) of aluminum hydroxide has been determined. Thus, there are grounds for the possibility of designing fire-resistant coatings for construction

  • Open Access

    RESEARCH OF THE FIRE-EXTINGUISHING CAPACITY OF A WATER-BASED FIRE-PROTECTIVE AGENT BASED ON POLYACRYLATE AND POLYACRYLAMIDE POLYMERS

    by Ігор Стилик, Анатолій Кодрик, Марія Куценко, Ольга Бедратюк, Igor Stylyk, Anatoly Kodryk, Maria Kutsenko

    The article presents the results of a study on the fire-extinguishing capacity of a water-based fire-protective agent modified with a complex of polymer additives based on acrylates. The relevance of the research is driven by the need to improve the efficiency of extinguishing fires involving liquid and solid combustible materials, to reduce water consumption, and to minimize the risk of re-ignition. The authors analyzed the current state of polymer gel applications in fire suppression practice and highlighted their key advantages — high water retention capacity, the ability to form a protective gel film on the burning surface, low thermal conductivity, and the capacity to create an insulating barrier that prevents oxygen access. The study examined compositions derived from two types of polymer gel-forming substances: insoluble absorbent types such as Ecofloc A-07, which form swollen gel particles when hydrated, and water-soluble high-molecular-weight types such as Ecofloc A-18 and Ecofloc A-25, which influence the viscosity of the solution and impart thixotropic properties. The effects of polymer composition and concentration, as well as additional surfactants and stabilizers, on the rheological and fire-extinguishing characteristics of the mixtures were determined. The experimental part of the research focused on evaluating the fire-extinguishing effectiveness of the proposed solutions when extinguishing transformer oil fires. A metal tray with an area of 4 m² and a fuel layer thickness of 20 mm was used; the oil and flame temperatures were recorded using thermocouples and a thermal imaging camera. It was found that the transformer oil heated up to 155 °C, creating conditions under which the use of water is hazardous due to the likelihood of steam explosions and splattering of overheated liquid. The application of the polymer gel composition provided a stable cooling and insulating effect, ensured uniform surface coverage, and gradually reduced the temperature to a level incompatible with sustained combustion. The mass flow rate (0.125 kg/s) and application intensity (0.0312 kg/(s·m²)) were determined, providing effective disruption of the flame zone and preventing re-ignition. The results confirmed the efficiency of using polymer-modified gel fire-extinguishing agents for suppressing fires involving petroleum-based dielectric liquids such as transformer oil.

  • Open Access

    МЕТОДИКА ЕКСПЕРИМЕНТАЛЬНИХ ДОСЛІДЖЕНЬ ПОШИРЕННЯ ПОЛУМ’Я ТА ТЕМПЕРАТУРНОГО ВПЛИВУ ПОЖЕЖІ В ПРИМІЩЕННІ БАЗОВОЇ СТАНЦІЇ МОБІЛЬНОГО ЗВЯЗКУ

    by Юрій Фещук, Андрій Циганков, Владислав Мельник, Ольга Бедратюк, Катерина Шевченко

    Виявлено проблему щодо економічної недоцільності оснащення приміщень базової станції мобільного зв’язку автоматичними системами пожежогасіння з точки зору захисту обладнання. Встановлено неузгодженості між вимогами ДБН В.2.5-56:2014 та НАПБ В.01.053-2016/520. Визначено найбільш пожежонебезпечні елементи приміщення базової станції мобільного зв’язку. Розроблено критерії оцінювання пожежної небезпеки базової станції мобільного зв’язку, а також сформовано перелік обладнання, що необхідне для проведення експериментальних досліджень. Запропоновано схему розташування термопар, яка найбільш точно відображає знаходження пожежо-небезпечних елементів, дає змогу здійснювати контроль температури в реальному часі та виявляти можливість займання одного елемента внаслідок горіння іншого, встановлювати можливість розповсюдження пожежі за межі приміщення базової станції мобільного зв’язку. Представлено методику, що дає можливість виконати перевірку запропонованих критеріїв з метою дослідження поширення полум’я по телекомунікаційному, електротехнічному обладнанню базової станції мобільного зв’язку та температурного впливу пожежі в приміщенні базової станції на температуру її зовнішніх стін.

