DCDaniel A. Ciraula

Daniel A. Ciraula

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel A. Ciraula has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Constraining time-lapse geophysical responses with reactive transport modelling: an approach to monitor H2S mineral storage

    by Daniel A Ciraula, Gianluca Fiandaca, Jian Chen, Samuel Scott, Léa Lévy

    SUMMARY: Geothermal energy production emits significant amounts of hydrogen sulfide (H$_2$S). A strategy to mitigate the emissions is to reinject the H$_2$S into basaltic formations, where it reacts with the rock to form pyrite. Due to the polarization properties of pyrite, the direct current resistivity (DC) and induced polarization (IP) geophysical method (i.e. DCIP) has shown the potential for monitoring H$_2$S mineral storage. However, field applications of DCIP monitoring have been limited by the low spatial coverage of wireline logging and by the ambiguity in interpreting IP signals due to multiple processes that contribute to the polarization response. This study integrates DCIP with field-scale reactive transport modelling, utilizing both synthetic modelling and field investigations, to assess the ability of surface and cross-hole DCIP to monitor H$_2$S mineral storage at the Nesjavellir study site in Iceland. Two surface DCIP data sets were collected at Nesjavellir, with six months of continuous H$_2$S injection between them. Time-lapse inversions, performed using a novel gridding scheme that accounts for electrode misplacement between the two DCIP surveys, recover no significant IP changes beyond data noise. Interpreting these results alongside the reactive transport results finds that pyrite mineralization during the six-month injection period is too small and too deep to be resolved by surface DCIP time-lapse surveying, highlighting the benefit of a joint geophysical–geochemical interpretation approach. Conversely, joint DCIP-reactive transport synthetic modelling shows the potential of cross-hole DCIP for monitoring long-term H$_2$S mineral storage, provided that data noise is low and sufficient H$_2$S is injected. The reactive transport models also provide insight into the mechanisms contributing to the polarization response, demonstrating that pyrite mineralization is the primary contributor to the polarization response, with minimal contribution from other minerals such as smectites and iron oxides. However, existing petrophysical relationships are simplistic, which adds uncertainty to the interpretation of the DCIP signal and the quantification of pyrite mineralization. Additionally, smectite formation has been shown to decrease both the polarization signals and the quality of the IP data due to its electrically conductive properties. At Nesjavellir, a decrease in the DC resistivity from 1925 to 325 $\Omega$m is observed, attributed to the disposal of warm wastewater. This decrease is identified by comparing resistivity data collected in this study to historical vertical electrical sounding data collected prior to geothermal development. Lastly, petrophysical relationships linking DC resistivity, smectite content and permeability suggest a high basalt fracture permeability of 7.9$\times 10^{-12}$ m$^2$, which agrees with values recovered through flow model calibrations. This result demonstrates the value of geophysical surveying not only for monitoring but also for constraining key parameters in reactive transport simulations.


  • Open Access

    Advanced Monitoring of H2S Injection through the Coupling of Reactive Transport Models and Geophysical Responses

    by Daniel A. Ciraula, Barbara I. Kleine-Marshall, Iwona M. Galeczka, Léa Lévy

    Hydrogen sulfide (H2S), an environmentally harmful pollutant, is a byproduct of geothermal energy production. To reduce the H2S emissions, H2S-charged water is injected into the basaltic subsurface, where it mineralizes to iron sulfides. Here, we couple geophysical induced polarization (IP) measurements in H2S injection wells and geochemical reactive transport models (RTM) to monitor the H2S storage efforts in the subsurface of Nesjavellir, one of Iceland’s most productive geothermal fields. An increase in the IP response after 40 days of injection indicates iron-sulfide formation near the injection well. Likewise, the RTM shows that iron sulfides readily form at circumneutral to alkaline pH conditions, and the iron supply from basalt dissolution limits its formation. Agreement in the trends of the magnitude and distribution of iron-sulfide formation between IP and RTM suggests that coupling the methods can improve the monitoring of H2S mineralization by providing insight into the parameters influencing iron-sulfide formation. In particular, accurate fluid flow parameters in RTMs are critical to validate the predictions of the spatial distribution of subsurface iron-sulfide formation over time obtained through IP observations. This work establishes a foundation for expanding H2S sequestration monitoring efforts and a framework for coupling geophysical and geochemical site evaluations in environmental studies.


  • Time‐Lapse Geophysical Investigation of Geyser Dynamics at Spouter Geyser, Yellowstone National Park: Geyser Dynamics II

    by D. A. Ciraula, B. J. Carr, K. W. W. Sims

    Geysers are unique hydrothermal features, requiring specific geometry, fluid, and vapor input, and heat to produce eruptions. In a geyser eruption, the decompression of superheated hydrothermal fluids results in a conversion of thermal to kinetic energy. Recent studies conclude that a laterally offset cavity structure (bubble trap) plays an integral role in the geyser eruption process. In this second study of Spouter Geyser, Yellowstone National Park (YNP), we build on the geyser structure developed in the first publication and explore how structural components, such as the bubble trap, control eruption dynamics. We utilize time‐lapse electrical resistivity tomography (ERT) and transient electromagnetics (TEM) geophysical methods to track changes in the saturation of conductive hydrothermal fluid and resistive vapor through the eruption cycle. Additionally, we use pressure‐temperature transducer data to measure eruption and recharge durations over the past 23 years at Spouter Geyser, identifying long‐period trends in geyser behavior. The geophysics results support the bubble trap model, capturing an increase in resistivity in the bubble trap structure during the recharge phase interpreted as a vapor saturation increase. The TEM also captures a resistivity increase in the 20–30 m depth interval during the eruption phase, interpreted as a vapor‐dominated “flash eruption zone” where the superheated hydrothermal fluids flash into steam and drive fluid out of this zone during the eruption. From the temperature time‐series detailing 23 years of eruption and recharge durations, we find that eruption durations have remained constant at ∼2 hr while recharge durations have decreased linearly at 6.6 min/year.


  • Geophysical Imaging of the Shallow Geyser and Hydrothermal Reservoir Structures of Spouter Geyser, Yellowstone National Park: Geyser Dynamics I

    by D. A. Ciraula, B. J. Carr, K. W. W. Sims

    Yellowstone National Park (YNP) is home to roughly 500 geysers, making it the most concentrated geyser field in the world. Recent studies exploring the mechanics of geyser eruptions utilizing laboratory models were limited by a lack of knowledge of the subsurface geometry of the geyser features. This study presents results from active hydrogeophysical surveys, including ground penetrating radar, nuclear magnetic resonance (NMR), seismic refraction, electrical resistivity tomography, and transient electromagnetics to image subsurface geyser structure and constrain the geophysical response of the reservoir structure of Spouter Geyser, Yellowstone National Park. Previous geophysical studies on similar geyser systems in Yellowstone characterize the hydrothermal reservoir that supplies the geyser with hydrothermal fluids and vapors as high porosity, low density structures. Whereas our imaging highlights the hydrothermal conduits and reservoir as high resistivity and high velocity structures, interpreted as silica precipitate decreasing the porosity and increasing the bulk modulus (i.e., from unconsolidated media to semi/fully consolidated). Ground penetrating radar identifies sinter thickness around the geyser, NMR provides porosity measurements of the geyser reservoir, and transient electromagnetics maps the depth to the Biscuit Basin Rhyolite bedrock throughout the field site. Electrical resistivity tomography and seismic refraction image the shallow geyser conduit structures to ∼15 m depth and establish the extent of the geyser hydrothermal reservoir structure. Furthermore, a spatial correlation of the electrical resistivity and seismic velocity results establishes the interpreted hydrothermal geyser reservoir as a high resistivity, high velocity structure located to the northeast of Spouter Geyser at depths greater than 15 m.