  • Open Access

    Establishing patterns in eliminating coal fire sites with nitrogen-air mixtures

    by Yuriy Tsapko, Tetiana Tkachenko, Oksana Kasianova, Аleksii Tsapko, Ruslan Likhnyovskyi, Yuliia Bereznutska, Vitally Prisyazhnuk, Oksana Slutska, Olga Bedratiuk

    The object of this study was the value of nitrogen concentration at which the combustion process of anthracite is effectively inhibited. Therefore, the problem of eliminating the sites of self-ignition of coal relates to ventilating the pile with nitrogen, but it is necessary to take into account the required concentration of inert gas. It has been proven that on the basis of experimental studies of the process of inhibition of combustion when washing an anthracite batch with gaseous nitrogen, a sample of heated coal in a normal air atmosphere continues to burn with greater intensity. An increase in temperature by an average of 20 °C was recorded for 40–45 s. Adding nitrogen to the air in an amount of 12.85 % reduces the combustion temperature of anthracite by 2 %, but the cooling time of combustion below the ignition temperature exceeds 120 s. For a nitrogen-air mixture with a nitrogen concentration of 23.81 %, a decrease in the combustion temperature of the sample below its ignition for 120 s was recorded. Further increase in the amount of nitrogen in the nitrogen-air mixture to 28.57 % more effectively cools the combustion of anthracite below the ignition temperature for 70 s. The results showed that with an increase in the concentration of pure nitrogen in the nitrogen-air mixture, the requirements for the purity of nitrogen as a fire extinguishing agent increase. Therefore, it is necessary to introduce it into the i-th nitrogen-oxygen composition in such a concentration that the nitrogen content in the formed mixtures with air in both cases is the same. This is due to the fact that the purity of the nitrogen-oxygen mixture and its fire extinguishing concentration reflect the conditions under which there is the use of nitrogen-oxygen mixtures of a certain composition for fire extinguishing. The practical significance is that the results of determining the fire extinguishing concentration of nitrogen make it possible to establish the operating conditions of coal storage facilities during the elimination of fire sites

  • Open Access

    Establishing patterns in reducing fire-dangerous properties of sip panels fire-protected with reactive coating

    by Yuriy Tsapko, Аleksii Tsapko, Ruslan Likhnyovskyi, Maryna Sukhanevych, Leonid Zapolskiy, Pavlo Illiuchenko, Olga Bedratiuk

    An issue related to using SIP panels for building structures is to ensure their stability and durability during operation in wide ranges. Therefore, the object of research was the change in the properties of wood-polymer material in case of fire and its protection when applied with a reactive coating capable of forming a pinocoke layer under the influence of high temperature on the coating. It has been proven that in the process of thermal action on the fire-resistant coating, the heat insulation process of SIP panels involves the formation of soot-like products on the surface of the material. Thus, under the action of the radiation panel on the surface of the OSB sample, after 120 s of thermal exposure, the process of intensive formation of a layer of foam coke, which thermally insulated the wood-polymer material, began; instead, after the radiation panel was exposed to the fire-resistant polystyrene foam sample, the process of destruction began at a temperature of about 100 °C polystyrene foam. When determining the flammability of a fire-resistant SIP panel, it was established that the temperature of the flue gases during the tests was no more than 110 °C, the length of the damaged sample did not exceed 460 mm. At the same time, the mass loss did not exceed 200 g, and independent combustion of the SIP panel sample did not occur despite the high temperature. According to these data, the SIP panel, fire-resistant with a reaction coating, belongs to group G1 (low flammability) and is a non-flammable material. The practical significance is that the results were taken into account during the design of buildings from SIP panels. So, there are reasons to assert the possibility of targeted regulation of the fire protection processes of SIP panels through the use of reactive coatings capable of forming a protective layer on the surface of the material that inhibits the rate of heat transfer


  • Open Access

    Determining thermal and physical characteristics of wood polymer material for pipeline thermal insulation

    by Yuriy Tsapko, Ivan Kasianchuk, Ruslan Likhnyovskyi, Аleksii Tsapko, Vitalii Kovalenko, Vadym Nizhnyk, Olga Bedratiuk, Maryna Sukhanevych

    One of the methods for ensuring the efficiency of pipelines for transporting heat-carriers during operation is their thermal insulation, which inhibits heat transfer processes and does not affect environmental indicators. Therefore, the object of research was wood, a polymer material made by polymerization of wood sawdust and dry mixtures of synthetic resins for thermal insulation of pipelines. It has been proven that in the process of thermal action on the heat insulating layer of wood polymer material, the process of heat inhibition involves the formation of pores. This is due to the fact that the thermal conductivity of the material depends on the volumetric mass, the decrease of which for a wood polymer product leads to a decrease in thermal conductivity. In this regard, the simulation of the process of heat transfer through a cylindrical heat-insulating layer made of wood of polymer material was carried out and the dependences derived, which allow obtaining a change in the dynamics of heat transfer and determining thermophysical properties. According to the experimental data and the established dependences, it was found that the thermal conductivity of the wood of the polymer material was within 2.4÷2.9·10-8 m2/s, the thermal conductivity of the sample did not exceed 0.030 W/(m∙K). In addition, the heat capacity of the product corresponds to a value of more than 1034÷1145 kJ/(kg·K) depending on the thickness, which accordingly categorizes it as a heat-insulating material. At the same time, data on thermal insulation properties for polyurethane foam show that when it is used with a density of 100 kg/m3, the thermal conductivity is 0.029 W/(m∙K), which is approximately the same as the value of the proposed wood polymer material. The practical value is the fact that the results of determining the heat-insulating properties of a wood polymer material make it possible to establish the scope and conditions of its application